Manuel d'utilisation / d'entretien du produit 1600M du fabricant United States Stove
Aller à la page of 20
1 Installation/Operator's Manual #851547A MODEL: 1600M MODEL: 1600M MODEL: 1600M MODEL: 1600M MODEL: 1600M WOOD and COAL FURNACE SAFETY NOTICE: IF THIS FURNACE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW THE INSTALLATION DIRECTIONS.
2 INTRODUCTION Thank you for your purchase of a U.S. Stove Wood and Coal burning furnace. Your decision to buy our Clayton Furnace was undoubtedly reached after much careful thought and considera- tion. We are very proud you chose the U.S. Stove furnace and trust you will receive the comfort and economy that others realize when heating with a U.
3 NOTE: Type of chimney: Class A All-Fuel UL 103HT 1. The furnace should be the only heating appliance using a chimney flue. One furnace per flue. 2. A masonry chimney should have a tile or stainless steel liner. 3. The masonry chimney should not have any missing mortar or loose bricks.
4 maintains clearances, keeps condensation and creosote within the pipe, and is capable of withstanding a two to three thousand degree chimney fire. 1. The connector pipe should slant down toward the furnace a minimum of 1/4" to the foot. At no time should the pipe turn downward toward the chimney or run horizontal.
5 COMBUSTION AIR All fires need air (specifically oxygen) to burn. Furnaces, fire- places, and wood-burning furnaces need enough oxygen for complete combustion of their fuels.
6 Your furnace is shipped from the factory in four (2) packages. 1) the furnace, 2) the blower. The draft kit and parts box containing all parts necessary, and the fan thermodisc kit is boxed and packed in the firebox or ash pan.
7 SMOKE CHAMBER (If re-assembly is necessary): 1. Place #1 firebrick in the back of smoke chamber. 2. Slide baffle plate into smoke chamber, flat side down. 3. Place remaining firebrick in smoke chamber as numbered below. (In placing the firebrick in the smoke chamber, lift the left side of firebrick first and drop into place.
8 DISTRIBUTION BLOWER INSTALLATION Distribution blower slides onto rear of furnace. Engage blower flange with channels and press down. SHAKER GRATE HANDLE INSTALLATION 1. Attach angle with two 1/4" x 3/4" hex bolts and two 1/4" lock nuts.
9 ALL WIRING MUST BE DONE BY A QUALIFIED ELECTRICIAN Predrilled holes are provided on the back of the furnace for mounting the electrical box. ELECTRICAL INSTALLATION.
10 ALL WIRING MUST BE DONE BY A QUALIFIED ELECTRICIAN.
11 5. Close the spin draft cap on ash door. 6. The motorized natural draft cycles on demand from the U.S. Stove wall thermostat. Setting the thermostat four degrees higher that your existing thermostat is recom- mended. During operation, the motorized natural draft remains open until the thermostat temperature setting is reached.
12 OPERATING NOTES Do not over draft the furnace! It is designed to operate at .06 inches of water column and must be set with a draft gauge to maintain a steady draft. (Barometric Damper recommended.) Do not allow ashes to build up higher than 2" above grates.
13 TROUBLE SHOOTING AND PROBLEM SOLVING 1. Problem: Smoke puffs from furnace Solution: A . Check chimney draft. Check for blocked chimney or flue pipe. Use mirror to check chimney clearance. B . Check ash pit — if it is too full, empty. C . Make sure furnace room is not too airtight.
14 ITEM DECRIPTION PART # 1 5 Baffle Rod 86603 1 6 Top Insulation C98871 1 7 Front Filler 23817 1 8 Draft Cover 23818 1 9 Top Flue Ring 22761 2 0 Draft Cap (2) 23859 2 1 3/8" x 2-1/2" Bolt (.
15 PARTS LIST 29 35 33 27 34 26 30 40 37 39 38 ITEM DESCRIPTION PART# 2 6 Top Safety Latch 23786 2 7 Feed Door 69091 2 8 Ash Door 68880 2 9 Door Latch Handle 24179(2) 3 0 Ash Door Latch 23823 3 1 1/2&.
16 PARTS LIST MODELS 1600M Fan Thermodisc Kit #69455 ITEM DESCRIPTION PART# 1 3-Speed Switch 80361 2 Plastic Knob C9267M 3 Low Speed Thermodisc 80388 2 1 5 MODEL 1600M - Blower Motor Kit #69160 (1400C.
17 ITEM DESCRIPTION PART# 1 Draft Blower 80422 2 Power Supply Cord C40899 3 FAD Bracket 69192 4 10-24 Kep Nut (3ea.) 83244 5 1/4-20 x 1" Bolt (2ea) 83379 6 1/4-20 Lock Nut 83261 FORCED AIR DRAFT .
18 INSTALLATION OF OPTIONAL EQUIPMENT INSTALLING DOMESTIC HOT WATER COIL 1. Remove access panel at rear of enclosure. 2. With a utility knife cut out the section of fiberglass insulation directly behind the access panel. 3. Remove cover plate from rear of firebox.
19 INSTALLING OPTIONAL BACK DRAFT DAMPER The back draft damper may be installed in either a vertical or horizontal section of the hot air duct. It should be positioned as close to the plenum opening of the furnace as practical. Press female end of the back draft damper over Clayton Furnace collar or male end of the duct pipe.
20 HO W TO ORDER REP AIR P AR TS THIS MANUAL WILL HELP YOU OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM THE HEATER, AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE. WHEN WRITING, ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE BACK OF THE HEATER.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté United States Stove 1600M c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du United States Stove 1600M - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation United States Stove 1600M, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le United States Stove 1600M va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le United States Stove 1600M, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du United States Stove 1600M.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le United States Stove 1600M. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei United States Stove 1600M ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.