036-21508-005-A-03 05 FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE SINGLE P ACKAGE HEAT PUMP UNITS BQ 036, 048 & 060 3, 4 & 5 NOMINAL TONS 10.
036-21508-005-A-03 05 2 Unitary Products Group T ABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 PRODUCT NOMENCLATURE . . . . . . . . . . . . . . . . . . . 3 FEATURES . . . . . . . . . . . . . . . . . . . . . .
036-21508-005-A-0305 Unitary Products Group 3 PRODUCT NOMENCLA TURE.
036-21508-005-A-03 05 4 Unitary Products Group PRODUCT NOMENCLA TURE - Continued 3-6T Sunline Model Number Nome nclature S t andard Ca binet AA None AB Phase Monitor AC C oil Guard AD Dirty Filter Swi.
036-21508-005-A-0305 Unitary Products Group 5 JR Johnson UNT Controller , DFS, APS, T echnicoat Evap. & Cond Coils, Phase Monitor , & Coil Guard JS Johnson UNT Controller , DFS, APS, SS Drain .
036-21508-005-A-03 05 6 Unitary Products Group TD T echnicoat Condenser Coil & Dirty Filter Switch TE T echnicoat Condenser Coil, P hase Monit or , & Coil Guard TF T echnicoat Condenser Coil, .
036-21508-005-A-0305 Unitary Products Group 7 WF Intelli-Comfort w/Mod Link Controller , T echnicoat Cond. Coil, & Phase Monitor WG Intelli-Comfort w/Mod Link Controller , T echnicoat Cond. Coil, & Coil Guard WH Intelli-Comfort w/Mod Link Controller , T echni coat Cond.
036-21508-005-A-03 05 8 Unitary Products Group DX CPC Controller , DFS, APS, SS Drain Pan, Phase Monitor , Coil Guard, & T echnico at Evap and Cond Coils Hinged Filter Door & T ool less Access.
036-21508-005-A-0305 Unitary Products Group 9 PC Novar ETC-3 Controller , DFS, APS & Coil Guard, Hinged Filter Door & T oolless Access Panels PD Novar ETC-3 Controller , DFS, APS, Phase Monitor , & Co il Guard, Hinged Filter Door & T oolless Access Panels PE Novar ETC-3 Controller , DFS, APS & T echnicoat Cond.
036-21508-005-A-03 05 10 Unitary Products Group QD Simplicity Intelli-Comfort Controller , Phase Monitor , & Coil Guard, Hinged Filter Door & T oolless Access Panels QE Simplicity Intelli-Comfort Controller , & T echnicoat Cond.
036-21508-005-A-0305 Unitary Products Group 11 FEA TURES All models are available with a wide variety of factory- mounted options such as electric heaters, phase monitor , convenience outlet, dirty filter switch, discon nect switch, smoke detectors, and coil guards to make them suitable for almost every application.
036-21508-005-A-03 05 12 Unitary Products Group F ACTOR Y -INST ALLED OPTIONS • SINGLE INPUT ELECTR ONIC ENTHALPY ECONO- MIZERS - Includes a slide-in / plug-in damper assemb ly with fully modulating spring-return motor actuator capa- ble of introducing up to 100% outdoor air with nominal 1% leakage type dampers.
036-21508-005-A-0305 Unitary Products Group 13 Air IAQ sensor . Construction mode operation, 365-da y real time clock with 7 day programming plus holiday scheduling is built-in. T wo different modes of de mand ventilation are achieved th roug h th e INTELLI-Com- fort™using CO2 sensors.
036-21508-005-A-03 05 14 Unitary Products Group Roof curbs are designed to fit inside the base rails of the unit and include both a wood naili ng strip and duct hanger supports. • POWER EXHAUST - Our single input economizer options are available w ith power exhaust.
036-21508-005-A-0305 Unitary Products Group 15 T ABLE 1: S OUND POWER RA TING 1 UNIT SIZE CFM ESP BLOWER SOUND POWER (db 10 -12 Wat ts ) Octave Band Centerline Frequency (Hz) SWL dB(A) dB(A) @ 10Ft. 2 IWG SPEED KW 63 125 250 500 1,000 2,000 4,000 8,000 036 1,200 0.
036-21508-005-A-03 05 16 Unitary Products Group T ABLE 3: B Q036 COOLING CAP ACITIE S (3 TON) CFM WB °F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 72 51 3.4 37 32 28 24 19 - - 47 3.7 34 29 25 22 17 - - 67 46 3.4 40 40 36 31 26 21 16 44 3.7 38 38 34 29 24 20 15 62 42 3.
036-21508-005-A-0305 Unitary Products Group 17 T ABLE 4: B Q048 COOLING CAP ACITIE S (4 TON) CFM WB °F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 72 56 4.1 42 36 31 26 - - - 53 4.5 40 35 29 24 - - - 67 53 4.0 48 47 41 36 30 25 - 51 4.4 46 45 41 35 30 24 - 62 49 4.
