CAC 1 Installation, Operation and Maintenance Instructions TABLE OF CONTENTS IMPORTANT SAFETY INFORMATION ................................................................................................... .............................................
2 CAC FIGURE 1 - MINIMUM CLEARANCES TO COMBUSTIBLES FIGURE 2 - MINIMUM CLEARANCES TO COMBUSTIBLES When selecting a location for the heater, be sure attention is given to the following considerations: 1.
CAC 3 FIGURE 3 - MINIMUM CLEARANCES TO COMBUSTIBLES FIGURE 4 - MINIMUM CLEARANCES TO COMBUSTIBLES SIDE SECTION VIEW PLAN SECTION VIEW.
4 CAC FIGURE 5 - FLOOR PROTECTION FLOOR PROTECTION This heater has been designed to prevent excessive temperatures on the floor beneath the heater. It is important, however, tha t a combustible floor be protected by a 3/8 inch minimum thick noncombustible inorganic millboard having a thermal conductivity of K=0.
CAC 5 There are five allowable ways that a chimney connector can be connected to a masonry chimney by passing through a combustible wall. NFPA Standard 211 allows the following wall pass-through systems. Use a minimum 3-1/2" thick brick masonry wall framed into the combustible wall.
6 CAC MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN. CHIMNEY LENGTH FLUSH WITH INSIDE OF FLUE NONSOLUBLE REFACTORY CEMENT MASONRY CHIMNEY CONSTRUCTED TO NFPA 211 CHIMNEY CONNECTOR TO HEATER MINIMUM CLEARANCE 9 IN.
CAC 7 SHEET STEEL SUPPORTS CHIMNEY SECTION CHIMNEY CONNECTOR AIR SPACE 2 IN. TWO VENTILATED AIR CHANNELS EACH 1 INCH. CONSTRUCTED OF SHEET STEEL. PART C FIGURE 5 PART D FIGURE 5 MINIMUM CLEARANCE 2 IN. ALL AROUND CHIMNEY THIMBLE 1 IN. AIR SPACE TO CHIMNEY LENGTH MASONRY CHIMNEY CONSTRUCTED TO NFPA 211 SHEET STEEL SUPPORTS (24 GAUGE MIN.
8 CAC FIGURE 8 - CONNECTING HEATER’S CHIMNEY CONNECTOR TO MASONRY CHIMNEY WHEN CHIMNEY CON- NECTOR DOES NOT HAVE TO PASS THROUGH A COMBUSTIBLE WALL CAUTION: IF THIS HEATER IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW THE INSTALLATION DIRECTIONS.
CAC 9 Two common types of clearance reductions systems use sheet metal with a thickness of 28 gauge (galvanized steel, aluminum, copper) or a 3-1/2 inch (4 inch thick nominal) thick masonry wall. Either of these materials must be spaced out 1 inch from th e combustible surfaces.
10 CAC FIGURE 9 - HEATER OPERATION INFORMATION HEATER OPERATION IMPORTANT: DO NOT USE THE HEATER UNTIL A PROFESSIONAL INSPECTION HAS BEEN MADE OF THE ENTIRE INSTALLATION BY YOUR LOCAL FIRE DEPARTMENT, FIRE MARSHAL OR BUILDING CODE INSPEC- TOR.
CAC 11 FIGURE 10 - OPENING AND CLOSING FUEL FEED DOOR 5. When the wood is burning briskly, add additional kindling as required to establish a good kindling fire. 6. When the kindling fire has been established and is burning briskly, cover it with a thin layer of coal.
12 CAC 8. DO NOT OVERFIRE THE HEATER. If any part of the heater or chimney connector becomes red hot, the heater is being overfired. Immediately turn the heater’s thermostat to “LO” and keep the fuel feed door and ash removal door closed until the heater cools.
CAC 13 Ashes should never be placed in wooden or plastic containers, or in paper or plastic bags, no matter how long the fire has been out. Coals have been known to stay hot for several days when embedded in ashes.
14 CAC FIGURE 11 - CHIMNEY HEIGHT REQUIREMENTS WHAT TO DO IF THE HEATER SMOKES OR BURNS POORLY OR EXCESSIVE CREOSOTE ACCUMULATES IN THE CHIMNEY 1. Open a window slightly to see if the conditions improve.
CAC 15 QUICK REFERENCE TO THE MOST COMMON SOLUTIONS FOR THE MOST COMMON HEATER OPERATIONAL PROBLEMS 1. Symptom: Fire rate does not increase with thermostat open, smoke spilling from feed door when tending fire or backpuffing. Check for: a. Chimney connector pushed too far into a masonry chimney thimble restricting draft.
16 CAC 25 . Do assemble the chimney connector so that moisture that accumulates within the chimney will flow back toward the heater. 26. Do remove the ashes from the heater regularly. 27. Do set the thermostat on “HI” and allow the heater to burn for approximately 15 minutes after fresh coal is added before reducing the thermostat setting.
CAC 17 FIGURE 12 ILLUSTRATION OF REPAIR PARTS. SEE LEDGER ON NEXT PAGE FOR PART NAMES AND PART NUMBERS..
18 CAC SEE FIGURE 12 FOR ILLUSTRATION OF PARTS CUSTOMER NOTE: IN ADDI- TION TO THE REPAIR PARTS, KITS INCLUDE ANY RE- PLACEMENT FASTENERS WHICH WILL MOST LIKELY BE NEEDED TO INSTALL THE REPAIR PART. N/S = Not Shown K EY QTY. CA C NO . PART NAME Per Unit PART NO.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté United States Stove DR6 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du United States Stove DR6 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation United States Stove DR6, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le United States Stove DR6 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le United States Stove DR6, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du United States Stove DR6.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le United States Stove DR6. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei United States Stove DR6 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.