Manuel d'utilisation / d'entretien du produit D*V du fabricant York
Aller à la page of 25
D*V Model Air Cooled Self Contained Indoor Packaged Units 2-25 Tons Preliminary Application Data July 28, 2008 Page 1.
DESCRIPTION: PROJECT: TAG: DATE: Gross Cooling Ca pa city [Btuh] : 95,000* Design CFM: 3,200 Energy Efficiency Ratio : 11.55 EER** Net Cooling Capacity [Btuh] : 92,000** Net Cooling CFM: 3,200 Refrigerant : R22 Charge : 8.75 Lbs./ circuit Compre ss or No.
DATE: DESCRIPTION: "DPV" SERIES VER TICAL INDOOR SYSTEM GENERAL MECHANICAL SPECIFICATIONS GENERAL All models 5-15 tons ship as facto ry-charged unitized packages. The 20 ton model shall be shipped as separate eva po rator and condensing unit modules (nitrogen holdi ng charge only).
DATE: DESCRIPTION: Am bient Condense r Air Tempe r atu re F ° 5 9 F ° 5 8 B W E B W E 62° F 67° F 72° F 62° F 67°F 72° F CFM EDB TC SC TC SC TC SC TC SC TC SC TC SC 75° F 90. 0 72. 0 97. 5 57. 3 106. 7 43. 8 86. 8 70. 6 94. 1 55. 9 102. 5 42.
March 2008 DIMENSIONAL DATA DPV096 & DPV120 VERTICAL UNIT AIR-COOLED SELF-CONTAINED Form YK145.12-PA4 (308) 4 of 4 DPV096 AND DPV120 DIMENSIONAL DA T A Page 5.
DESCRIPTION: PROJECT: TAG: DATE: Gross Cooling Ca pa city [Btuh] : 122,000* Design CFM: 4,000 Energy Efficiency Ratio : 10.60 EER** Net Cooling Capacity [Btuh] : 117,000** Net Cooling CFM: 3,600 Refrigerant : R22 Charge : 9.5 Lbs./ circuit Compre ss or No.
DATE: DESCRIPTION: "DPV" SERIES VER TICAL INDOOR SYSTEM GENERAL MECHANICAL SPECIFICATIONS GENERAL All models 5-15 tons ship as facto ry-charged unitized packages. The 20 ton model shall be shipped as separate eva po rator and condensing unit modules (nitrogen holdi ng charge only).
DATE: DESCRIPTION: Am bient Condense r Air Tempe r atu re F ° 5 9 F ° 5 8 10 TON B W E B W E 62° F 67° F 72° F 62° F 67°F 72° F CFM EDB TC SC TC SC TC SC TC SC TC SC TC SC 75° F 115. 4 91. 5 124. 8 73. 0 134. 5 53. 8 111. 0 89. 6 120. 2 71. 1 129.
March 2008 DIMENSIONAL DATA DPV096 & DPV120 VERTICAL UNIT AIR-COOLED SELF-CONTAINED Form YK145.12-PA5 (308) 4 of 4 DPV096 AND DPV120 DIMENSIONAL DA T A Page 9.
DESCRIPTION: PROJECT: TAG: DATE: Gross Cooling Ca pa city [Btuh] : 150,000* Design CFM: 4,800 Energy Efficiency Ratio : 10.65 EER** Net Cooling Capacity [Btuh] : 144,000** Net Cooling CFM: 4,800 Refrigerant : R22 Charge : 12.13 Lbs./ circuit Compre ss or No.
DATE: DESCRIPTION: "DPV" SERIES VER TICAL INDOOR SYSTEM GENERAL MECHANICAL SPECIFICATIONS GENERAL All models 5-15 tons ship as facto ry-charged unitized packages. The 20 ton model shall be shipped as separate eva po rator and condensing unit modules (nitrogen holdi ng charge only).
DATE: DESCRIPTION: Am bient Condense r Air Tempe r atu re F ° 5 9 F ° 5 8 12 TON B W E B W E 62° F 67° F 72° F 62° F 67°F 72° F CFM EDB TC SC TC SC TC SC TC SC TC SC TC SC 75° F 140. 0 108. 7 151. 6 87. 4 167. 1 66. 6 135. 4 106. 7 146. 6 85.
DPV144 DPV180 March 2008 DIMENSIONAL DATA DPV144 & DPV180 VERTICAL UNIT AIR-COOLED SELF-CONTAINED Form YK145.12-PA6 (308) 4 of 4 DPV0144 AND DPV180 DIMENSIONAL DA T A Page 13.