036-21508-005-A-03 05 18 Unitary Products Group T ABLE 5: BQ060 COOLING CAP ACITIES (5 T ON) CFM WB °F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 72 68 5.7 51 44 38 31 - - - 67 6.0 51 45 38 31 - - - 67 65 5.6 58 56 50 43 37 30 - 64 5.9 56 56 50 43 37 30 - 62 61 5.
036-21508-005-A-0305 Unitary Products Group 19 T ABLE 6: B Q HEA TING CA P ACITIE S CAP & K W - 1 0 0 1 02 03 04 05 06 0 MBH 13.1 16.4 23.5 29.1 30.2 41.7 47 48.2 KW 2.9 3 3.2 3.3 3.5 3.7 3.8 3.9 MBH 11.9 15 21.5 26.7 27.7 38.2 43.1 44.1 KW 3 3.1 3.
036-21508-005-A-03 05 20 Unitary Products Group T ABLE 7: SUPPLY AIR BLOWER PERFORMANCE (3 TON BELT DRIVE) - SIDE DUCT A PPLICATION RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATT.
036-21508-005-A-0305 Unitary Products Group 21 T ABLE 8: S UPPLY AIR BLOWER PERFORMANCE (4 TON BELT DRIVE) - SIDE D UCT APPLICATION RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATT.
036-21508-005-A-03 05 22 Unitary Products Group T ABLE 9: SUPPLY AIR BLOWER PERFORMANCE (5 TON BELT DRIVE) - SIDE DUCT A PPLICATION RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATT.
036-21508-005-A-0305 Unitary Products Group 23 T ABLE 10: SUP PLY AIR BLOWER PERFORMANCE (3 - 5 T ON DIRECT DRIVE) - SID E DUCT APPLICATION CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS HI ------ .
036-21508-005-A-03 05 24 Unitary Products Group T ABLE 12: ST A TIC RESIST ANCES T ABLE 13: ELECTRIC HE A TER CFM LIMIT A TIONS 1000 1200 1400 1600 1800 2000 2200 2400 2600 0.07 0.08 0.09 0.11 0.13 0.15 0.17 0.20 0.23 5-15KW 0.04 0.05 0.06 0.07 0.08 0.
036-21508-005-A-0305 Unitary Products Group 25 T ABLE 14: ELECTRICAL DATA - BQ036 & 04 8 DIRE CT DRIVE WITHOUT POWR ’D CONVENIENCE OUTLET NONE 0.0 29.9 45 2CE04510506 4.0 0.0 19.2 53.9 60 2CE04510706 5.6 26.9 63.5 70 2CE04511006 8.0 38.5 77.9 80 2CE04511506 11.
036-21508-005-A-03 05 26 Unitary Products Group T ABLE 15: ELECTRICAL DAT A - BQ060 DIRECT DRIVE WITHOUT POWR ’D CONVENIENCE OUTLET NONE 0.0 0.0 49.0 80 2CE04510506 4.0 19.2 73.1 100 2CE04510706 5.6 26.9 82.7 100 2CE04511006 8.0 38.5 97.1 110 2CE04511506 11.
036-21508-005-A-0305 Unitary Products Group 27 T ABLE 16: ELECTRICAL DATA - BQ036 & 04 8 BE LT DRIVE WITHOUT POWR ’D CONVENIENCE OUTLET NONE 0.0 33.0 50 2CE04510506 4.0 19.2 57.1 70 2CE04510706 5.6 26.9 66.7 70 2CE04511006 8.0 38.5 81.1 90 2CE04511506 11.
036-21508-005-A-03 05 28 Unitary Products Group T ABLE 17: ELECTRICAL DATA - BQ060 BELT DRIVE WITHOUT POW R ’D CONVENIENCE OUTLET NONE 0.0 0.0 50.0 80 2CE04510506 4.0 19.2 74.1 100 2CE04510706 5.6 26.9 83.7 100 2CE04511006 8.0 38.5 98.1 110 2CE04511506 11.
036-21508-005-A-0305 Unitary Products Group 29 T ABLE 18: ELECTRICAL DATA - BQ036 & 04 8 DI RECT DRIVE WITH POW R ’D CONVENIENCE OUTLE T NONE 0.0 39.8 50 2CE04510506 4.0 19.2 63.9 70 2CE04510706 5.6 26.9 73.5 80 2CE04511006 8.0 38.5 87.9 90 2CE04511506 11.
036-21508-005-A-03 05 30 Unitary Products Group T ABLE 19: ELECTRICAL D AT A - BQ060 DIRE CT DRIVE WITH POWR ’D CONV ENIENCE OUTLET NONE 0.0 0.0 59.0 90 2CE04510506 4.0 19.2 83.1 110 2CE04510706 5.6 26.9 92.7 110 2CE04511006 8.0 38.5 107.1 125 2CE04511506 11.
