Manuel d'utilisation / d'entretien du produit 855 du fabricant Viking
Aller à la page of 16
TECHNICAL SER VICE MANUAL VIKING PUMP , INC. • A Unit of IDEX Corporation • Cedar Falls, IA 50613 USA SECTION TSM P AGE ISSUE Introduction ................................................................... 1 Special Information ..................
SECTION TSM 685.2 ISSUE C P AGE 2 OF 16 BEFORE opening any liquid chamber (pumping chamber , reservoir, relief valve adjusting cap fitting, etc.) be sure that : ● Any pressure in the chamber has been completely vented through the suction or discharge lines or other appropriate openings or connections.
SECTION TSM 685.2 ISSUE C P AGE 3 OF 16 FIGURE 3 RELIEF V AL VE POSITION SPECIAL INFORMA TION ROT A TION : Viking Mag Drive® pumps are designed to run in either direction.
GAUGE PORT BOSS STORAGE: If the pump and coupling are to be stored, drain the pump and pour non-detergent SAE 30-weight oil into the pump port. Apply grease to the pump or the coupling shaft extension, if present or accessible. Viking suggests rotating the pump shaft every 30 days to circulate the oil in the pump.
SECTION TSM 685.2 ISSUE C P AGE 5 OF 16 EXPLODED VIEW – SIZES AS, AK, AL, KE & KKE MAG-DRIVE PUMPS FIGURE 6 ITEM NAME OF P ART ITEM NAME OF P ART ITEM NAME OF P ART 1 Locknut 37 Idler 53 Locatin.
SECTION TSM 685.2 ISSUE C P AGE 6 OF 16 MAGNETIC COUPLING OPTIONS Pump Size Magnetic Coupling Sizes AS B, C AK B, C AL B, C KE C KKE C COUPLING TORQUE AND SIZE OPTIONS T ABLE 3 TORQUE RA TINGS AND DRI.
SECTION TSM 685.2 ISSUE C P AGE 7 OF 16 6. Remove the idler and bushing assembly . If the idler bushing needs to be replaced, see “ INST ALLA TION OF BUSHINGS” on page 10. If further disassembly is required, the pump must be separated from coupling.
SECTION TSM 685.2 ISSUE C P AGE 8 OF 16 Buttonhead Screws Locknut Inner Magnet Set Collar Canister Bushing Canister O-ring Button Head Screws Canister and Casing Drain Holes DISASSEMBL Y OF COUPLING FIGURE 9 PUMP , INNER MAGNET AND CANISTER ASSEMBL Y Series MD2-B and MD2-C, All Sizes 1.
SECTION TSM 685.2 ISSUE C P AGE 9 OF 16 DISASSEMBL Y / ASSEMBL Y OF BEARING CARRIER DISASSEMBL Y The bearing carrier for an MD2 B coupling features two sealed ball bearings along with the outer magnet assembly . If further disassembly of this unit is required, reference Figure 7 on page 6 and Figure 13 then proceed as follows: 1.
SECTION TSM 685.2 ISSUE C P AGE 10 OF 16 INST ALLA TION OF BUSHINGS CARBON GRAPHITE The canister bushing (see Figure 9 on page 8) requires a special fixture for proper assembly so the bushing is only sold as part of the canister assembly .
SECTION TSM 685.2 ISSUE C P AGE 11 OF 16 Do not attempt to reuse a PTFE (derivative) encapsulated O-ring if it has been removed. Immerse a new O-ring in boiling water for a few minutes. Remove it from the water and stretch out the O-ring so it will fit onto the casing hub without forcing it over a sharp edge.
SECTION TSM 685.2 ISSUE C P AGE 12 OF 16 Series MD2-B and MD2-C, All Sizes DANGER ! Follow these directions exactly to avoid injury to self or damage to the pumping unit. Be care- ful to keep the inner and outer magnets at least (1) foot apart until step 4.
SECTION TSM 685.2 ISSUE C P AGE 13 OF 16 ADJUSTING END CLEARANCE T able 7-A provides standard operating end clearance for this pump. Use either of the following procedures to properly adjust the end clearance when replacing shims or reassembling the pump.
SECTION TSM 685.2 ISSUE C P AGE 14 OF 16 FIGURE 22 V AL VE – AS, AK, AL, KE AND KKE SIZES V AL VE - LIST OF P ARTS 1. V alve Cap 6. V alve Body 2. Adjusting Screw 7. V alve Spring 3. Lock Nut 8. Poppet 4. Spring Guide 9. Cap Gasket 5. Bonnet DISASSEMBL Y – RELIEF V AL VE Mark the valve and head before disassembly to insure proper reassembly .
SECTION TSM 685.2 ISSUE C P AGE 15 OF 16 TROUBLESHOOTING Some of the following may help pinpoint the problem: Pump does not pump: • Pump has lost its prime from air leak or low level in tank. • Suction lift is too high. • Pump is rotating in the wrong direction.
TECHNICAL SER VICE MANUAL VIKING PUMP , INC. • A Unit of IDEX Corporation • Cedar Falls, IA 50613 USA © 5/2007 Viking Pump Inc. All rights reserved SECTION TSM P AGE ISSUE W ARRANTY Viking warran.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Viking 855 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Viking 855 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Viking 855, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Viking 855 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Viking 855, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Viking 855.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Viking 855. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Viking 855 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.