Manuel d'utilisation / d'entretien du produit GW Dataport Command Interface D13202 du fabricant TANDBERG
Aller à la page of 32
Thi s docume nt i s no t to be re prod uced in w hol e or i n part with out the perm ission in writing from : TAND BE RG T ANDBER G GW Data port Comm and Interfa ce U ser Guide Softw a re version G1.
TANDB E RG G W Datapo rt Comman d I nt er face User G uide D13202 Rev 01 2 Table o f Conten ts 1. INT RODUCTIO N .......... ........ ........ ....... ........ ............ ....... ........ ....... ........ ............ ....... ........ ............ 3 2.
TANDB E RG G W Datapo rt Comman d I nt er face User G uide D13202 Rev 01 3 1. Introduction The TANDBERG GW Datapo rt Comma nd Interface Use r Guide contains guideli nes on how to use t he textual command interface suppor ted by th e GW.
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 4 2. Connectin g to the D a taport Comm a nd Interface through th e RS-232 p o rt. Th e RS- 232 po rt is a 9 -pin, female, D- sub conn ector l oca ted on t he back of the GW. Th e port is configured as a DCE (Data Communications Eq uipment ) .
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 5 2.2. Configuring The Dataport From The Web Interface Cl ic k on System Config uration tab and then the Dataport button. The Dataport can be configured b y setting baudr ate, parit y, databits and st opbi ts.
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 6 3. Connectin g to the D a tport Com mand I nterface u sin g Telnet The TANDBER G GW has two LAN port s. Co nnection to the Datapor t Command Int erface via Telnet should be done through LAN port 1.
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 7 4. The TANDBERG GW Commands 4.1. Introduction Typing ‘ ? ’ or ‘ help ’ when connected to the Dataport Command Interfac e wil l r eturn a list of valid comman ds. The commands are used to control the functi ons of the GW.
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 8 case where the user is trying to transfer a call f r om an inactive GW port (the user input is shown in bold). calltra nsfer 1 999999 *R Inva lid gateway id ERROR Parameter S etti ng Commands are commands that set a system parameter to a sp e cific value.
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 9 4.2.1. System Configuration Comm ands Comman d: Descript ion: defvalue s set This command is used to resto re factory def ault settings. Is s uing this command with no parameters will restore all settings except network settings and option key.
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 10 Examp le of ipaddress fe edb ack : *P ipaddress 1 static 10.0.5.98 *P ipaddress 1 subnetmask 255.255.0.0 *P ipaddress 1 gateway 10.0.0.1 ipassi gnme nt Sele cts bet w ee n DH C P (D yna mi c Hos t Co nf i gur ati on P r ot o c ol) or sta ti c IP addr e s s allo cation.
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 11 best a vai lab le sett in g. Examp le of ipspeed feedback: *P ipspeed 1 auto ipqos Configures the different Quality of Service (QoS) algorithms suppo rted by the TANDBERG GW. Q oS are used to set priorit y on QoS en able d IP networks.
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 12 Examp le of ipq os feedb a c k: *P ipqos prect lp h audio auto *P i p qos diffstlph audio 0 *P ipqos pr ecvtlph audio auto *P ip.
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 13 --- par amet er s: • profil e number: p1 /p2/p3/p4/ p5/p6 . Th e GW can hold as ma n y as six profiles ( p1 , p2 and p3 are predefined and can no t be changed). • call pr ef ix: T he pr ef i x nu mbe r for t hi s pr of i le.
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 14 prichan <PRI interface> lo w <1..23 / 31> or prichan <PRI interface> high <1..23/3 1> or prichan <PRI interface> s e arch <h i gh/ l ow> --- par amet er s: • PRI interface: a/b/c /d .
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 15 o euro - Euro ISDN Examp le of prinet feedback: *P pr i net att prinu mbrange Defines the PRI number range fo r the various PRI interfaces . prin u mbrange <P RI interface> <lowes t nu mber> < highest num ber> --- par amet er s: • PRI interface: a/b/c /d .
