® A+ SER VER 2022G-URF S UPER USER’S MANUAL Revision 1.0f.
The information in this User ’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates.
Preface iii Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the A+ SERVER 2022G-URF . Installation and maintainance should be performed by experienced technicians only .
A+ SERVER 2022G-URF User's Manual iv Chapter 6: Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC825TQ-R720UB server chassis.
Preface v Contents Chapter 1 Introduction 1-1 Overview ......................................................................................................... 1-1 1-2 Serverboard Features .............................................................
A+ SERVER 2022G-URF User's Manual vi Installing The Inner Rails on the Chassis ....................................................... 2-6 Installing the Outer Rails on the Rack ............................................................ 2-7 Standard Chassis Installation .
Preface vii 5-2 Processor and Heatsink Installation ................................................................ 5-2 Installing a Passive CPU Heatsink ................................................................. 5-4 5-3 Connecting Cables ....
A+ SERVER 2022G-URF User's Manual viii 6-4 Drive Bay Installation/Removal ....................................................................... 6-4 Accessing the Drive Bays .......................................................................
Chapter 1 Introduction 1-1 Overview The A+ SERVER 2022G-URF is a high-end server comprised of two main subsystems: the SC825TQ-R720UB 2U server chassis and the H8DGU-F dual processor serverboard. Please refer to our web site for information on operating systems that have been certied for use with the system (www .
1-2 A + SE R VER 2022G-URF User's Manual • Product safety information: http://super-dev/about/policies/safety_information.cfm For support, email support@supermicro.com. 1-2 Serverboard Features At the heart of the A+ SERVER 2022G-URF lies the H8DGU-F , a dual processor serverboard based on the AMD SR5670/SP5100 chipset.
Chapter 1: Introduction 1-3 Onboard Controllers/Ports The color-coded I/O ports include two COM ports (one header and one port), a VGA (monitor) port, Seven USB 2.0 ports (2x rear , 4x header , 1x type A), PS/2 mouse and keyboard ports, two gigabit Ethernet ports and one dedicated IPMI LAN port.
1-4 A + SE R VER 2022G-URF User's Manual Front Control Panel The control panel on the A+ SERVER 2022G-URF provides you with system monitoring and control. LEDs indicate system power , HDD activity , network activity , system overheat and power supply failure.
Chapter 1: Introduction 1-5 Figure 1-1. AMD SR5670/SP5100 Chipset: System Block Diagram Note: This is a general block diagram. Please see Chapter 5 for details. AMD Socket G34 CPU2 DIMM A0 DIMM A1 DIMM A1 DIMM A0 HT3 Link (8+8)x(8+8)-3.2GT/s HT3 Link 16x16-5.
1-6 A + SE R VER 2022G-URF User's Manual 1-4 Contacting Supermicro Headquarters Address: Super Micro Computer , Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. T el: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.
Chapter 2: Server Installation 2-1 Chapter 2 Server Installation 2-1 Overview This chapter provides a quick setup checklist to get your A+ SERVER 2022G-URF up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time.
2-2 A+ SERVER 2022G-URF User's Manual • This product is for installation only in a Restricted Access Location (dedicated equipment rooms, service closets and the like). • This product is not suitable for use with visual display work place devices acccording to §2 of the the German Ordinance for Work with V isual Display Units.
Chapter 2: Server Installation 2-3 Rack Mounting Considerations Ambient Operating T emperature If installed in a closed or multi-unit rack assembly , the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room.
2-4 A+ SERVER 2022G-URF User's Manual 2-5 Installing the System into a Rack This section provides information on installing the chassis into a rack unit with the rails provided. There are a variety of rack units on the market, which may mean that the assembly procedure will differ slightly from the instructions provided.
Chapter 2: Server Installation 2-5 Figure 2-2. Extending and Releasing the Inner Rail Locking T abs Each inner rail has a locking tab. This tab locks the chassis into place when installed and pushed fully into the rack. These tabs also lock the chassis in place when fully extended from the rack.
2-6 A+ SERVER 2022G-URF User's Manual Figure 2-3. Installing the Inner Rails Installing The Inner Rails on the Chassis Installing the Inner Rails 1.
Chapter 2: Server Installation 2-7 Figure 2-5. Extending and Releasing the Outer Rails 1 1 1 2 1 3 1 4 21D01 L-min=676.00(26.61")(outer rail) Installing the Outer Rails on the Rack Installing the Outer Rails 1. Press upward on the locking tab at the rear end of the middle rail.
