GS, GL & GT SERIES FULL Y STEAM JACKETED GAS KETTLES MODEL GS25E ML-52633 GS30E ML-52634 GL40E ML-52635 GS60E ML-52660 GL80E ML-52637 GT100E ML-52638 GT125E ML-52639 GT150E ML-52640 VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL.
– 2 – IMPORT ANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED.
– 3 – T ABLE OF CONTENTS GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
– 4 – Installation, Operation and Care of GS, GL & GT SERIES FULL Y STEAM JACKETED GAS KETTLES KEEP THESE INSTRUCTIONS FOR FUTURE USE GENERAL Your Vulcan steam jacketed kettle is produced with quality workmanship and material. Proper installation, usage and maintenance will result in many years of satisfactory performance.
– 5 – INSTALLATION CODES AND STANDARDS In the United States, Vulcan kettles must be installed in accordance with state and local codes, with the National Fuel Gas Code, (ANSI-Z223.1, latest edition) available from the American Gas Association, 1515 Wilson Boulevard, Arlington, VA 22209, with the National Electrical Code (ANSI/NFPA No.
– 6 – FAUCET BRACKET A bracket is provided for mounting a faucet on the kettle; this would allow the addition of water to the kettle for the convenience of the food preparer. A faucet is available as an accessory. NOTE: Do not use tap water from faucet to fill kettle jacket.
– 7 – OPERA TION WARNING : THE KETTLE AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE KETTLE. Before operating, check the jacket water level by looking at the sight glass at the rear of the kettle with both upper and lower valves open.
– 8 – CONTROLS — KETTLES WITH ELECTRONIC IGNITION (Prior Construction, Fig. 2) Thermostat — Controls heat in the kettle. High dial settings are for cooking; low settings are for holding. On – Off Switch — Located on the upper right-hand corner of the control panel.
– 9 – Fig. 4 Low Water Cutoff — Pilot and Main Burner won't operate if water level in jacket is low. Pressure Relief Valve — Protect the kettle against excessive pressure should the thermo- Pressure Limit Switch stat malfunction.
– 10 – TURNING ON A KETTLE EQUIPPED WITH ELECTRONIC IGNITION (Applies to Fig. 1 or Fig. 2) Before lighting the pilot, both the burner and pilot must have been off at least 5 minutes. 1. Remove the control panel cover screw. 2. Remove the control box cover (lift, pull out at bottom, lower).
– 11 – CLEANING After each use, clean and flush the kettle liner immediately, especially if the product cooked contained salt, vinegar or acid in any concentration. Do not use chlorine based cleaning products. Do not use metalic scouring pads or brushes.
– 12 – MAINTENANCE WARNING : THE KETTLE AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE KETTLE. WARNING : DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURE. PRESSURE RELIEF VALVE Open the pressure relief valve at least once a day to avoid lime build-up.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Vulcan-Hart GS30E ML-52634 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Vulcan-Hart GS30E ML-52634 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Vulcan-Hart GS30E ML-52634, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Vulcan-Hart GS30E ML-52634 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Vulcan-Hart GS30E ML-52634, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Vulcan-Hart GS30E ML-52634.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Vulcan-Hart GS30E ML-52634. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Vulcan-Hart GS30E ML-52634 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.