UH-040XR Operating Guide.
➤ Do not operate the transmitter of any radio equipment unless all the Radio Frequency (RF) connectors are secured and any open connectors are properly terminated. ➤ Do not operate the transmitter of any radio equipment near electrical blasting caps or in an explosive atmosphere.
Introduction Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 T echnical Support & Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Included in your UH-040XR Package . . . . . . . . .
The UH-040XR is a portable two-way UHF-CB radio. It is compact, rugged and fits easily in your hand. This hand held UHF radio will give you consistent, outstanding performance in virtually all conditions and situations.
TECHNICAL SUPPORT AND SERVICE Should you find it desirable or necessary to service your UH-040XR , we suggest you contact the Uniden dealer where you purchase your radio.
INCLUDED IN YOUR UH-040XR P ACKAGE 3 3 Note: If any of these items are missing from the box, contact your Uniden Dealer . Wrist Strap Belt Clip Operating Guide Product Registration Card and other prin.
BA TTERY INST ALLA TION Y our UH040XR radio uses 3 AA ALKALINE batteries for power . Please refer to page 14 should you wish to use rechargeable batteries. T o install the batteries: 1. Make sure your radio is off. 2. Release the battery cover clip, then remove the battery cover .
LOW BA TTERY ALERT The LCD on your radio shows a battery meter in the lower right corner . icon indicates a fully powered unit. As the batteries lose power , will flash. When the batteries in the unit are low , the unit will go into a Battery Low/Sleep Mode.
➤ When you press any key (except PTT), a short tone sounds. ➤ See the Controls and Indicators page at the back of this operating guide for button and key operations. POWER ON/OFF T o turn the unit ON , rotate the [ON/OFF VOL] clockwise until a “click” is heard.
SELECTING CHANNEL Press [ ▲ ] or [ ▼ ] to select the desired channel. Note: If you press and hold the [ ▲ ] or [ ▼ ], channel numbers will scroll rapidly . TO TRANSMIT AND RECEIVE The UH-040XR uses the 40 UHF-CB Channels. For your reference a list of the available channels and corresponding frequencies is printed at the end of this manual.
TO OPERA TE IN DUPLEX MODE Eg. CH01 is being used in your area for repeater use. Press [DUP] momentarily . The DUP icon appears. Press [DUP] again to deactivate the duplex operation.
Example. CH40 becomes active If the received signal cease, the unit will wait for at least 3 seconds for the signal to return, otherwise scanning resumes. T o skip the active channel, press [MEM] momentarily . Scanning resumes. T o deactivate SCAN, press the [SCAN] or [PTT] .
PRIORITY CHANNEL The Priority Channel feature allows user to monitor one of 40 channels in the UH-040XR , monitoring it every 1.5secs during Group Scanning . Choosing a Priority Channel The starting channel, when Group Scanning is initiated, is always the Priority Channel .
DROP-OUT DELA Y While scanning, the UH-040XR stops at a busy channel and receives a transmission. When the received signal is over , the unit will wait for 3 seconds for the return of the signal, otherwise, the radio resumes scanning. KEYP AD CONFIRMANTION TONE Assures the user that the keypad has been properly pressed by emitting a beep tone.
BACK LIGHTING The Liquid Crystal Display (LCD) is backlit for easy viewing at night or in low light situations. The back lighting automatically switches ON every time a key (except PTT) is pressed. It turns OFF 5secs after the last key is pressed. KEYP AD LOCK T o prevent accidental entries, you can lock the keypad.
BA TTERY LEVEL DISPLA Y The icon in the bottom right hand corner of the screen indicates the UH-040XR current battery voltage level at all times. The battery level is displayed in 3 levels: LEVEL 3 Ba.
CHARGING BA TTERIES W arning Notice! Use only the AAD042S optional power adaptor if rechargeable batteries will be used in the UH040XR. •T urn the UH040XR [ ON/OFF VOL] knob off and connect the AC adaptor plug to the mic jack. • Battery charging times vary .
* Emergency calling for both simplex and duplex operation Please do not use this channel in non-emergency cases. # Back-up Emergency Channel Ch. Freq. Usage Ch. Freq. Usage 01 476.425 Simplex/Duplex 21 476.925 Simplex 02 476.450 Simplex/Duplex 22 476.
• Speaker Microphone (SM-050) • AC Adaptor (AAD-042S) • Headset Microphone (HM-050) General Channels T ransmit 40 (with Duplex Channel Support) Receive 40 Oper .
Receiver Receiver T ype Dual Conversion Super Heterodyne Phase Locked Loop System for Local Oscillator Frequency Range 476.425 to 477.4 MHz Sensitivity @ 0.22 µV 12 dB SINAD Squelch Sensitivity 0.19 µV (Threshold) Audio Frequency Response 500Hz, 5dB (ref: 1KHz, ± 3KHz Dev .
UNIDEN UH-040XR UHF CB RADIO Limited One Y ear Warranty Note: Please keep your sales docket as it provides evidence of warranty . Warrantor: Uniden Australia Pty Limited ACN 001 865 498 Uniden New Zea.
OS/GS MEM DUP SCAN 5 4 13 14 15 6 7 8 9 3 2 1 10 11 12 CONTROLS & INDICA TORS 19.
1. Speaker Jack 2. Microphone Jack 3. On/Off V olume 4. LCD Display 5. Up Button 6. Down Button 7. Microphone 8. Speaker 9. Scan Button 10. Open/Group Scan Button 11. Memory On/Off Button 12. Duplex On/Off Button 13. PTT (Push-to-talk) Button 14. Monitor Switch 15.
© 2000 Uniden Australia Pty Limited/Uniden New Zealand Limited UTZZ01876ZZ.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Uniden UH-040XR c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Uniden UH-040XR - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Uniden UH-040XR, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Uniden UH-040XR va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Uniden UH-040XR, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Uniden UH-040XR.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Uniden UH-040XR. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Uniden UH-040XR ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.