2-8 A+ SERVER 2022G-URF User's Manual Figure 2-6. Installing into a Rack Ball-Bearing Shuttle Standard Chassis Installation Stability hazard. The rack stabilizing mechanism must be in place, or the rack must be bolted to the oor before you slide the unit out for servicing.
Chapter 2: Server Installation 2-9 2-6 Checking the Serverboard Setup After you install the 2022G-URF in the rack, you will need to open the unit to make sure the serverboard is properly installed and all the connections have been made. Accessing the inside of the System 1.
2-10 A+ SERVER 2022G-URF User's Manual Figure 2-7. Accessing the Inside of the System.
Chapter 2: Server Installation 2-1 1 2-7 Checking the Drive Bay Setup Next, you should check to make sure the peripheral drives and the SAS/SA T A drives have been properly installed and all connections have been made. Checking the Drives 1. All drives are accessable from the front of the server .
2-12 A+ SERVER 2022G-URF User's Manual Notes.
Chapter 3: System Interface 3-1 Chapter 3 System Interface 3-1 Overview There are several LEDs on the control panel as well as others on the drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specic components.
A+ SERVER 2022G-URF User's Manual 3-2 3-3 Control Panel LEDs The control panel located on the front of the chassis has several LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take.
Chapter 3: System Interface 3-3 1 2 NIC1 Indicates network activity on the LAN1 port when ashing. NIC2 Indicates network activity on the LAN2 port when ashing. HDD On the A+ SERVER 2022G-URF , this LED indicates hard drive and/or DVD-ROM drive activity when ashing.
A+ SERVER 2022G-URF User's Manual 3-4 3-4 Drive Carrier LEDs Each drive carrier has two LEDs: SA T A Drives • Green: Whe n ill umin ated, t he green LED on the SA T A dr i ve ca rr i er in dic ate s dr ive ac tiv it y.
4-1 Chapter 4: W arning Statements for AC Systems Chapter 4 Standardized W arning Statements for AC Systems 4-1 About Standardized W arning Statements The following statements are industry standard warnings, provided to warn the user of situations which have the potential for bodily injury .
4-2 A+ SERVER 2022G-URF User's Manual W arnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr . Sie benden sich in einer Situation, die zu V erletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen V erfahren zur V orbeugung vor Unfällen vertraut.
4-3 W arning Statements for AC Systems 안전을 위한 주의사항 경고! 이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다.
4-4 A+ SERVER 2022G-URF User's Manual Installation Instructions W arning! Read the installation instructions before connecting the system to the power source. W arnung V or dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen.
4-5 Chapter 4: W arning Statements for AC Systems Circuit Breaker W arning! This product relies on the building's installation for short-circuit (overcurrent) protection.
4-6 A+ SERVER 2022G-URF User's Manual Power Disconnection W arning 電源切断の警告 システムコン ポ ー ネ ン トの 取り付 けまた は 取り外しの た め に 、 シャ.
4-7 Chapter 4: W arning Statements for AC Systems ¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema.
4-8 A+ SERVER 2022G-URF User's Manual Equipment Installation 機器の設置 ト レ ー ニ ン グを受け認 定さ れた人だけが こ の 装 置の 設 置、 交 換、 ま たはサ.
4-9 Chapter 4: W arning Statements for AC Systems ア ク セ ス制限区域 こ のユニ ッ ト は 、 ア ク セ ス制限区域に 設置 さ れ る こ と を想定 し て い ま す 。 .
4-10 A+ SERVER 2022G-URF User's Manual Battery Handling W arning! There is the danger of explosion if the battery is replaced incorrectly . Replace the battery only with the same or equivalent type recommended by the manufacturer .
4-1 1 Chapter 4: W arning Statements for AC Systems W arnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr . Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers.
4-12 A+ SERVER 2022G-URF User's Manual W arnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom zugeführt wird, müssen alle V erbindungen entfernt werden. ¡Advertencia! Puede que esta unidad tenga más de una conexión para fuentes de alimentación.
4-13 Chapter 4: W arning Statements for AC Systems Backplane V oltage バッ ク プレ ーン の 電 圧 シ ス テ ムの稼 働中は危 険な電 圧 ま たは電力 が、 バ ッ ク プ レ .
4-14 A+ SERVER 2022G-URF User's Manual Comply with Local and National Electrical Codes W arning! Installation of the equipment must comply with local and national electrical codes.
