Manuel d'utilisation / d'entretien du produit TEG-S4000 du fabricant TRENDnet
Aller à la page of 28
TEG-S4000 4-Slot Modular Switch U s e r ’ s G u i d e.
Copyright Statement COPYRIGH T 2003 ALL RIG HT RESERVED. First Edition. Pr inted in T aiwan. All tradem ark s are the properties of their r espective owners. No portion of this docum ent m ay be reproduc ed, alter ed, adapt ed or translated without the prior written approval.
Chapter 1 Introduction The 4-Slot Modular Switch are multi-speed network devices combining Ethernet, Fast Ethernet and Gigabit Ethernet capabilities in a single comp act, rack-mountable cabinet.
Four Rubber feet User manual.
Device Description, Features and Capabilities 4-Slot Modular Switch Front and Rear Panels This section describes the f eatures on the front and rear panels of the 4-Slot Modular Switch unit. Figure 1-2. Fr ont Panel Figure 1-3. Rear Panel All LED status indicators are located on the FRONT panel of the switches.
Full Duplex/Col Red Full Duplex/Col indicators are illuminated when that port is in full duplex mode. The indicator is of f when that port is in half duplex mode . When a collision occurs on the network connected to a port, that Full Duplex/Col indicator blinks.
Filtering and forwarding rate of 14,880~148,800 packet s per second.
2 ports 100Base-FX Fiber Module Figure 1-6. 2 port 100Base-FX Module Fr ont V iew When installed into a 4-Slot Modular Switch, this Module provides a 100Mbps Fast Ethernet fiber port which can be used.
2 ports 100Base-FX Fiber Module Features Conforms to IEEE 802.3u Fast Ethernet standard Support for SC or ST fiber connectors (optional) Supports half and full duplex modes via DIP switches S tore-and-forward switch architecture for abnormal packet filtering 2 switching 100Mbps Fiber Ethernet port s Back-plane up to 2.
Por t 1 Por t 3 Por t 4 Por t 2 DIP Sw i t ch L o cati o n Full D uplex Half Dup lex 4 3 2 1 ON OF F Figure 1-9. Location and setting duplex mode The following T able1-3.
module. 1000Base-SX/LX Fiber Module Figure 1-10. 1000Base-SX/LX Fr ont V iew When installed into a 4-Slot Modular Switch, the 1000Base-SX/LX Module provides 1 Gigabit Ethernet ports which can connect the 4-Slot Modular Switch to a Gigabit Backbone Switch or Server with Gigabit NIC.
1x1000Base-T Ethernet Port 128 K Bytes p a cket bu f fer support Automatic address learning with 4K address entry storage S tandard auto-negotiation for speed, duplex mode and flow-con.
Chapter 2 Planning your Network Before you install your 4-Slot Modular Switch, you should review the guidelines for setting up Ethernet networks. Further , you should plan your network to take maximum advantage of it s switching capabilities.
1000BASE-SX /LX / TX Network Guideline 1000BASE-SX In Multi-mode, the fiber opt ic segment cannot exceed 220m (62.5/125 µ m) or 500m (50/125 µ m) in length. 1000BASE-LX In Multi-mode, the fiber opt ic segment cannot exceed 550m(62.5/125 µ m), 550m(50/125 µ m) in length.
Y ou can expand your 10Base-T or 100Base-TX or 1000Base-SX/LX/T networks beyond it s hub limit by adding a 4-Slot Modular Switch. 10Base-T Networks 10Base-T Networks are limited to four hubs between any two nodes. By adding your 4-Slot Modular Switch to a network, you can divide that network into segments with their own collision domains.
Figure 2-2. Expanding your 100Base-TX network (Class I) Collapsed Backbone Link T raditionally , bridges and routers have been used to link local area networks into one interconnected network. But these devices involve difficult management and long traffic delays.
Figure 2-3. 4-Slot Modular Switch 100/1000 Hub in a collapsed backbone link Fileserver Link 100Base Solution With a fileserver link, you can increase file server performance by increasing the Hub's bandwidth between one or more fileservers and the workgroups they serve.
Figure 2-4. Fileserver Link Connecting servers through 100Base-TX ports increases performance to the clients, even if the client s are on 10Base-T segment s.
Figure 2-5. Used as a Multiport Bridge Using your hub, you can also connect 10Base-T networks and 100Base-TX and 1000Base-SX/LX networks together for more flexibility in your network topology .
Chapter 3 Installation The Switch can be installed quickly and easily . However , for an inst allation with minimum impact on the existing network, please read this chapter carefully . Installing a 4-Slot Modular Swit ch involves three step s: 1. Choosing a location 2.
Rack Installation Y our switch comes with two rack mounting brackets. you can use these brackets to mount the switch on an EIA standard 19" rack. Att ach the brackets to the switch, using the screws provided.
make sure that: The 10Base-T twisted p air Ethernet cabling is Category 3 or above. The 100Base-TX Fast Ethernet cabling is tested Category 5. The 1000Base-T Gigabit Ethernet cabling is tested Category 5 enhanced. The 100Base-FX fiber cabling is 62.
from the rear of the Switch. Do not remove any other screws from the rear of the Switch. 3. Keep the blanking plate and screws in a safe place. If you remove the Module at any time, you must replace the blanking plate to prevent dust and debris from entering the Switch and to aid the circulation of cooling air .
a. Remove the protective plastic covers from the fiber connectors on the Module. b. Ensure that the Switch is powered up. c. Plug the SC connector on the fi ber cable into the fiber socket on the Module. d. Connect the other end of the fiber optic segment to an appropriate device fitted with a 1000Mbps adapter .
100V AC to 240V AC 50Hz to 60Hz Environment: Operating S torage T emperature 0 ℃ to 45 ℃ -40 ℃ to 70 ℃ Humidity 10% to 90% RH 10% to 90% RH Dimensions: 440mm x 225mm x 66mm EMI & Safety: F.
1000Mbps indicator for 1000T module Power on/off indicator.
Appendix B. Pin Assignments RJ-45 station port s can be attached to any device which use a standard network interface (e.g., a workst ation, server , bridge or router). RJ-45 daisy-chain ports can be cascaded to a station port on similar networking devices (e.
Schematics for both S traight-Throug h and C rossov er twis ted-pair cable are show n below . Straight-Through Crossover Switch Adapter Switch Hub 1 RD + 1 TD + 1 RD + 1 RD + 2 RD - 2 TD -.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté TRENDnet TEG-S4000 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du TRENDnet TEG-S4000 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation TRENDnet TEG-S4000, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le TRENDnet TEG-S4000 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le TRENDnet TEG-S4000, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du TRENDnet TEG-S4000.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le TRENDnet TEG-S4000. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei TRENDnet TEG-S4000 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.