Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 1/18 Maxeta iFA S eries DC-DC Power Modules 24V Input, 28V Output, 602W Full Brick The Maxeta iFA series power modules are ideally suited for wireless appli cations to power RF power amplifiers.
Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 2/18 Ordering i nformation: Product Identifier Package Size Platform Input Volt.
Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 3/18 Mechanical Specification : Unless otherwise sp ecified, tolerances are: x.x ± 0.5 m m [x.xx ± 0.02 in.], x.xx ± 0.25 m m [x.
Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 4/18 Pin Assignment : PIN FUNCTION PIN FUNCTION PIN FUNCTION 1 ON/OFF (+) 7 Vou.
Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 5/18 Absolute Maximum Ratings : Stress in excess of Absolu te Maximum Ratings may cause permanent da mage to the device.
Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 6/18 Electrical Data : iFA24021 A280V- 000 t hrou gh - 026: 2 8V, 21.5 A, 602W O utput Characteristic Min Typ Max Unit Notes & Conditio ns Output Voltage Initial Set-poin t 27.
Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 7/18 Electrical Characteristics: iFA24021 A280V- 000 t hrou gh - 026: 28 V, 21.
Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 8/18 Electrical Characteristics: iFA24021 A280V- 000 throu gh - 02 6: 28V, 21. 5 A, 602W Outpu t Output Ripple at Nominal Inp ut Voltage and Full Load, Ta=25 ° C Ch.
Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 9/18 Thermal Perform ance : iFA24021 A280V- 000 t hrou gh - 026: 28 V, 21.5 A, 602W O utput Maximum output current vs. a mbient temperature at nominal input voltage for airflo w rates natural convection 0.
Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 10/18 Thermal Ma nagement: An im portant part of the overall s ystem design proces s is therm al m anagem ent; therm al design m ust be considere d at all levels to ens ure good r eliabilit y and lifetim e of the fina l system .
Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 11/18 Perform ance page f or the p ower m odule of interest. In all conditio ns, the p ower m odule should be op erated be low the m axim um operating tem perature s how n on the derating cur ve .
Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 12/18 Operating I nformation: Outpu t Over-Current Protect ion: T he power m odules are e quipped with current limit, over-c urrent slo w hiccup, a nd over- current trip fas t hiccup m ode protec tion.
Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 13/18 An alternat ive wa y to control ON/O FF is from the output side b y utilizing AUX output pin of the sam e m odule.
Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 14/18 If the output voltage adjustm ent f eature is not used, t he Vout(+) p in shou ld be short ed to the sense( +) pin an d the Vout(- ) pin should be s horted to the sense( -) pin b y jumper wires .
Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 15/18 The output v oltage c an also be adjusted within the sam e range b y applying externa l voltage at the trim pin via a buf fer.
Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 16/18 Auxiliar y Bias Pow er (Optio nal): The iFA series power m odules provide an aux iliar y output, which is ref erenced to th e output sense (-) pin.
Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 17/18 Input/Output Ripple a nd Noise Me asurements: The input reflected ripple i s measured w ith a current probe and oscilloscope.
Advance Dat a Sheet: Maxeta TM iFA Series ©2005 TDK Inno veta Inc. iFA Advance Da tasheet 6/6/2005 ℡ (877) 498 - 0099 18/18 To pres erve max imum flexibilit y, the power modules ar e not intern ally fus ed. An external input line norm al blo w fuse with a maxim um value of 40 A is requ ired by safet y agencies.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté TDK Maxeta iFA Series c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du TDK Maxeta iFA Series - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation TDK Maxeta iFA Series, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le TDK Maxeta iFA Series va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le TDK Maxeta iFA Series, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du TDK Maxeta iFA Series.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le TDK Maxeta iFA Series. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei TDK Maxeta iFA Series ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.