DS Series Manual DATA SWITCH DS74 Serial Input - Output Module BayTech Manual Publication Revision May 2008.
DS74 Serial I/O Module 2 Copyright 2007 by Bay Technical Associates, Inc. BayTech, is a registered trademarks of Bay Technical Associates, Inc. Windows 2000®, Windows XP® are products and reg istered trademark of Microsoft Corporation. Tera Term is a product and registered trademark of Vector, I nc.
DS74 Serial I/O Module 3 Cabling ............................................................................................................................................................ 4 RJ-45 Cables and Adapters .................................
DS74 Serial I/O Module 4 Cabling RJ-45 Cables and Adapters DS74 EIA-232 RJ-45 Signal Pin EIA 232 Signal Signal Direction Description 1 DTR Out Handshake, Line Driver Inactive State = Low: -12V when port is selected unless programmed differently. Used as a handshake line to enable/disable the receiving of characters.
DS74 Serial I/O Module 5 Adapters RJ08X007 Figures 1 and 2 provide vi sual representation of an RJ-45 receptacle and plug. Serial Setup • Connect the EIA-232 port to a Baytech device via the RJ08X007 rolled flat ribbon cable. • Baytech makes custom cables for som e devices.
DS74 Serial I/O Module 6 Unit Configuration Menu The configuration menu allows the user to choo se wh ich unit they would like to access. Enter the number that corresponds with the Host Module followed by a <c r>. Now the module can be configured as shown.
DS74 Serial I/O Module 7 Status Displays the current configuration of each I/O port. Serial Port Configuration Since the DS74 I/O modules use different serial port configurations. Handshaking, Baud Rate, Word Size, Stop Bits, and Parity can all be configured through the HOS T module using the menus.
DS74 Serial I/O Module 8 Type a number to select the handshaking option and press <cr>. 1. Software Handshaking: This style uses actual d ata bytes as control characters. The lines necessary are TX, Rx, and ground since the control characters are sent over the tran smission line like regular data.
DS74 Serial I/O Module 9 Word Size The word size is the measurement of the actual data bits in a tran sm ission. Which setting you choose depends on what information you are transferring. For ex ample, standard ASCII has values from 0 to 127 (7 bits).
DS74 Serial I/O Module 10 Select 5 ), to get the Parity, Default is None the Host m odule responds: Type a number to select the Parity option and press <cr>. RTS/DTR Line Driver Inactivity State RTS (Request to Send)/ DTR (Data Terminal Ready) is normally used in conj unction with an external modem.
DS74 Serial I/O Module 11 NOTE: Once you make a change to the Port Device Name, you have to back out of the menu and will be asked to Accept changes. If you type ‘y’ for yes, the changes take effect immediately for the serial port. Type ‘Y’ for YES or ‘N’ for NO and press <cr>.
DS74 Serial I/O Module 12 Type ‘Y’ for YES or ‘N’ for NO and press <cr>. Verify DS74 is functioning: A rollover cables (pin out 1-8, 2-7, 3-6, 4-5, 5-4, 6-3, 7-2, 8-1) and a 9-pin adapter (9FRJ45PC-1) and Ethernet or Modem cable. 1. Set up the Host module with modem or Ethernet cables for normal operations.
DS74 Serial I/O Module 13 BayT ech Product W arranty Bay Technical Associates (BayTech) warrants that its products will be free from defects in m aterials and workmanship under normal use for a period of two years fr om date of purchase (or from date of shipm ent from BayTech if proof of purchase is not provided).
DS74 Serial I/O Module 14 Technical Support BayTech offers Tech Support for the lifetime of the produc t. A staff of Applications Engineers is on duty to assist with installation, set up or ope ration issues. Support is available from 8:00 a.m. to 5 p.
DS74 Serial I/O Module 15 Return Authorization Process: 1. Contact BayTech to get a Return Authorization (RA) Number. IMPORTANT: BayTech will not accept any returns without an RA number. 2. Package the unit carefully in its original packagin g or similar packaging.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Bay Technical Associates DS74 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Bay Technical Associates DS74 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Bay Technical Associates DS74, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Bay Technical Associates DS74 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Bay Technical Associates DS74, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Bay Technical Associates DS74.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Bay Technical Associates DS74. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Bay Technical Associates DS74 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.