4-15 Chapter 4: W arning Statements for AC Systems Product Disposal W arning! Ultimate disposal of this product should be handled according to all national laws and regulations. יצראה למשחה יקוח םואית !הרהזא תנקתה םייצראהו םיימוקמה למשחה יקוחל תמאות תויהל תביי ח דויצה .
4-16 A+ SERVER 2022G-URF User's Manual W aarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming met alle nationale wetten en reglementen. ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales.
4-17 Chapter 4: W arning Statements for AC Systems W arnung Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger , Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt.
4-18 A+ SERVER 2022G-URF User's Manual W arning! When installing the product, use the provided or designated connection cables, power cables and AC adaptors.
4-19 Chapter 4: W arning Statements for AC Systems Attention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné. L'utilisation d'autres cables et adaptateurs peut provoquer un dysfonctionnement ou un incendie.
4-20 A+ SERVER 2022G-URF User's Manual Notes.
Chapter 5: Advanced Serverboard Setup 5-1 Chapter 5 Advanced Serverboard Setup Thi s ch apter c over s t he ste ps re quir ed to i nst all p ro ce ss or s and h eat sin ks to th e H8DGU-F ser ver boa rd, c on nec t th e dat a and p owe r ca ble s and i nst all a dd - o n ca rds .
5-2 A + SE R V ER 2022G-URF User 's Manual 5-2 Processor and Heatsink Installation IMPORT ANT! A l w a y s c o n n e c t t h e p o w e r c o r d l a s t a n d r e m o v e i t r s t b e f o r e addi ng, re mov ing o r ch angi ng any ha rd ware c om po nent s.
Chapter 5: Advanced Serverboard Setup 5-3 T riangle 3. Use your thumb and your index nger to hold the CPU. Locate and align pin 1 of the CPU socket with pin 1 of the CPU. Both are marked with a triangle. 4. Align pin 1 of the CPU with pin 1 of the socket.
5-4 A + SE R V ER 2022G-URF User 's Manual Installing a Passive CPU Heatsink 1. Do not apply any thermal grease to the heatsink or the CPU die -- the required amount has already been applied. 2. Place the heatsink directly on top of the CPU so that the heat sink screws are aligned with the mounting holes on the back plate.
Chapter 5: Advanced Serverboard Setup 5-5 5-3 Connecting Cables Now that the processors are installed, the next step is to connect the cables to the serverboard. These include the data (ribbon) cables for the peripherals and control panel and the power cables.
5-6 A + SE R V ER 2022G-URF User 's Manual Figure 5-1. Front Control Panel Header Pins (JF1) 5-4 I/O Ports The I/O ports are color coded. See Figure 5-2 below for the colors and locations of the various I/O ports. Figure 5-2. Rear Panel I/O Ports 1 2 5 4 3 6 7 8 Rear I/O Ports 1.
Chapter 5: Advanced Serverboard Setup 5-7 5-5 Installing Memory Figure 5-3. Installing DIMM into Slot Caution : Exercise extreme care when installing or removing DIMM modules to prevent any possible damage. Installing Memory Modules 1. Insert the desired number of DIMMs into the memory slots, starting with DIMM 1A.
5-8 A + SE R V ER 2022G-URF User 's Manual Memory Support The H8DGU(-F) serverboard supports single/dual/tri/quad-channel, DDR3-1600/1333/1066 Mhz registered ECC/Unbuffered ECC/non-ECC SDRAM.
Chapter 5: Advanced Serverboard Setup 5-9 Note 1 : Due to OS limitations, some operating systems may not show more than 4 GB of memory . Note 2 : Due to memory allocation to system devices, the amount of memory that remains available for operational use will be reduced when 4 GB of RAM is used.
5-10 A + SE R V ER 2022G-URF User 's Manual 5-6 Adding PCI Expansion Cards PCI Expansion Slots One riser card is used to support PCI expansion cards in the system. The RSC- R2UU-UA3E8+ riser card can support one UIO card and three full-height, full-length PCI-Express x8 expansion cards.
Chapter 5: Advanced Serverboard Setup 5-1 1 Figure 5-4. SUPER H8DGU-F Layout (not drawn to scale) 5-7 Serverboard Details Notes: Jumpers not indicated are for test purposes only. When LE1 LED is on, the onboard power connection is on. Make sure to unplug the power cables before removing or installing components.