036-21508-005-A-0305 Unitary Products Group 31 T ABLE 20: ELECTRICAL DATA - BQ036 & 04 8 BELT DRIVE WITH POWR ’D CONVENIENCE OUTLE T NONE 0.0 43.0 60 2CE04510506 4.0 19.2 67.1 80 2CE04510706 5.6 26.9 76.7 80 2CE04511006 8.0 38.5 91.1 100 2CE04511506 11.
036-21508-005-A-03 05 32 Unitary Products Group T ABLE 21: ELECTRICAL DATA - BQ060 BELT DRIVE WITH POWR ’D CONVENIENCE OUTLET NONE 0.0 0.0 60.0 90 2CE04510506 4.0 19.2 84.1 110 2CE04510706 5.6 26.9 93.7 110 2CE04511006 8.0 38.5 108.1 125 2CE04511506 11.
036-21508-005-A-0305 Unitary Products Group 33 T ABLE 22: PHY SICAL DATA MODELS BQ 036 048 060 EV APORA TOR BLOWER Centrifug al Blower (Dia . x Wd. in.) 12 X 10 12 X 10 12 X 10 Fan Motor HP (Dire c t Dri ve ) 1/2 3/4 1 Fan Motor HP (Bel t Drive) 1 1/2 1 1/2 1 1/2 EV APORA TOR COIL Rows Deep 4 3 3 Fins Per In ch 16 15 15 Face Area (S q.
036-21508-005-A-03 05 34 Unitary Products Group TYPICAL POWER WIRING TYPICAL CONTROL WIRING FIGURE 2 - TYPICAL FIELD POWER & CONTROL WIRING REFER TO THE ELECTRICAL D A T A T ABLES T O SIZE T HE DISCONNECT SWITCH, O VERCURRENT PRO TEC- TION AND WIRING.
036-21508-005-A-0305 Unitary Products Group 35 FIGURE 3 - UNIT DIMENSIONS (3 - 5 TON HEA T PUMP) FRONT VIEW FIGURE 4 - UNIT WITH ECONOMIZER RAI NHOOD DETAIL “A”.
036-21508-005-A-03 05 36 Unitary Products Group FIGURE 5 - UNIT WITH FIXED OUTDOO R AIR/MOTORIZED DAMPER RAINHOOD DETAIL “B” FIGURE 6 - UNIT DIMENSIONS (REAR VIEW ).
036-21508-005-A-0305 Unitary Products Group 37 FIGURE 7 - DISCONNECT/BLOWER ACCESS LOCA TION DISCONNECT SWITCH LOCATION AND MO TOR ACCESS PANEL FOR UNIT W ITH “BELT-DRIVE” OPT ION CONTROL BOX ACCE.
036-21508-005-A-03 05 38 Unitary Products Group FIGURE 8 - TYPICAL APPLICA TIONS.
036-21508-005-A-0305 Unitary Products Group 39 FIGURE 9 - FOUR AND SIX POINT LOADING 44 7 / 8 82 1 / 4 Y X A B C D CONDENSER COIL END OF UNIT FRONT OF UNIT APPROXIMATE CENTER OF GRAVITY BACK OF UNIT 4.
036-21508-005-A-03 05 40 Unitary Products Group GUIDE SPECIFICA TIONS GENERAL Units shall be manufactured by Y ork International Unitary Products Group in an ISO 9001 certified facility . Y ork's Sunline 2000 TM units are convertible single package heat pumps.
036-21508-005-A-0305 Unitary Products Group 41 lated with a mini mum 1/2” thi ck insulati on, coated on the air- side. Aluminum foil face d insulation shal l be used in the furnace compartment and be fa stened with ridged fasteners to prevent insulation fro m ente ring the air stream.
036-21508-005-A-03 05 42 Unitary Products Group matic reset to prevent the heating element syste m from oper- ating at an excessive temperature. The heating section assembly shall slide out o f the unit for easy main tenance and service.
036-21508-005-A-0305 Unitary Products Group 43 • BAS CONTROLS ( SImplic ity ™ INTELLI-Comfort™ , CPC, JOHNSON, HONEYWELL, NOV AR) • BAS READY ECONOMIZER (BELIMO ACTUA TOR WITHOUT A CONTROLLER).
Subject to change without notice. Printed in U.S.A. 036-21508-005-A-0305 Copyright © 2005 by Unitary Products Group. All ri ghts reserved. Supersedes: 036-21508-004-A-0504 Unitary 5005 Norman Product.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté York BQ 060 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du York BQ 060 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation York BQ 060, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le York BQ 060 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le York BQ 060, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du York BQ 060.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le York BQ 060. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei York BQ 060 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.