– 1 – E01X23A41 Sony reserves the right to change products and specifications without prior notice. This information does not conv ey an y licens e by any implication or otherwise under any patents or other right. Application circuits shown, if an y , are typical e xamples illustr ating the operation of the de vices.
– 2 – ICX423AL USE RESTRICTION NO TICE (December 1, 2003 ver .) This USE RESTRICTION NO TICE ("Notice") is for customers who are considering or currently using the CCD products ("Products") set f or th in this specifications book.
– 3 – ICX423AL Block Dia gram and Pin Configuration (T op view) Horizontal Register Output Unit Note) Note) : Photo sensor GND V DD SUB RG H φ 1 V er tical Register HIS V OUT V φ 4 V φ 3 V φ 2 V φ 1 V L GND V GG V SS GND RD H φ 2 V L 7 9 10 11 12 13 14 15 16 17 18 19 20 6 5 4 3 2 1 Pin Description Pin No .
– 4 – ICX423AL Absolute Maximum Ratings Item HIS, V DD , RD , V OUT , V SS – GND HIS, V DD , RD , V OUT , V SS – SUB V er tical cloc k input pins – GND V er tical cloc k input pins – SUB S.
– 5 – ICX423AL DC Characteristics Output amplifier drain current Input current Input current Item I DD I IN1 I IN2 Symbol 6 Min. Unit Remarks T yp .
– 6 – ICX423AL Clock V oltage Conditions ∗ 1 The reset gate clock v oltage need not be adjusted when the reset gate clock is driv en when the specifications are as given belo w . In this case, the reset gate clock v oltage setting indicated on the back of the image sensor has not significance.
– 7 – ICX423AL Horizontal transfer c lock equiv alent circuit V ertical transfer cloc k equivalent circuit H φ 1 H φ 2 C φ H1 C φ H2 C φ HH R φ H R φ H V φ 1 C φ V12 V φ 2 V φ 4 V φ 3 .
– 8 – ICX423AL Drive Clock W avef orm Conditions (1) Readout cloc k waveform (2) V er tical transfer cloc k waveform V VH = (V VH1 + V VH2 )/2 V VL = (V VL3 + V VL4 )/2 V φ V = V VH n – V VL n .
– 9 – ICX423AL (3) Horizontal transfer c lock wa veform · Reset gate cloc k waveform (4) Substrate cloc k waveform 100% 90% 10% 0% V SUB tr tf twh φ M 2 φ M V φ SUB tr twh tf 90% 10% twl V φ H , V φ RG V HL , V RGL Clock Switc hing Characteristics Min.
– 10 – ICX423AL Image Sensor Characteristics (T a = 25°C) Item Sensitivity Saturation signal Smear Video signal shading Dark signal Dark signal shading Flick er Lag Symbol S Vsat Sm SH Vdt ∆ Vdt F Lag Min. 700 1000 Ty p . 1000 –130 Max. –120 25 2 1 5 0.
– 11 – ICX423AL Light Signal output 350mV Vlag (lag) FLD V1 Strobe light timing Output 1 10 1 500 VSm 350 3. Smear Set to standard imaging condition II . With the lens diaphragm at F5.6 to F8, adjust the luminous intensity to 500 times the intensity with av erage value of the signal output, 350mV .
– 12 – ICX423AL Drive Circuit 30V 15V XSUB –9V 5V XV1 XSG1 XV2 XV4 XSG2 XV3 –11V H2 H1 RG 6V 0.1 0.01 22/20V 3.3/25V 56k 27k 3.3/ 16V 270k 15k 15k 47k 3.3/35V 0.01 1000P 10k 15 15 22k 3.3/35V 2200P 1M V φ 4 V φ 3 V φ 2 V φ 1 SUB GND V L NC GND V DD HIS H φ 2 H φ 1 V L RG RD GND V SS V GG V OUT 3.
– 13 – ICX423AL Spectral Sensitivity Characteristics (includes lens characteristics, e xcludes light source character istics) Sensor Readout Clock Timing Chart 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 500 600 700 800 900 1000 400 W ave Length [nm] Relative Response Unit: µs Odd Field Even Field V1 V2 V3 V4 V1 V2 V3 V4 2.
– 14 – ICX423AL Drive Timing Chart (V er tical Sync) FLD VD BLK HD V1 V2 V3 V4 CCD OUT 620 625 1 2 3 4 5 15 20 310 320 335 330 340 581 582 13 5 24 6 135 246 582 581 2 1 4 3 6 5 10 315 325 2 1 4 3 .
– 15 – ICX423AL Drive Timing Chart (Horizontal Sync) 745 750 1 3 5 10 20 30 40 1 2 3 5 10 20 22 1 2 3 1 2 3 10 20 752 HD BLK H1 H2 RG V1 V2 V3 V4 SUB.
– 16 – ICX423AL Notes on Handling 1) Static charge prev ention CCD image sensors are easily damaged by static discharge . Before handling be sure to tak e the follo wing protective measures . a) Either handle bare handed or use non-chargeable glov es, clothes or material.
– 17 – ICX423AL Sony Corporation P acka ge Outline Unit: mm P A CKAGE MA TERIAL LEAD TREA TMENT LEAD MA TERIAL P A CKAGE MASS DRA WING NUMBER Ceramic GOLD PLA TING 5.90g 42 ALLO Y AS-A11(E) P ACKA GE STR UCTURE M 0.3 0.25 0.35 13.15 5.0 R3.0 6.0 2.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Sony ICX423AL c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Sony ICX423AL - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Sony ICX423AL, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Sony ICX423AL va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Sony ICX423AL, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Sony ICX423AL.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Sony ICX423AL. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Sony ICX423AL ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.