5-12 A + SE R V ER 2022G-URF User 's Manual H8DGU(-F) Quick Reference Jumper Description Default Setting JBT1 CMOS Clear (See Section 5-9) JI2C1/JI2C2 I2C to PCI-E Slot Enable/Disable Both Open (.
Chapter 5: Advanced Serverboard Setup 5-13 5-8 Connector Denitions Power Connectors A 20-pin main power supply connector(JPW1) and two 8-pin CPU PWR connectors (JPW2/JPW3) on the motherboard. These power connectors meet the SSI EPS 12V specication.
5-14 A + SE R V ER 2022G-URF User 's Manual NIC2 (LAN2) LED The LED connections for LAN2 are on pins 9 and 10 of JF1. Attach LAN LED cables to display network activity . See the table on the right for pin denitions. HDD LED The HDD LED connection is located on pins 13 and 14 of JF1.
Chapter 5: Advanced Serverboard Setup 5-15 Universal Serial Bus Ports T wo Universal Serial Bus ports (USB 2.0) are located beside the Keyboard and Mouse PS2 ports. One additional T ype A port (USB6) is included on the motherboard. See the table on the right for pin denitions.
5-16 A + SE R V ER 2022G-URF User 's Manual T -SGPIO The T -SGPIO1/ T -SGPIO2 (Serial General Purpose Input/Output) headers provide a bus between the SA T A controller and the backpane to provide SA T A enclosure management functions.
Chapter 5: Advanced Serverboard Setup 5-17 A TX PS/2 Keyboard and PS/2 Mouse Ports The A TX PS/2 keyboard and PS/2 mouse are located next to the Back Panel USB Ports 0~3 on the motherboard.
5-18 A + SE R V ER 2022G-URF User 's Manual Compact Flash Card PWR Connector A Compact Flash Card Power Connector is located at JWF1. For the Compact Flash Card to work properly , you will need to enable with JCF1 and connect a Compact Flash Card power cable to JWF1 rst.
Chapter 5: Advanced Serverboard Setup 5-19 T rusted Platform Module Header The JTPM1 header is used to connect a T rusted Platform Module (TPM), available separately from a third-party vendor .
5-20 A + SE R V ER 2022G-URF User 's Manual 5-9 Jumper Settings Explanation of Jumpers T o modify the operation of the motherboard, jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function of the connector .
Chapter 5: Advanced Serverboard Setup 5-21 VGA Enable/Disable JPG1 allows you to enable or disable the VGA port. The default position is on pins 1 and 2 to enable VGA.
5-22 A + SE R V ER 2022G-URF User 's Manual 5-10 Onboard Indicators LAN1/LAN2 LEDs The Ethernet ports (located beside the VGA port) have two LEDs. On each Gb LAN port, one LED blinks to indicate activity while the other may be green, amber or off to indicate the speed of the connection.
Chapter 5: Advanced Serverboard Setup 5-23 5-1 1 SA T A Drive Connecti ons SA T A Ports There are no jumpers to congure the SA T A ports, which are designated SA T A0 through SA T A5 .
5-24 A + SE R V ER 2022G-URF User 's Manual 5-12 Enabling SA T A RAID Now that the hardware is set up, you must install the operating system and the SA T A RAID drivers, if you wish to use RAID with your SA T A drives.
Chapter 5: Advanced Serverboard Setup 5-25 Figure 5-5. BIOS Setup Screen Enabling SA T A RAI D in the BIOS Before installing the Windows operating system, you must change some settings in the BIOS. Boot up the system and hit the <Delete> key to enter the BIOS Setup Utlility .
5-26 A + SE R V ER 2022G-URF User 's Manual Figure 5-7. Adaptec RAID Utility Program Screen Using the DotHill and Adaptec RAID Utility The RAID Utility program allows you to dene the drives you want to include in the RAID array and the mode and type of RAID.
Chapter 5: Advanced Serverboard Setup 5-27 Installing the RAID Driver During OS Installation Y ou may also use the procedure below to install the RAID driver during the Windows OS installation: 1. With the Windows OS installation CD-ROM in the CD drive, restart the system.
5-28 A + SE R V ER 2022G-URF User 's Manual Figure 5-8. Driver/T ool Installation Display Screen Note: Click the icons showing a hand writing on paper to view the readme les for each item. Click the computer icons to the right of these items to install each item (from top to the bottom) one at a time.
