036- 21528-001- A-0303 FOR DISTRIBUTION USE ONL Y - NOT TO BE USED A T POINT OF RET AIL SALE ® CHAMPIONÆ PLUS SINGLE PACKAGE HEAT PUMPS B1HP024 THRU 0 48 2 THRU 4 NOMINAL TONS 13 SEER FACTORY MOUNTED TXV DESCRIPTION These package d heat pump s are desi gned for outdoor instal lation.
036-215 28-001- A-0303 2 Unitary Products G roup CONDENSA TE P AN A non-corrosiv e, long-lasting, wate r-tight pan is posi- tioned bel ow the evapo rator coil to collect and drain all conde nsate; less collectio n of st agnate con densate wi ll build-u p.
0 3 6 - 2 1 5 2 8 - 0 0 1 - A - 0 3 0 3 Unitary Products G roup 3 PROTECTED COMPRESSOR The compr ess or is i nternal ly prote cted agai nst high pressu re and temp erature.
036-215 28-001-A-0303 4 Unitary Products G roup RECT ANGLE TO ROUND ADAPTE RS Kit inc ludes one s upply a nd one retur n air rect angle to round d uct adapte r. Adapters a re prefo rmed and design ed to fit over current duc t openings o n the base unit .
0 3 6 - 2 1 5 2 8 - 0 0 1 - A - 0 3 0 3 Unitary Products G roup 5 SEER = Seasonal Ene rgy Efficiency Ratio - the total cool ing output in B TU's during a normal ann ual usage pe riod for c ooling divi d ed by the total el ectric power inpu t in watt-hours during the same period.
036-215 28-001-A-0303 6 Unitary Products G roup T ABLE 3: COOLING CAP ACITIES - 2 TON (BHP0 24) TEMPERA T URE AIR ON OUTDOOR COIL TEMPERA TURE OF AIR O N INDOOR COIL 800 CF M 900 C FM WB ∞ FW B ∞ F 72 67 6 2 57 72 67 62 57 85 ∞ F NET CA P . MBH 29.
0 3 6 - 2 1 5 2 8 - 0 0 1 - A - 0 3 0 3 Unitary Products G roup 7 T ABLE 4: COOLING C AP ACITIES - 2-1/2 T ON (BHP030) TEMPERA T URE AIR ON OUTDOOR COIL TEMPERA TURE OF AIR ON INDOOR COIL 1000 CFM 1 1 25 CFM WB ∞ FW B ∞ F 72 67 62 57 72 67 62 57 85 ∞ F NET CA P .
036-215 28-001-A-0303 8 Unitary Products G roup T ABLE 5: COOLING CAP ACITIES - 3 TON (BHP0 36) TEMPERA T URE AIR ON OUTDOOR COIL TEMPERA TURE OF AIR ON INDOOR COIL 1050 CFM 1200 CFM WB ∞ FW B ∞ F 72 67 62 57 72 67 62 57 85 ∞ F N E T C A P . M B H 4 1 .
0 3 6 - 2 1 5 2 8 - 0 0 1 - A - 0 3 0 3 Unitary Products G roup 9 T ABLE 6: COOLING C AP ACITIES - 3-1/2 T ON (BHP042) TEMPERA T URE AIR ON OUTDOOR COIL TEMPERA TURE OF AIR ON INDOOR COIL 1300 CFM 1400 CFM WB ∞ FW B ∞ F 72 67 62 57 72 67 62 57 85 ∞ F NET CA P .
036-215 28-001-A-0303 10 Unitary Products G roup T ABLE 7: COOLING CAP ACITIES - 4 TON (BHP0 48) TEMPERA T URE AIR ON OUTDOOR COIL TEMPERA TURE OF AIR ON INDOOR COIL 1500 CFM 1600 CFM WB ∞ FW B ∞ F 72 67 62 57 72 67 62 57 85 ∞ F N E T C A P . M B H 5 4 .
0 3 6 - 2 1 5 2 8 - 0 0 1 - A - 0 3 0 3 Unitary Products G roup 11 T ABLE 8: HEA TING CAP ACITI ES - 2 TON (BHP024) CFM RETURN AIR ∞ F CAP 1 & KW OUTDOOR AIR TE MPERA TURE, ∞ F (72% RH) -10 0 10 20 30 40 50 60 600 55 MBH 10.216 1 1.748 13.601 1 5.
036-215 28-001-A-0303 12 Unitary Products G roup T ABLE 10: HE A TING CAP ACITIES - 3 TON (BHP036) CFM RETURN AIR ∞ F CAP 1 & KW OUTDOOR AIR TEM PERA TURE, ∞ F (72% RH) -10 0 10 20 30 40 50 60 900 55 MBH 10.597 12.792 15.4 48 18.660 22.54 5 27.