DESCRIPTION: PROJECT: TAG: DATE: Gross Cooling Ca pa city [Btuh] : 186,000* Design CFM: 6,000 Energy Efficiency Ratio : 9.80 EER** Net Cooling Capacity [Btuh] : 178,000** Net Cooling CFM: 5,500 Refrigerant : R22 Charge : 13.83 Lbs./ circuit Compre ss or No.
DATE: DESCRIPTION: "DPV" SERIES VER TICAL INDOOR SYSTEM GENERAL MECHANICAL SPECIFICATIONS GENERAL All models 5-15 tons ship as facto ry-charged unitized packages. The 20 ton model shall be shipped as separate eva po rator and condensing unit modules (nitrogen holdi ng charge only).
DATE: DESCRIPTION: Am bient Condense r Air Tempe r atu re F ° 5 9 F ° 5 8 15 TON B W E B W E 62° F 67° F 72° F 62° F 67°F 72° F CFM EDB TC SC TC SC TC SC TC SC TC SC TC SC 75° F 175. 4 138. 5 189. 7 110. 0 207. 4 82. 9 168. 8 135. 5 182. 8 107.
DPV144 DPV180 March 2008 DIMENSIONAL DATA DPV144 & DPV180 VERTICAL UNIT AIR-COOLED SELF-CONTAINED Form YK145.12-PA7 (308) 4 of 4 DPV144 AND DPV180 DIMENSIONAL DA T A Page 17.
DESCRIPTION: PROJECT: TAG: DATE: Gross Cooling Ca pa city [Btuh] : 244,000* Design CFM: 8,000 Energy Efficiency Ratio : 10.10 EER** Net Cooling Capacity [Btuh] : 236,000** Net Cooling CFM: 6,800 Refrigerant : R22 Charge : 18.35 Lbs./ circuit Compre ss or No.
DATE: DESCRIPTION: "DPV" SERIES VER TICAL INDOOR SYSTEM GENERAL MECHANICAL SPECIFICATIONS GENERAL All models 5-15 tons ship as facto ry-charged unitized packages. The 20 ton model shall be shipped as separate eva po rator and condensing unit modules (nitrogen holdi ng charge only).
DATE: DESCRIPTION: Am bient Condense r Air Tempe r atu re F ° 5 9 F ° 5 8 20 TON B W E B W E 62° F 67° F 72° F 62° F 67°F 72° F CFM EDB TC SC TC SC TC SC TC SC TC SC TC SC 75° F 230. 3 184. 1 248. 7 146. 4 269. 3 108. 2 221. 9 180. 3 239. 8 142.
March 2008 DIMENSIONAL DATA DPV240 VERTICAL UNIT AIR-COOLED SELF-CONTAINED Form YK145.12-PA8 (308) 4 of 4 DPV240 DIMENSIONAL DA T A Page 21.
DESCRIPTION: PROJECT: TAG: DATE: Gross Cooling Ca pa city [Btuh] : 304,000* Design CFM: 10,000 Energy Efficiency Ratio : 9.60 EER** Net Cooling Capacity [Btuh] : 286,000** Net Cooling CFM: 8,800 Refrigerant : R22 Charge : 14.65 Lbs./ circuit Compre ss or No.
DATE: DESCRIPTION: "DPV" SERIES VER Johnson Controls maintains a continuous product improvement policy, t he refore specifications are subject to change without noti ce. March 2008 MECHANICAL SPECIFICATIONS DPV300 VERTICAL UNIT AIR-COOLED SELF-CONTAINED Form YK145.
DATE: DESCRIPTION: Am bient Condense r Air Tempe r atu re F ° 5 9 F ° 5 8 25 TON B W E B W E 62° F 67° F 72° F 62° F 67°F 72° F CFM EDB TC SC TC SC TC SC TC SC TC SC TC SC 75° F 285. 6 225. 4 308. 9 180. 1 339. 4 136. 0 275. 0 220. 8 297. 5 175.
March 2008 DIMENSIONAL DATA DPV300 VERTICAL UNIT AIR-COOLED SELF-CONTAINED Form YK145.12-PA9 (308) 4 of 4 DPV300 DIMENSIONAL DA T A Page 25.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté York D*V c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du York D*V - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation York D*V, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le York D*V va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le York D*V, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du York D*V.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le York D*V. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei York D*V ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.