Chapter 5: Advanced Serverboard Setup 5-29 Figure 5-9. SuperDoctor III Interface Display Screen (Health Information) Note: The SuperDoctor III program and User ’s Manual can be downloaded from the Supermicro web site at http://www .supermicro.com/products/accessories/software/ SuperDoctorIII.
5-30 A + SE R V ER 2022G-URF User 's Manual 5-14 Serverboard Battery Caution : There is a danger of explosion if the onboard battery is installed upside down, which will reverse its polarites (see Figure 5-1 1). This battery must be replaced only with the same or an equivalent type recommended by the manufacturer (CR2032).
Chapter 6: Advanced Chassis Setup 6-1 Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform maintenance on the SC825TQ-R720UB chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered.
6-2 A+ SERVER 2022G-URF User's Manual Figure 6-1. Front and Rear Chassis Views 6-2 Control Panel The control panel (located on the front of the chassis) must be connected to the JF1 connector on the serverboard to provide you with system status indications.
Chapter 6: Advanced Chassis Setup 6-3 6-3 System Fans Three 8-cm hot-swap fans provide the cooling for the system. It is very important that the chassis top cover is properly installed and making a good seal in order for the cooling air to circulate properly through the chassis and cool the components.
6-4 A+ SERVER 2022G-URF User's Manual W arning! Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers. For information on recommended HDDs, visit the Supermicro Web site at http://www .supermicro.com/products/nfo/files/storage/SAS-1- CompList-1 10909.
Chapter 6: Advanced Chassis Setup 6-5 SAS/SA T A Drive Install ation These drives are mounted in carriers to simplify their installation and removal from the chassis. The carriers also help promote proper airow for the drives. For this reason, even empty carriers without hard drives installed must remain in the chassis.
6-6 A+ SERVER 2022G-URF User's Manual Figure 6-4. Removing a SAS/SA T A Drive Carrier Important: All of the drive carriers must remain in the drive bays to maintain proper cooling airow. Release Button Hard Drive Backplane The hard drives plug into a backplane that provides power , drive ID and bus termination.
Chapter 6: Advanced Chassis Setup 6-7 DVD-ROM Installation The top cover of the chassis must be opened to gain full access to the DVD-ROM drive bay . The 2022G-URF accomodates only slim type DVD-ROM drives. Side mounting brackets are typically needed to mount a slim DVD-ROM drive in the server .
6-8 A+ SERVER 2022G-URF User's Manual 6-5 Power Supply The A+ SERVER 2022G-URF has a 720 watt redundant power supply consisting of two power modules. Each power supply module has an auto-switching capability , which enables it to automatically sense and operate at a 100V - 240V input voltage.
Chapter 7: BIOS 7-1 Chapter 7 BIOS 7-1 Introduction This chapter describes the AMI BIOS Setup Utility for the A+ SERVER 2022G-URF . The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated. This chapter describes the basic navigation of the AMI BIOS Setup Utility setup screens.
7-2 A + SE R V ER 2022G-URF User 's Manual System Time/System Dat e Y ou can edit this eld to change the system time and date. Highlight System Time or System Date using the <Arrow> keys. Enter new values through the keyboard. Press the <T ab> key or the <Arrow> keys to move between elds.
Chapter 7: BIOS 7-3 W atch Dog Function Allows system to restart when system is inactive more than 5-minutes. The options are Enabled and Disabled . Power Button Function This sets the function of the power button when you turn off the system. Options include 4-second Overide and Instant Off .
7-4 A + SE R V ER 2022G-URF User 's Manual Power Cap This option can decide the highest P-state in the OS. Options include P-state 0 through P-state 4. ACPI SRA T T able This option Enables or Disables the building of the ACPI SRA T T able. CPU Down Core This option sets down core support for the CPU.
Chapter 7: BIOS 7-5 Bank Swizzle Mode This setting Enables or Disables the bank swizzle mode. ECC Conguration ECC Mode This submenu affects the DRAM scrub rate based on its setting. Options include Disabled, Basic , Good, Super , Max and User .
7-6 A + SE R V ER 2022G-URF User 's Manual Legacy USB Support Select "Enabled" to enable the support for USB Legacy . Disable Legacy support if there are no USB devices installed in the system. "Auto" disabled Legacy support if no USB devices are connected.
