USSC 1 CAUTION: READ ALL INSTRUCTIONS CARE- FULLY BEFORE STARTING THE INSTALLATION OR OPERATING THE HEATER IMPROPER INSTALLATION MAY VOID YOUR WARRANTY DO NOT USE THIS HEATER IN A MOBILE HOME OR TRAILER 851523 C R US UNITED STATES STOVE COMPANY 227 Industrial Park Road P.
2 USSC SAFETY PRECAUTIONS PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW HEATING APPLIANCE. FAIL- URE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. THIS HEATING APPLIANCE SHOULD BE INSTALLED ONLY BY AN EXPERIENCED COAL HEATER INSTALLER.
USSC 3 Before Assembly, inspect the heater thoroghly for missing parts or shipping damage. If any damage or missing parts are detected, report it to your heater dealer.
4 USSC FIGURE 1 - MASONRY CHIMNEY REQUIREMENTS FLUE MINIMUM 1/2" AIR SPACE FOUNDATION CHIMNEY WALL 4" NOMINAL 5/8" FIRECLAY OR STAINLESS STEAL FLUE LINER If the heater is to be connected to a masonry chimney, the heater should not be installed until it is determined that the chimney is safe for use.
USSC 5 FIGURE 4- CHIMNEY HEIGHT REQUIREMENTS A Chimney must be the required height above the roof or other obstruction for safety and for proper draft op- eration.
6 USSC Figure 5 shows how to connect the chimney connector of a heater to a masonry chimney through a combustible wall. There are five allowable ways that a chimney connector can be connected to a masonry chimney by passing through a combustible wall.
USSC 7 CHIMNEY FLUE MINIMUM CHIMNEY CLEARANCE TO BRICK AND COMBUSTIBLES IS 2 IN. MINIMUM CLEARANCES 12 IN. OF BRICK ALL AROUND CHINEY CONNECTOR TO HEATER FIRE CLAY LINER (5/8" MIN. WALL THICKNESS) MIN. 3-1/2" THICK BRICK MASONRY WALL MASONRY CHIMNEY CONSTRUCTED TO NFPA 211 MINIMUM 12 IN.
8 USSC PART E - (Figure 5) In addition to the methods shown by A, B, C, and D of Figure 5, a listed factory-built wall pass-through system may be purchased and installed according to the instructions packaged with it to provide a safe method of passing chimney connector through a combustible wall for a connection to a masonry chimney.
USSC 9 METAL PREFABRICATED CHIMNEY REQUIREMENTS Any metal prefabricated chimney that this heater is connected to must be a Listed High Temperature Type 103-HT Factory- Built Residential Type and Building Heating Appliance Chimney. Its interior size should be no smaller than 6 inches in diameter or no larger than 8 inches in diameter.
10 USSC COMBUSTIBLE CEILING JOIST SPECIFIED CLEARANCE INSULATION SHEILD LISTED CHIMNEY TO HEATER CEILING SUPPORT CHIMNEY CONNECTOR ROOF FLASHING STORM COLLAR CHIMNEY CAP (WITH SPARK ARRESTER IF DESIRED OR WHERE REQUIRED BY LAW.
USSC 11 SECTION LISTED CHIMNEY PIPE TO HEATER TRIM COLLAR ON INSIDE WALL CHIMNEY CONNECTOR LISTED CHIMNEY INSULATED "T" WALL SUPPORT WALL SPACER ON OUTSIDE WALL 2" CLEARANCE (BETWEEN WALL AND CHIMNEY) COMBUSTIBLE OUTSIDE WALL CHIMNEY CAP (WITH SPARK ARRESTER IF DESIRED OR WHERE REQUIRED BY LAW.
12 USSC HEATER INSTALLATION CAUTION: FOR YOUR SAFETY, THE INSTALLATION OF THIS HEATER MUST COMPLY WITH LOCAL CODES AND REGULATIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT INSPECTION TO ASSURE PROPER COMPLIANCE WITH LOCAL CODES AND REGULATIONS.
USSC 13 FIGURE 9 - PLAN VIEWS SHOWING FLOOR PROTECTOR'S MINIMUM SIZE (DIMENSIONS IN INCHES) Masonry, or other non-combustible products, attached directly to a combustible surface without an air s.
14 USSC 6. Place the crimped end of the first chimney pipe or elbow into the heater's flue collar and mark it through each of the holes in the heater's flue collar. 7. Remove the pipe or elbow from the flue collar and drill 1/8 - inch diameter holes at the points marked.
USSC 15 OPERATING INSTRUCTIONS Burning Coal in your 4027/ASA7 Your Wondercoal is capable of burning both bituminous and Anthracite coal. Anthracite is the best coal fuel because its long even burn time, high heat output, and cleanliness make it a good choice for the home.
16 USSC CAUTION! ASHES SHOULD NEVER BE ALLOWED TO ACCUMULATE ABOVE THE TOP OF THE ASH PAN. ASHES IN CONTACT WITH THE BOTTOM OF THE GRATES ACT AS AN INSULATOR, INTENSIFYING THE HEAT ON THE GRATES AND COULD CAUSE THEIR WARPAGE. WITH AN EXCESSIVE ASH BUILDUP, PRIMARY COMBUSTION AIR IS RESTRICTED, THUS THE UNIT’S OUTPUT COULD BE REDUCED.
USSC 17 OPERATING INSTRUCTIONS continued... Before opening the loading door, open the pipe damper and the ash door first. Whenever a loading door is opened, it always should be cracked slightly to allow oxygen to enter and burn any combus- tion gases that are present before fully opening.
18 USSC 1 2 3 4 56 7 89 10 12 11 13 16 19 14 15 18 20 17 15 16 26 25 24 20 21 22 23 4027 & ASA7 Repair Parts.
USSC 19 MODEL 4027 & ASA7 - PARTS LIST KEY PART NO. DESCRITION QTY. 1 40422 Cast Iron Legs 4 • 83507 3/8-16 x 1-1/4 Bolt 4 2 25096 Flue Collar 1 • 83431 Weld Tab 3 • 83045A Washer 3/8 i.
20 USSC THIS MANUAL WILL HELP YOU OBTAIN EFFICIENT, DEPEND- ABLE SERVICE FROM YOUR HOTBLAST FURNACE, AND EN- ABLE YOU TO ORDER REPAIR PARTS CORRECTLY. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFER- ENCE. WHEN WRITING, ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté United States Stove ASA7 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du United States Stove ASA7 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation United States Stove ASA7, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le United States Stove ASA7 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le United States Stove ASA7, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du United States Stove ASA7.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le United States Stove ASA7. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei United States Stove ASA7 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.