Manuel d'utilisation / d'entretien du produit X4200 M2 du fabricant Sun Microsystems
Aller à la page of 48
Netra TM X4200 M2 Server Just the Facts SunWIN token #496298 June 2007 Version 1.2.
Copyrights © 2006 Sun Microsyste ms, Inc. All Rights Reserved. Sun, Sun Microsystems, the Sun logo, IPX, Customer Ready Systems, Netra, N1, ONC, Solaris, Sun Fire, Sun StorEdge, SunSpectrum, and SunVTS are trademarks or registere d trademarks of Sun Microsystems, Inc.
Table of Contents Positioning ............. ..................... ..................... ..................... ............. ..................... ..................... ..................... .............5 Introduction .................. ..............
Standard Configurations – Preconfigured System s.......... ................. ................. ................. ........... ................. .......34 Netra X4200 M2 Ser ver XATO Chassis Options: ...................................................
Positioning Introd uction Deregulation and privatization ha s created intense competition in the worldwid e telecommunications market over the past few years. The marketplace continues to evolve as voice and data solutions become more integrated and next-generation wireless, video and messaging technol ogies emerge.
Key Me ssag es The Netra X4200 M2 server delivers dramatic performance and flexibility along with space and power efficiency to meet the increasing demands of the ne twork infrastructure.
● Netra ba sed servers are used around the globe in a variety of locat ions inc luding telecommu nications central offic es and wireless base statio ns, Interne t data centers, metropolitan area networks, POPs, and enterprise service provider infrastructur es.
Feature Function Benefit • DDR2/667 memory with ECC • ECC helps to ensure data integrity with a utomatic error correction in case a single bit is affected by such events as alpha particle hitting .
Feature Function Benefit • Four onboard 10/100/1000-Mbps Ethernet ports • Exceptional I/O perf ormance and increased network reliability by providing redundancy • Increases network efficiency, f.
Feature Function Benefit 1. Bare-metal discovery 2. firmware updating 3. OS patching 4. OS Provisioning 5. Monitoring 6. Event logging commands, vastly reducing administrator overhead.
Feature Netra X 4200 M2 Server Sun Fire X4200 M2 Server Four USB 1.1 port s PCI Three PCI- X slots, f ull height, 2x full length, 1x half height One PCI-E slot, MD2 low pr ofile Four P CI-E slots, MD2.
Feature Netra X 4200 Netra T2000 Netra 240 Netra 440 146-GB (w/o DVD ) 2.5” SAS HDDs (w/o DVD ) 2.5” SAS HDDs Removabl e media Tray Load DVD/R W Tray Load D VD/RW Slimline DVD/RW Slimline DVD/RW Interfaces Dual USB 2.0 ports, 1 x 10MB/s Ethernet, one serial Dual USB 1.
• Base Station Controlle r (BSC) • Content Distribution Networks • DNS Services • Firewall (VPN/IPSEC) • IP Traffic management • Security • Streaming Media • Defense/Military /Intellig.
Selling Highlights Marke t Value Propo sition • The Netra X4200 M2 server delivers dramatic performanc e and flexibility along with space and power efficiency to meet the increasing demands of the ne twork infrastructure.
Enabling Technology Next-G enera tion AMD Opte ron Pro cess or Basi cs The Next-Generation AMD Opteron processor leverages the same proven Di rect Connect Architectu re and CMP (Chip- level Multi-Proc.
HyperTransport TM Technology The Next-Generation AMD Opteron processor continues to use HyperTranspor t Technology links to provide a scalable bandwidth interconnect among process ors, I/O subsystem s, and other chip sets.
Figur e 3: Samp le Hy perTra nsport Tech nology Inte rconnec t Bloc k New Next-Generation AMD Opteron Processor Enhancements The Next-Generation AMD Opteron P rocessor Design for S ocket F (1207) (for.
For AMD PowerNow technology to work, b oth the oper ating system and server BIOS must be qualified to run AMD's PowerNow . Please see below for specific product support. Solaris Support for Power Now! Solaris Engineering is currently a ggressively working to add PowerNow support.
