036-21004-002 Re v . B (0602) FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE SPLIT -SYSTEM AIR CONDITIONERS 14 SEER MODELS: FRCS024 THRU 060 (2 THRU 5 NOMINAL TONS) Due to continuo us product impr ovement, specifica tions are subjec t to change without notice .
036-21004-002 Rev. B (0602 ) 2 Unitary Products Group Physical and Electr ical Dat a MODEL FRCS0241BD FRCS0301BD FRCS0361CD FRCS0421CE FRCS0481CE F RCS0601BF Unit Supply V oltage 208 / 230 - 1 – 60 Normal V oltage Range 1 187 to 252 Minimum Circuit Ampacity 12.
036-21004-002 Rev. B (0602) Unitary Products Group 3 - = Not applicable COOLING CAP ACITY - Wi th Air Handler Coils UNIT MODEL AIR HANDLER COIL 1 MODEL COOLING MODEL ELECTRIC 2 HEA T KW W RA TED CFM NET MBH SEER W/O TXV SEER + TXV 3 EER TOT AL SENS. 1 PH 14 SEER AC WITH N-AH / G2FD FRCS0241BD N1AHB0806 2,5,8,10 17 G2FD036S17 800 25.
036-21004-002 Rev. B (0602 ) 4 Unitary Products Group COOLING CAP ACITY - Upflow , Downflow , & Horizont al Furnaces and Coils UNIT MODEL FURNACE** COIL MODEL COOLING CFM RANGE (MIN.-MAX.) W RA TED CFM NET MBH SEER + TXV W/O TDR SEER + TXV 1 + TDR* EER TOT AL S EN S.
036-21004-002 Rev. B (0602) Unitary Products Group 5 * Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up. FRCS0601BF 1650 2150 21,24 G1F A060S21,24 1900 53.
036-21004-002 Rev. B (0602 ) 6 Unitary Products Group 1. For condensing unit only . Does not include ef fe ct of evaporator motor power or heat. 2. Performance based on 1 5° superheat and 1 5° sub-cooling at condensing unit. a. Increa se capacit y 1% for e ach 2° in crease in sub-cool ing.
036-21004-002 Rev. B (0602) Unitary Products Group 7 TYPICAL INST ALLA TION TYPICAL FIELD WIRING MINIMUM 18” SERVICE ACCESS CLEARANCE ON ONE SIDE 60” OVERHEAD CLEARANCE 10” CLEARANCE COIL AREA W.
036-21004-002 Rev. B (0602 ) 8 Unitary Products Group Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO.
036-21004-002 Rev. B (0602) Unitary Products Group 9 Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO.
036-21004-002 Rev. B (0602 ) 10 Unitary Products Group Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO.
036-21004-002 Rev. B (0602) Unitary Products Group 11 Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO.
036-21004-002 Rev. B (0602 ) 12 Unitary Products Group Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO.
036-21004-002 Rev. B (0602) Unitary Products Group 13 Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO.
036-21004-002 Rev. B (0602 ) 14 Unitary Products Group MA TCHING INDOOR COMPONEN TS G1UA 1/2 CASED UPFLOW G1HD HORIZONT AL DUCT G2FD* MUL TI-POSITION (UPFLOW , HORIZONT AL AND DOWNFLOW) * Available with factory installed horizontal drain p an.
036-21004-002 Rev. B (0602) Unitary Products Group 15 NOTES.
Subject to change without notice. Printed in U.S.A. 036-21004-002 Rev. B (0602) Copyright © by York International Corp. 2002. All rights reserved. Supersedes: 036-2100 4-002 Rev.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté York FRCS024 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du York FRCS024 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation York FRCS024, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le York FRCS024 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le York FRCS024, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du York FRCS024.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le York FRCS024. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei York FRCS024 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.