Z e n i t h ® P u m p s I n s t a l l a t i o n , C a r e a n d M a i n t e n a n c e Z e n i t h P o l y m e r E x t r u s i o n G e a r Pu m p s P E P - I I S e r i e s G e a r P u m p s.
Zenith ® Pumps 2 Thoroughly read and understand this entire manual before installation and operation of pump. Benefits Specifications Capacities: 0.16 to 750 cc/rev . Operating Speed: 10 - 90 rpm on most extrusion processes depending upon process parameters Differential Pressure: Up to 5,000 psi (345 bar) Body Pressure: 10,000 psi (690 bar).
Zenith ® Pumps and The Extrusion Pr ocess Design Zenith Pumps can handle all your extrusion pumping applications including additive injection for on-line compounding of tackifiers, colorants, stabilizers, etc.
PEP-II Pump 0.16-3 cc/r ev ITEM QTY P ART MA TERIAL 1 1 FRONT PLA TE TOOL STEEL 2 1 CENTER PLA TE TOOL STEEL 3 1 REAR PLA TE TOOL STEEL 4 1 DRIVE SHAFT TOOL STEEL 5 1 ARBOR TOOL STEEL 6 2 METERING GEA.
ITEM QTY P ART MA TERIAL 1 1 DRIVING GEAR SHAFT TOOL STEEL 2 1 DRIVEN GEAR SHAFT TOOL STEEL 3 1 CENTER PLA TE TOOL STEEL 4 2 COVER PLA TE 4140 6 2 BEARING TOOL STEEL 7 2 BEARING TOOL STEEL 14 2 SEAL P.
Operation 6 Installation Polymer enters the PEP-II pump on the suction side where shaft r otation exposes gear tooth volumes between the gear teeth. Polymer fills these spaces and is transported to the discharge side where the gear teeth mesh together , decreasing the gear tooth volumes and displacing the polymer .
Cleaning, Inspection, Repair and Service 7 Disassembly After removal fr om the system, the assem- bled pump can be cleaned by placing it in a suitable furnace (i.e. vacuum oven, fluidized bed, etc.) and slowly increasing the temperature to 800-850° F in no less than two hours.
Disassembly continued 8 D-Bearing Orientation Schematic plate and set aside in a safe place to pre- vent damage. At this point, make certain to note the orientation of the groove on the rear of each bearing with r espect to the inlet port.
Reassembly 9 These instructions should be thoroughly read and understood befor e starting reassembly . General instructions that should be observed to ensure corr ect reassembly of the pump are as follows: • Using a solvent such as trichloroethane or chlor oethene Nu, clean all parts that are to be used in the reassembled pump.
Size (UNC Recommended Alloy Steel) T orque (in-lbs) 1/2-13 922 9/16-12 1,331 5/8-11 1,836 3/4-10 3,257 7/8-9 5,800 1-8 8,000 1 1/8-7 12,000 10 Reassembly continued Bolt T or que Size (UNC Recommended .
11 T r oubleshooting Par ts Replacement When ordering r eplacement parts, please be sure to include the following information: 1) Pump model number 2) Part number (12-digit) and description 3) Quantity 4) Shipping instructions Order parts from your local Zenith r epresentative or dir ect from Zenith.
F AILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELA TED ITEMS CAN CAUSE DEA TH, PERSONAL INJURY AND PROPERTY DAMAGE.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Zenith Pumps c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Zenith Pumps - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Zenith Pumps, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Zenith Pumps va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Zenith Pumps, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Zenith Pumps.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Zenith Pumps. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Zenith Pumps ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.