INST ALLA TION MANUAL - 50 HZ CAUTION: READ ALL SAFETY GUIDES BEFORE YOU BEGIN TO INST ALL YOUR UNIT . SA VE THIS MANUAL CHAMPION ® SERIES SINGLE P ACKAGE AIR CONDITIONERS ELECTRIC/ELECTRIC, AIR-COOLED MODELS: D1EB036, 048 DIRECT DRIVE D1EB060 BEL T DRIVE (WORLD 50 HZ) 173858-YIM-A-0306 CONTENTS GENERAL .
173858-YIM-A-0306 2 Unitary Products Group T ABLE OF CONTENTS GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 REFERENCE . . . . .
173858-YIM-A-0306 Unitary Products Group 3 GENERAL Model D1EB units are factory assembled cooling only air con- ditioners designed for outdoor installation on a rooftop or a slab. The units are completely assembled on rigid, but easily removable base rails.
173858-YIM-A-0306 4 Unitary Products Group should meet local codes an d unit weight. Do not tie the slab to the build ing foundation. 4. For roof top installation, be sure the structure will support the weight of the unit plus a ny field installed components.
173858-YIM-A-0306 Unitary Products Group 5 Duct work should be designed and size d according to the methods of the Air Condition ing Contractors of America (ACCA), as set forth in their Manual D. A closed return duct system sha ll be used. This shall not pre- clude use of econo mizers or ve ntilation air intake.
173858-YIM-A-0306 6 Unitary Products Group T ABLE 3: PHYSICAL DA T A COMPONENT MODELS DEB036 DEB048 DEB060 NOMINAL TONNAGE 3.0 4.0 5.0 COOLING PERFORMANCE RA TING T1 T2 T2 T1 T2 T3 T 1 T2 T3 Indoor DB.
173858-YIM-A-0306 Unitary Products Group 7 POWER AND CONTROL WIRING Field wiring to the unit must conform to provision s of the cur- rent N.E.C. ANSI/NFP A No. 70 or C.E.C. and/or local ordi- nances. The unit must be electric ally grounded in accordance with local codes or , i n their absence, with th e N.
173858-YIM-A-0306 8 Unitary Products Group CHECKING SUPPLY AIR CFM T o check the supply air CF M after the initial balancing has been completed: 1. Remove the two ¼ inch dot plugs in the duct panel. 2. Insert at least 8 i nches of ¼ inch tubing into each of these holes for sufficient penetration into the airflow on both sides of the indoor coil.
173858-YIM-A-0306 Unitary Products Group 9 T ABLE 5: ADDITIONA L ST A TIC RESIST ANCE Size (T ons) Model Airflow m 3 /s (cfm) Wet Indoor Coil Pa (in.wc) Economizer 1 Pa (in.wc) Filter / Frame Kit Pa (in.wc) 036 (3.0) DEB 0.42 (900) 0.47 (1000) 0.52 (1 100) 0.
173858-YIM-A-0306 10 Unitary Products Group T ABLE 6: D1EB036 SUPERHEAT CHARGING (IMPERIAL) OUT DOOR TEMPERA TURE (°F) SUPERHEAT AT COMPRESSOR SUCTION (°F) AIRFLOW = 1,300 CFM INDOOR WB T E MPERA TURE (°F) 55 57 59 61 63 65 67 69 71 73 75 65 21.1 21.
173858-YIM-A-0306 Unitary Products Group 11 T ABLE 8: D1EB048 SUPERHEAT CHARGING (IMPERIAL) OUTDOO R TEMPERA TURE (°F) SUPERHEAT AT COMPRESSOR SUCTION (°F) AIRFLOW = 1,800 CFM INDOOR WB T EMPERATURE (°F) 55 57 59 61 63 65 67 69 71 73 75 65 19.9 21.
173858-YIM-A-0306 12 Unitary Products Group T ABLE 10: D1EB060 SUPERHEAT CHARGING (IMPERIAL) OUTDOOR TEMPERA TURE (°F) SUPERHEAT AT COMPRESSOR SUCTION (°F) AIRFLOW = 2,000 CFM INDOOR WB T EMPERATURE (°F) 55 57 59 61 63 65 67 69 71 73 75 65 21.9 23.
173858-YIM-A-0306 Unitary Products Group 13 FIGURE 5 - UNIT DIMENSIONS +,*+92/ 7$*(&211 ´',$.12&.287 +,*+92/ 7$*(&211 ´',$.12&.
173858-YIM-A-0306 14 Unitary Products Group SEQUENCE OF OPERA TION COOLING The following sequence s of operation are based on using a standard single-stage cooling thermostat.
173858-YIM-A-0306 Unitary Products Group 15 FIGURE 3 - TYPICAL WIRING DIAGRA M 3 & 4 TON (380/415-3-50 POWER SUPPLY).
173858-YIM-A-0306 16 Unitary Products Group FIGURE 4 - TYPICAL WIRING DIAGRAM 5 TON (380/415-3-50 POWER SUPPLY).
173858-YIM-A-0306 Unitary Products Group 17 FIGURE 5 - TYPICAL WIRING DIAGRAM LEGEN D FIGURE 6 - TYPICAL WIRING DIAGRAM NOTE S &% &2035 ) )= +3 . . /3 0 0 0 5& 5& 63 63 63 63 7 &,5&8,7%5($.
173858-YIM-A-0306 18 Unitary Products Group.
173858-YIM-A-0306 Unitary Products Group 19.
Subject to change without notice. Print ed in U.S.A. 173858-YIM-A-0306 Copyright © 2006 by Unitary Products Gro up. All rights reserved. Supersedes: Nothing Unitary 5005 Norman Product s Y ork OK Gro.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Unitary products group D1EB036 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Unitary products group D1EB036 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Unitary products group D1EB036, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Unitary products group D1EB036 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Unitary products group D1EB036, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Unitary products group D1EB036.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Unitary products group D1EB036. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Unitary products group D1EB036 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.