0 3 6 - 2 1 5 2 8 - 0 0 1 - A - 0 3 0 3 Unitary Products G roup 13 T ABLE 12: HE A TING CAP ACITIES - 4 TON (BHP0 48) CFM RETURN AIR ∞ F CAP 1 & KW OUTDOOR AIR TEM PERA TURE, ∞ F (72% RH) -10 0 10 20 30 40 50 60 1200 55 MBH 13.911 17. 096 21.021 25.
036-215 28-001-A-0303 14 Unitary Products G roup NOTE: Above da ta includes allowances for a dry i ndoor coil a nd no fil ters. For add itional pr essure dr ops, refer to the ì Additi on al Static Pressure Resistanceî table. T ABLE 13: SI DE & BOTTOM SUPPLY AIR BLOWE R PERFORMANCE (208/230/460 VOLT 1 ) MODEL NO.
0 3 6 - 2 1 5 2 8 - 0 0 1 - A - 0 3 0 3 Unitary Products G roup 15 FIGURE 2 - FIELD W IRING DIAGRAM R G W R C Y Y W2 C W1 O O G THERMOST A T UNIT TERMINAL STRIP * ** ** = Minimum wire size of 18 AWG wire should be used for all field installed 24 volt wire.
036-215 28-001-A-0303 16 Unitary Products G roup T ABLE 15: ELECTRICAL DA T A (BASIC UNIT) MODEL BHP POWER SUPPL Y V O LTA G E LIMIT A TIONS 1 COMPRESSOR OUTDOOR FA N MOTOR, FLA SUPPL Y AIR BLOWER MOTOR, FLA MINIMUM CIRCUIT AMP ACITY MAX FUSE SIZE, AMPS 2 MAX.
0 3 6 - 2 1 5 2 8 - 0 0 1 - A - 0 3 0 3 Unitary Products G roup 17 * KW listed is for 240 volts, use T a ble 15 for 208 or 23 0 volts. ** KW listed is fo r 480 volts, use T able 1 5 for 460 volts.
036-215 28-001-A-0303 18 Unitary Products G roup T ABLE 17: APPLICA TION DA T A MODEL BHP 024 030 036 042 048 MINIMU M AIR FL OW (CFM) COOLING 8 00 1 000 1050 1 300 1500 HEA TIN G 800 1000 1050 1 400 .
0 3 6 - 2 1 5 2 8 - 0 0 1 - A - 0 3 0 3 Unitary Products G roup 19 FIGURE 5 - UNIT DIME NSIONS.
036-215 28-001-A-0303 20 Unitary Products G roup FIGURE 6 - TYPICAL A PPLICA TIONS.
0 3 6 - 2 1 5 2 8 - 0 0 1 - A - 0 3 0 3 Unitary Products G roup 21 FIGURE 7 - ROOF CURB DIME NSIONS.
036-215 28-001-A-0303 22 Unitary Products G roup FIGURE 8 - TYPICAL W IRING DIAGRAM (208/230-1-60 POWER SUPPLY).
0 3 6 - 2 1 5 2 8 - 0 0 1 - A - 0 3 0 3 Unitary Products G roup 23 FIGURE 9 - TYP ICAL WIRING DIAGRAM (230-3-60 PO WER SUPPLY).
036-215 28-001-A-0303 24 Unitary Products G roup FIGURE 10 - TYPICAL W IRING DIAGRAM (460-3-60 POWER SUPPLY).
0 3 6 - 2 1 5 2 8 - 0 0 1 - A - 0 3 0 3 Unitary Products G roup 25 MECHANICAL SP ECIFICATIONS GENERAL DESC RIPTION Units sh all be fac tory-assem bled, si ngle pac kaged, Heat Pu mps, design ed for outdoo r mounted installa- tion. Units shall have minimu m SEER rating s of 13.
036-215 28-001-A-0303 26 Unitary Products G roup B. Shall have i nternal is olation and sou nd muffling to minim i ze v ibration and noise, a nd be extern ally iso- lated on a dedicated , indep enden t mountin g.
0 3 6 - 2 1 5 2 8 - 0 0 1 - A - 0 3 0 3 Unitary Products G roup 27.
Subject to change without notice. Printed i n U.S.A. CD: 6-215 28 036-215 28-001-A-0303 Copyri ght © by U nita ry Products Group 2003. All rights reserv ed.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté York B1HP024 THRU 048 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du York B1HP024 THRU 048 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation York B1HP024 THRU 048, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le York B1HP024 THRU 048 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le York B1HP024 THRU 048, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du York B1HP024 THRU 048.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le York B1HP024 THRU 048. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei York B1HP024 THRU 048 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.