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 16 *P service s http on *P serv ice s http s on *P servic e s snmp on *P servic e s ftp on se ndnum Enables/disables broadcast of the lo ca l unit’s number during H.320 ca ll setup.
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 17 Examp le of sport feedback: *P sport 9600 n 8 1 syste mname Sets t he GW nam e.
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 18 4. 2.2. G ene r al GW Comm ands Command: Desc ripti on: call transfer Disconnects t he h323 terminal of a GW call and reconnects to another h323 terminal, by ei t her spec ifying a tele p hone number or by referring to a direc t or y entry .
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 19 disc < gwid> --- pa rame ters: • gwid : 1. . 16. Identifier ref erring to a GW call.
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 20 gwh323ser vice <id> servprefix <e 164prefix> or gwh323service <id> maxbw <bw> or gwh323ser vice <id&g.
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 21 or gwsetti ngs duovi deo <o n/off > or gwsettings encry ption <on/off > sub-c ommand s: • natvid : Sets natural vid e o supp ort to on o r off.
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 22 4.2.3. System Status Comm and s Comman d: Descript ion: callhi story Used t o list c all related information fo r the las t 20 calls. callh i story [logid] St at us fo rmat: callhistory <logid> <lo gtag> < gwlo gtag> <remote nu mb.
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 23 chan st at Us ed to lis t ch anne l sta tus in form ation fo r the PRI int erfa ce.
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 24 • h323 callid: The cal l id o f the h323 terminal • h323 termnumber: Th e nu mber of the h323 termin al Exampl e o f gwcalls fee dba ck: *S gwcalls 1 1 22222222 2 66666 666 h323gkstatus R etu rns cu rre nt g atek e epe r st atu s.
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 25 off 0 ipcall stat isti cs Retu r ns IP dy na mic information fo r all activ e ip cal ls.
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 26 • PRI in terface: a/b/c /d. Letters identi f ying the di f ferent PRI interfaces.
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 27 • vidres: unknown / cif / qcif / sqc if / 4cif / sif / 4sif / vga / svga / xga • duores: cif / qcif / sqcif / 4ci f / sif / .
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 28 4.2.4. Debug Commands Command: Desript ion: even tl og The eventlog records all serious erro rs regist ered by the s y st em. The log can be used to identify the cause for erro r s.
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 29 6 146.172.254.249 (40 ms) 7 146.172.248.5 (40 ms) 8 146.172.248.9 (40 ms) 9 146.172.248.1 (40 ms) 10 146.172.248.62 (40 ms) 11 217.70.229.33 (40 ms) 12 213.248.78.1 (40 ms) 13 213.
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 30 4. 2.5. S pec ial Com man ds Command: Descri ption: boot Reboots the sy stem. boot disp para m Lists all parameter settings. dis pparam fee dbac k Tu rns feed back on sy stem chan ges on / o ff.
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 31 4.3. Parameter Storage Parameters are set by issuing Para meter Sett ing Co mmands, ref. ch apte r 4.1 .2 . All parameters and their co r re sponding storage type a re listed in the table b e low.
TANDB E RG GW Dataport Comm an d Interface Use r Guide D13202 Rev 01 32 4.4. Index Commands boot, 30 callhistory, 22 callst atus, 22 calltrans fer, 18 chanstat , 23 defval ues set , 9 dir e c tor y, 1.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté TANDBERG GW Dataport Command Interface D13202 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du TANDBERG GW Dataport Command Interface D13202 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation TANDBERG GW Dataport Command Interface D13202, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le TANDBERG GW Dataport Command Interface D13202 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le TANDBERG GW Dataport Command Interface D13202, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du TANDBERG GW Dataport Command Interface D13202.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le TANDBERG GW Dataport Command Interface D13202. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei TANDBERG GW Dataport Command Interface D13202 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.