Chapter 7: BIOS 7-7 Select "Disabled" to allow the data to be transferred from and to the device one sector at a time. Select "Auto" to allows the data transfer from and to the device occur multiple sectors at a time if the device supports it.
7-8 A + SE R V ER 2022G-URF User 's Manual PCI/PnP Conguration Clear NVRAM Select Y es to clear NVRAM during boot-up. The options are Y es and No . Plug & Play O/S Select Y es to allow the OS to congure Plug & Play devices. (This is not required for system boot if your system has an OS that supports Plug & Play .
Chapter 7: BIOS 7-9 SuperIO Device Conguration Serial 1 Address This option species the base I/O port address and Interrupt Request address of serial port 1. Select "Disabled" to prevent the serial port from accessing any system resources.
7-10 A + SE R V ER 2022G-URF User 's Manual Redirection After BIOS POST Options are Disable (no redirection after BIOS POST), Boot Loader (redirection during POST and during boot loader) and Always (redirection always active). Note that some OS's may not work with this set to Always.
Chapter 7: BIOS 7-1 1 ACPI Conguration PS2 KB/MS W akeup This setting allows you to Enable or Disable PS2 keyboard and mouse wakeup. ACPI Aware O/S This setting Enables or Disables ACPI support for the system's operating system. Options include Ye s (enabled) or No (disabled).
7-12 A + SE R V ER 2022G-URF User 's Manual IP Address Source Select the source of this machine's IP address. If Static is selected, you will need to know and enter manually the IP address of this machine below .
Chapter 7: BIOS 7-13 Event Log Conguration View Event Log Pressing the Enter key will open the event log. Use the " h " and " i " keys to navigate through the system event log. Mark All Events as Read Selecting this and pressing the Enter key marks all events as read in the event log.
7-14 A + SE R V ER 2022G-URF User 's Manual 7-5 Boot Menu Boot Device Priority This feature allows you to prioritize the boot sequence from the list of available devices. A device that is in parenthesis has been disabled in the corresponding type menu.
Chapter 7: BIOS 7-15 7-6 Exit Menu Select the Exit tab from AMI BIOS Setup Utility screen to enter the Exit BIOS Setup screen. Save Changes and Exit When you have completed the system conguration changes, select this option to leave BIOS Setup and reboot the computer , so the new system conguration parameters can take effect.
7-16 A + SE R V ER 2022G-URF User 's Manual Notes.
A-1 Appendix A: BIOS Error Beep Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-T est) routines, which are performed each time the system is powered on, errors may occur . Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process.
A-2 A + SE R V ER 2022G-URF User 's Manual Notes.
Appendix B: Installing Windows B-1 Appendix B Installing Windows After all hardware components have been installed, you must rst congure Intel South Bridge RAID Settings before you install the Windows OS and other software drivers. T o congure RAID settings, please refer to RAID Conguration User Guides posted on our web site at www .
B-2 A + SE R V ER 2022G-URF User 's Manual B-2 Installing the Windows OS for a Non-RAID System 1. Insert Microsoft's Windows XP/Windows 2003/Windows 2008/Windows Vista Setup CD in the CD drive, and the system will start booting up from CD. 2.
Appendix C: System Specications C-1 Appendix C System Specications Processors Dual AMD Opteron 6000 series (AMD Socket G34 type) processors Note: Y ou must install at least two processors for full functions to be supported. Note: Please refer to our web site for a complete listing of supported processors.
C-2 A + SE R V ER 2022G-URF User 's Manual Ex pansion Slots One UIO controller card slot and three PCI Express 2.0 x8 slots for standard size add-on cards Serverboard H8DGU-F (Proprietary form factor) Dimensions: 12.28" x 13.05" (312 x 331 mm) Chassis SC825TQ-R700UBP(2U rackmount) Dimensions: (WxHxD) 16.
Appendix C: System Specications C-3 Regulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/- 3-3, CISPR 22 Class A Electromagnetic Immunity: EN 55024/CISPR 24,.
C-4 A + SE R V ER 2022G-URF User 's Manual (continued from front) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear fac.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté SUPER MICRO Computer 2022G-URF c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du SUPER MICRO Computer 2022G-URF - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation SUPER MICRO Computer 2022G-URF, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le SUPER MICRO Computer 2022G-URF va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le SUPER MICRO Computer 2022G-URF, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du SUPER MICRO Computer 2022G-URF.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le SUPER MICRO Computer 2022G-URF. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei SUPER MICRO Computer 2022G-URF ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.