System Architecture Overv iew Figure 4. Netra TM X4200 M2 s erver block diagra m The Netra TM X4200 M2 server comes with the following major components: • The Next-Generation AMD Opteron 2214 HE (em.
Overv iew The Netra X4200 M2 server features two CPU sockets that support Next-Generation A MD Opteron, model 2214 HE ( L1 socket) embedded class processors. The server is suppo rted with one or two processors and each processor controls 2 pairs of D IMM slots, for a total of eight DIMM in a two CPU system.
Internal Hard Disk I/O Subsystem The Netra X4200 M2 server supports up to four hard di sk drives, controlled by an LSI SAS1064 controller providing four ports of SAS connectivity to disk drives at bandwidths of 3Gb/sec. full duplex for each disk. Disks are NEBS Cer tified 146-GB, 10000-rpm SAS disks, 2.
Figure 7. Netra X4 200 s erver rear panel features Conne ctivit y Networking The Netra X4200 M2 server includes four on-board a uto-negotiating Giga bit Ethernet ports. These ports are all capable of providing simultaneous full bandwidth operation, wit h no shared bandwidth limitations.
USB Ports The Netra X4200 M2 server comes with two USB 2.0 ports. The two ports are located on t he right side of the rear of the pa nel. Telco Alarm Port A DB15 connector is provide Telco alarm acces s to the system. The telco alarm function and connector pinou ts are same as Netra 210/ Netra 240/ Netra 440/ Netra T2000 systems.
Reliability, Availability, and Serviceability (RAS) Reliability, availability, and serviceabilit y (RAS) a re aspects of a system’s design that a ffect its ability to operate continuously and to minimize the time necessary to service the system.
Operating Systems Netra X4200 M2 Se rver O peratin g Syste ms A world-class performanc e platform, the 64-bit Netra X4200 M2 server allow customers to run the operating system tha t best fits their needs.
Solaris 10 OS – The mo st a dvanc ed oper ating sy stem o n the planet Key Messaging In a class by itself, the Solaris Operating System is a significant leap forward form the Solari s 9 OS, establishing it i n a class by itself when compared to compet ing operating systems.
• Solaris Fault Manager proactively ha ndles system problems by removing components before failure. CPU, memory and I/O problems are diagnosed and corrected – before they can cause downtime.
Sun brings a complete systems approach to Linux: a value- added web s ervices stack for the entire system, hardware, OS, tools, and applicatio ns backed by Sun's global support infrastructure.
System Management Sun In tegrate d Light s-Out- Manager (ILO M) Sun Integrated L ights-out Manager is dri ven by an integrated system service processor that fol lows x86 standards and is different from SPARC(R ) technology- based system r emote management s olutions.
ILOM Wa tchd og Time r ILOM features a watchdog mechanism to detect and respond to system hang, should one ever occur. The ILOM watchdog is a timer that is continually reset by a user application as long as the ope rating system and user application are running.
Specifications Proces sor Opt ions Processor One or two Next- Generat ion AMD Opteron Processo r 2000 HE Series embedded class;Dual Core (2214 HE – 2.2 GHz) Cache 1 MB Level 2 Main Me mory 4 DIMM slots per CPU socke t, Registe red DDR2 /667 E CC DIM Ms (128 bit plus ECC datab us), total 8 DIMM slots.
supported languages Networking Softwar e ONC™, ONC+(T M), NFS(TM), WebNFS(TM ), TCP/I P, S unLink™, OSI, MHS, IPX™/ SPX, SMB technol ogies, and XML Manageme nt CLI (in-band and out-of-band), IPMI 2.0 (in-ba nd and out -of-band), SNMP (out-of-band only) Physical Specifications Description U.
Description AC Specificat ion DC Specificat ion Nominal Power Estimated 475 W Estimated 475 W Acous tic Nois e Emis sions These are the acoustic noise emissions of a Netra X4200 M2 server. Declared noise emissions are in accordance with IS O 9296 standards.
