Document No. 49-0002-013 Rev. A Installation, Operation & Diagnostics for the MIU9.6FPD Industrial Grade, Digital Fast Poll Standalone Modem.
Document No. 49-0002-013 Rev. A Telenetics Corporation 26772 Vista Terrace Drive Lake Forest, California 92630 (949)455-4000 Fax (949)455-4010.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 1 TABLE OF CONTENTS 1. STANDARDS .... ............................................................................ .............. 2 2. PRODUCT OVERVIEW .. .......................
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 2 1. STANDARDS Meets FCC Rules Part J, Subpart 15 , Class A for radi at ed emissions.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 3 2. PR ODUCT OV ERVIEW The MIU9.6FPD is an industri al grade Digi tal Fast Poll m odem designed for multidropping appli cat ions over unconditioned me tallic l ines (eg; pilot wires).
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 4 3. GENERAL PR ODUCT SPECIFICATIONS Dimensions: 5.3 x 4.0 x 1.375 inches Weight: 1 l b Voltage Supply : Standard Model : 40 to 270VDC 40 to 270VAC, 50/60Hz LV Model (Suffix “-LV” ): 9 to 36VDC Current Requirements : 12VDC 24VDC 125V DC 120VAC 220VAC MIU9.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 5 4. MODEM SPECIFICATIONS Modulation: Pulse Position Mo dulation ( PPM) Synch/Async: Asynchronous Only Data Rate: 0 – 1200bps Error Correction: None Data Compression: None Data Modulation Connectivity: Using 16m s Polli ng Test 99.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 6 Other Features Receiver Equali zation: Compromi se Equalizati on Self Test Diagnostics: None Local Analog Loopback: See Secti.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 7 5. METALLIC CONDUCTOR SP ECIFICATIONS The MIU9.6FPD contains di gital c irc ui try for connection 2 or 4-wire metal lic conductors (eg; pilot wires) . The M IU9.6FPD will also interface to Power Line Carrier or Mi crowa ve radio voice c hannel networks.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 8 6. POWER CONNECTIONS.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 9 7. SERIAL DATA PORT PIN-OUTS.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 10 8. DIP SWITCH FUNCTIONS IMPORTANT NOTE: Invert m odem t o vi ew dip switches as shown above Table 1 Switch Function ON OFF S.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 11 9. LED INDICATOR.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 12 10. OUTLINE DRAWING & MOUNTING.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 13 11. DIAGNOSTICS The following pages provide har dware techni ques for diagnosing comm unicati on problems and there by is olating the problem at the local mod e m, th e re mo t e mo d em o r the interconnecting line.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 14 Test 3: Received Signal Level Set Dip Switch 1 OFF (TxA = -10dBm ) and Dip Swit ch 3 OFF (RxA = -43dB m). CD will be ON. Run a test m essage a t TxD and verify that the sam e m essage is receive d at RxD with no data errors.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 15 (c) REMOTE DIGITAL LOOPBACK – 4/Wire Network (Figure 5) Configure both the local and re mote mo de ms a s f oll ow s: Swit.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 16 (d) LINE DIAGNOSTICS (i) Typical m odem configuration for 4-w ire Point-to-Point system… Switch 1 = ON (TxA = 0dBm ) Switch 3 = ON (RxA = -33dBm ) Switch 4 = OFF (RTS/CTS = 1ms) Switch 5 = OFF (RTS/CTS = 1m s) Switch 6 = ON (Constant Carrier m ode).
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 17.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 18.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 19.
MIU9.6FPD Installation, Operation & Diagnost ics April 25, 1998 Page 20 NOTES:.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Telenetics MIU9.6FPD c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Telenetics MIU9.6FPD - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Telenetics MIU9.6FPD, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Telenetics MIU9.6FPD va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Telenetics MIU9.6FPD, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Telenetics MIU9.6FPD.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Telenetics MIU9.6FPD. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Telenetics MIU9.6FPD ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.