Manuel d'utilisation / d'entretien du produit E4TS030 THRU 060 du fabricant York
Aller à la page of 24
036-21342-002 Rev. E (0505) FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE ® TECHNICAL GUIDE STEAL TH SPLIT -SYSTEM HEAT PUMP 15 SEER MODELS: E4TS 030 THRU 060 (2.5 THRU 5 NOMINAL T ONS) Due to continuous produc t improvement, specifi c tions are subject to chan ge without notice.
036-21342-002 Rev. E (0505 ) 2 Unitary Products Group SYSTEM OPERA TION This heat pump model is equippe d with both Y orkGuard V heat pump control and TS compressor control. The interface control 6CF board is used to bypass the first stage of heat when the outdoor temperature falls below ce rtain tempera- tures.
036-21342-002 Rev. E (0505) Unitary Products Group 3 Physical and Electrical Dat a MODEL E4TS030 E4TS036 E4TS048 E4TS060 UNIT SUPPL Y VOL T AGE 208/230-1-60 NORMAL VOL T AGE RANGE 1 1. Rated in accordance with ARI S tandard 1 10, utilizaton range “A”.
036-21342-002 Rev. E (0505 ) 4 Unitary Products Group 1. Unit factory charge listed on the unit nameplate include s re frigerant for the condensor , the smallest evaporator and for 15 f eet of interconnecting line tubing. 2. V erify the TXV kit and the additional charge required for the s pecific evaporator coil in the system using the table above.
036-21342-002 Rev. E (0505) Unitary Products Group 5 COOLING CAP ACITY - V ariable S peed Air Handler UNIT MODEL N1VS AIR HANDLER COIL MODEL 1 1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number .
036-21342-002 Rev. E (0505 ) 6 Unitary Products Group E4TS036 P1XDB12V 17 G2F D046S17 1 690 20000 15200 14. 0 12.4 2 1220 35600 25800 10.8 P1XUB12V 17 G2FD046S17 1 660 19800 15000 14.0 12.5 2 1200 35400 25600 1 1.0 G1UA048S17 1 660 19800 15000 14. 0 12.
036-21342-002 Rev. E (0505) Unitary Products Group 7 E4TS048 P1XUC16V 21 G1UA060S21 1 880 23800 17600 14.0 12.6 2 1600 47000 33800 10.8 G1UA060S21 1 880 23800 17600 14.0 12.6 2 1600 47000 33800 10.8 P1DUC20V 21 G1UA060S21 1 900 24200 18000 14 .0 12.6 2 1610 47500 34200 10.
036-21342-002 Rev. E (0505 ) 8 Unitary Products Group HEA TING CAP ACITY - V ari able Spe ed Air Handler UNIT MODEL N1VS AIR HANDLER COIL MODEL 1 1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number .
036-21342-002 Rev. E (0505) Unitary Products Group 9 HEA TING CAP ACITY - V ariable Speed Furnace UNIT MODEL V ARIABLE SPEED FURNACE MODEL WC O I L M O D E L HEA TING ST AGE (# CYL) RA TED CFM NET MBH 1,2 HSPF 3 COP 4 @ 47 F 47 OD 17 OD E4TS030 P1XDB12V075 17 G2FD046S17 1 580 12800 - - 3.
036-21342-002 Rev. E (0505 ) 10 Unitary Products Group E4TS036 P1DUB16V080 17 G2FD046S17 1 650 17000 - - 3.54 2 650 31000 18400 8.0 3.30 2 1200 34600 20600 8.4 3.56 G1UA048S17 1 650 17200 - - 3.58 2 650 31400 18600 8.0 3.32 2 1200 35000 20800 8.4 3.58 G1F A048S17 1 650 17200 - - 3.
036-21342-002 Rev. E (0505) Unitary Products Group 11 E4TS036 P1XUC20V095 21 G1UA048S21 1 625 16600 - - 3.48 2 625 31800 18800 7.9 3.34 2 1200 35400 21000 8 .3 3.60 G1F A048S21 1 625 16600 - - 3.48 2 625 31800 18800 7.9 3.34 2 1200 35400 21000 8 .3 3.
036-21342-002 Rev. E (0505 ) 12 Unitary Products Group ACCESSORIES Refer to Price Manual for specific model numbers. TXV Kit - Factory specified and required for p roper unit per- formance.
036-21342-002 Rev. E (0505) Unitary Products Group 13 Multipliers for determining th e performance with other indoor sections . HIGH CFM LOW CFM NOTE: KW RA TING IS FO R OUTDOOR AND INDOOR UNITS.
036-21342-002 Rev. E (0505 ) 14 Unitary Products Group Multipliers for determining th e performance with other indoor sections . HIGH CFM NOTE: KW RA TING I S FOR OUTDOOR AND INDOOR UNITS.
036-21342-002 Rev. E (0505) Unitary Products Group 15 Multipliers for determining th e performance with other indoor sections . LOW CFM NOTE: KW RA TING IS FO R OUTDOOR AND INDOOR UNITS.
036-21342-002 Rev. E (0505 ) 16 Unitary Products Group Multipliers for determining th e performance with other indoor sections . HIGH CFM LOW CFM NOTE: KW RA TING I S FOR OUTDOOR AND INDOOR UNITS.
036-21342-002 Rev. E (0505) Unitary Products Group 17 Multipliers for determining th e performance with other indoor sections . HIGH CFM LOW CFM NOTE: KW RA TING IS FO R OUTDOOR AND INDOOR UNITS.
036-21342-002 Rev. E (0505 ) 18 Unitary Products Group For notes see Page 1 1. Multipliers for determining th e performance with other indoor sections .
036-21342-002 Rev. E (0505) Unitary Products Group 19 For notes see Page 1 1. Multipliers for determining th e performance with other indoor sections .
036-21342-002 Rev. E (0505 ) 20 Unitary Products Group For notes see Page 1 1. Multipliers for determining th e performance with other indoor sections .
036-21342-002 Rev. E (0505) Unitary Products Group 21 For notes see Page 1 1. Multipliers for determining th e performance with other indoor sections .
036-21342-002 Rev. E (0505 ) 22 Unitary Products Group For notes see Page 1 1. Multipliers for determining th e performance with other indoor sections .
036-21342-002 Rev. E (0505) Unitary Products Group 23 MA TCHING INDOOR COMPONENTS G1UA UPFLOW G2FD* MUL TI-POSITION (UPFLOW , HORIZONT AL AND DOWNFLOW) G1F A FULL CASED AIR HANDLERS - FOR NON-FURNACE .
Subject to change without notice. Printed in U .S.A. 036-21342-002 Rev. E (0505) Copyright © by Y ork International Corp. 2005. All rights reser ved. Supersedes: 036-21342-002 Rev .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté York E4TS030 THRU 060 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du York E4TS030 THRU 060 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation York E4TS030 THRU 060, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le York E4TS030 THRU 060 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le York E4TS030 THRU 060, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du York E4TS030 THRU 060.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le York E4TS030 THRU 060. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei York E4TS030 THRU 060 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.