ITW Food Equipment Group, LLC 3600 North Point Blvd. Baltimore, MD 21222 FORM F-36986 (Rev . 11-0 8) SERVICE MANUAL Heavy Duty Gas Griddles MODEL MLS 24RRG ML-135339-00024 36RRG ML-135340-00036 48RRG ML-135341-00048 60RRG ML-135342-00060 www.vulcanhart.
- 2 - TABLE OF CONTENTS INSTALLATION………………… …………………………… ………….. OPERATION……………………… ………………………… …………... CLEANING……………………… …………………………… ………….
- 3 - BURNER…………………………… …………………………………….. BURNER TROUBLESHOOTING …………… …………………………. BURNER REMOVAL ………………………… …………………………. BURNER ADJUSTMENT …………………………………… ………….
- 4 - GENERAL INTRODUCTION This manual is prepared for the use of trained service technicians and should only be used by those who are properly qualified.
- 5 - COMPONENT LOCATION TEMPERATURE CONTROLLER 498438 SAFETY IGNITION MODULE 498443 DUAL SOLENOID VA LVE 713656 GAS MANIFOLD 720122 PILOT SPARK ASSEMBLY 713930 INDICATOR LIGHT 720017 POWER SWITCH 810.
- 6 - EXTERIOR PANELS CONTROL PANEL Disconnect the electrical power and follow lockout / tagout procedures The Control Panel holds the thermostats, indicator lights and power switch. REMOVAL 1. Remove the four screws securing the front of the control panel.
- 7 - THERMOSTAT The thermostat is a solid state control. The thermostat supplies power to the burner solenoid valves and indicator lights when turned on or until the temperature setpoint is r eached. Disconnect the electrical power and follow lockout / tagout procedures THERMOSTAT TROUBLESHOOTING SYMPTOM – BURNER WILL NOT COME ON 1.
- 8 - Disconnect the electrical power and follow lockout/tagout procedures THERMOSTAT REMOVAL 1. Remove the control panel 2. Remove the knob 3. Label and disconnect the wires 4. Remove the thermostat retaining nut on the knob shaft. 5. Reverse procedure to install while being careful to install the thermostat in the same orientation.
- 9 - ADJUSTMENTS CALIBRATION 1. Each temperature controller c ontrols a 12” zone of the gri ddle. Using a Surface Probe temperature measurement device, observe the temperatur es at the cente r points of t he cooking zone s.
- 10 - POWER ON/OFF SWITCH The Power Switch controls the power supply to all other electronic com ponents. Disconnect the electrical power and follow lockout / tagout procedures POWER SWITCH TROUBL ESHOOTING SYMPTOM – NO POWER BEING SUPPLIE D TO THE UNIT 1.
- 11 - INDICATOR LIGHT The indicator light illuminates fully to indicate that the corresponding ther mostat and burner have turned on and gas is flowing through the corresponding solenoid valve.
- 12 - Disconnect the electrical power and follow lockout / tagout procedures SAFETY IGNITION MODULE TROUBLES HOOTING SYMPTOM – NO SPARK BETWEEN PILOT HEAD AND EL ECTRODE 1. Check for loose or greasy/dirty connections at all terminals (including electrode wire) 2.
- 13 - Disconnect the electrical power and follow lockout / tagout procedures SOLENOID VALVE TROUBLESHOOTI NG SYMPTOM – NO GAS FLOW TO BURNER 1. Check terminals for loose or greasy/dirty connections 2. Check gas pressure – check for orifice obstructio ns.
- 14 - PILOT The RRG Series Griddles utilize a solenoid valve with a brass pilot valve to control gas flow to pilot burners. One to three pilot flames can be fed by one valve – one leg of which may be branched. PILOT TROUBLESHOOTING SYMPTOM – PILOT WILL NOT LIGHT 1.
- 15 - HELPFUL HINT – If the unit is attached to a flexible gas line, you can extend the bullet feet out t o their fullest extension to raise the griddle and allow yourself more clearance while reaching under the unit. Remember to relevel the unit if you chose to do this.
- 16 - 2. Reach through the back of the unit. Squeeze the burner retaining clip and slide off burner retaining pin. 3. Lift the burner up so the retaining pin clears the corresponding hole in th e chassis, then pull the burner out through the back of the unit.
- 17 - GAS REGULATOR REGULATOR INSTALLED IN A HORI ZONTAL, UPRIGHT POSITION The RRG series units must have an exterior machine gas regulator installed. The units are shipped with a regulator that has a vent limiter. These regulators must be installed as close as possible to the unit in a horizontal, upright position for optimal performance.
- 18 - 12. Turn power switch and gas supply back on. All gas joints disturbed during ser vicing must be checked for leaks. Check with a soap and w ater soluti on. Do not use an open flame. PRESSURE TAP AT #1 BURNER SEQUENCE OF OPERATION Operation is the same for all size griddles.
- 19 - WIRING DIAGRAMS WIRING DIAGRAM – 24-INCH GRIDDLE.
- 20 - WIRING DIAGRAM – 36-INCH GRIDDLE.
- 21 - WIRING DIAGRAM – 48-INCH GRIDDLE.
- 22 - WIRING DIAGRAM – 60-INCH GRIDDLE.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Vulcan-Hart ML-135340-00036 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Vulcan-Hart ML-135340-00036 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Vulcan-Hart ML-135340-00036, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Vulcan-Hart ML-135340-00036 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Vulcan-Hart ML-135340-00036, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Vulcan-Hart ML-135340-00036.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Vulcan-Hart ML-135340-00036. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Vulcan-Hart ML-135340-00036 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.