Ordering Information Stand ard Co nfigur ations – Pr econf igured Syste ms The Netra X4200 M2 server run the Solaris 10 Operating System on x64 as well as standard Linux distributions and Microsoft Windows Server 2003, Enterprise and St andard Editions.
Standard Configuration Part Numbers Part Number Standard Configuration Description N87-SFZ12H2GLAD Netra X4200 M2 Server, 1x AMD Opteron Model 2214 HE dua l core processor (2.
Power Cord Kits The Netra X4200 M2 server come s standard with two power supplies. A no-charge power cord kit option must be or dered for each AC power supply. Avai lable power cord kits include: Part Number Description X311L AC power cord U.S./Braz il.
Options The following options are supported by the Netra TM X4200 M2 s erver. Options that include an (X) in the part number indicate that the part can be ordered a s a field-installable part or for factory int egration.
Part Numbe r Optio n Descrip tion Maximum Number Supported Comm ents X4353A-Z Air Filter, 10-pack for 4 HDD version PCI-E Card s: Networ king Interfaces (X)7280A- 2 Dual port GigE UTP low- profile, R .
emb edded clas s processor. Sin gle pr oces sor system can also be expa nded with one additi onal hard disk driv e to a max. of two dri ves. 2. Th e en try- level singl e CPU standard confi gurat ion has only 2 memo ry slots that are usable; the o ther 4 mem ory s lots only w ork if a second CPU is ins talled.
Upgrades Upgrad e Path s Netra TM X4200 M2 servers are eligible for the Sun TM Upgrade Advant age Program (UAP). Through this program customers can trade-up their current Sun or non-Sun severs for a new Netra X4200 M2 server and receive a trade- in allowance t hat is applied as a percentage off of the list price on the new Netra X4200 M2 server.
How to Determine the Right Allowance Code Scenario: My customer has a Netra 1120 server and woul d like to upgrade to a Netra X4200 M2 server. What allowance pa rt number should I select? 1. From left hand column select the platform the customer has. 2.
Service and Support Warra nty The Netra TM X4200 M2 server f eatures a 1 year warranty. • Duration: 1 year, Next Business Day • HW coverage hours: Business hours • HW response times: Next busine.
More information is available at http://www.sun.com/service/support/sunspectrum . SunSpectrum service plan highlights include: • Integrated whole- system support • All the essentials for one great.
Warranty Upgrade to SunSpectrum Service The following table includes the part numbers and de scriptions for the warranty upgrades to SunSpectrum programs for the Netra X4200 M2 se rvers.
Wa rra nty Up gr ade to S un H W O nly Servi ce fo r Ne tra X4 200 M2 Part Numb er Descri ption W9D-N87- SD-1H Upgrade to 1 year Sun HW Only SBD for Netra X4200 M2 Server W9D-N87- SD-2H Upgrade to 2 y.
Glossary Chipkill A technology developed by IBM for s ituations that demand high availability. It allows a system (usually CPU or motherboard) to detect problems with the computer’s memory and selectively di sable the problematic DIMMS. ECC Error Correcting Code.
(MIBs) and return this data to the SNMP requesters. Hot-pluggable A feature that al lows an administrator to add or remove a device such as a disk drive without affecting hardware s ystem integrity. Hot-swappable A feature that al lows an administrator to remove and/or replace a device without affecting softwa re integrity.
Materials Abstract All materials w ill be available on SunWIN except where noted otherwise. Collateral Descripti on Purpose Distribution T oken # or COMAC Order # Product Literature Netra TM X4200.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Sun Microsystems X4200 M2 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Sun Microsystems X4200 M2 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Sun Microsystems X4200 M2, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Sun Microsystems X4200 M2 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Sun Microsystems X4200 M2, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Sun Microsystems X4200 M2.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Sun Microsystems X4200 M2. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Sun Microsystems X4200 M2 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.