10,000 BTU Portable Air Conditioner Operating Instructions Model No. 6 G-PAC-10E2 .< V.121010.
Thank you for choosing a Sole us Air Powered by Gree Portable Air Conditioner. This owner’s man- ual will provide you with valuable information necessary for the proper care and maintenance of your new product.
LCDI POWER CORD AND PLUG This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side.
INCLUDE P ARTS INCLUDED Window Exhaust Adapter A S crew (7 ) Exhaust Hose Window Exhaust Adapter C Adjustable Window Slider (3) Ho se clip(2) Rubber plug Battery (AAA.1.5V) INCLUDE Window Exhaust Adapter B SUGGESTED TOOLS FOR WINDOW P ANEL INST ALLA TION 1.
1, Control panel and display l LJKW 2, Remo W e control signal receiver window 3, Handl H 4, Remote controller box 5, Air outlet 6, V ertical louvers 7, Horizontal louvers 8, Wheel 9, Air inlet 10, Gr.
SP ECIFICA TIONS x The cooling ca pacity is measured at an am bient temperature of DB 95 °F, WB 83 °F. x Noise level is measured at a distance of 3.28 ft away from the front of the unit, when the unit i s in cooling mode. x Power consumption is m easured when the fan runs at the highest s peed setting.
Attach the hooks to the back of air conditioner with the screws. hook screw Wind the power cord D round the power cord hooks. INSTALLATION OF THE POWER CORD HOOK .
P ARTS & WINDOW KIT ASSEMBL Y PARTS EXHAUST HOSE & ADAPTERS ASSEMBLY & INSTALLATION INSTALLATION When the unit is operating as an air conditioner or dehumidifier, the window kit a nd exhaust hose must be installed. When the unit is operating in fan mode, the window ki t and exhaust hose do not need to be installed .
SINGLE HOSE WINDOW KIT INSTALLATION When installing the exhaust hose, try and keep it as flat as possible. The less angles and bends in the hose, the better the unit will perform. If bending or an angle is necessary , use single 90 ° angles like the pictures above.
CONTROL P ANEL & DISPLA Y When pressing key is valid, buzzer makes a sound, indicated light indicates relevant state, system will last for 2 seconds. OPERATING INSTRUCTIONS l. 3. MODE Button 4. Fan 6 peed When the unit is running in Cool or F a n mode, press the Fan speed Button to select the fan speed in High, Middle, Low , Auto.
HOW TO USE THE REMOTE CONTROL For good receive, the distance between operator and the unit no more than 5 meters. Point t he remote control towards the units signal receiver window A . n o t t u b d e r i s e d e h t s s e r p d n a beep will sound when the unit re- ceives the signal.
1) Power On and Off - Press the ON/OFF (POWER) button once to manually turn the unit on. Press the Power button once more to turn t he unit off. When you m anually power the unit on and off by pressing the ON/OFF button, the preset timer will be cancelled.
5) Auto-on Timer: When the air conditioner is off, it can be set to autom atically turn on in 30 minutes to 24 hours at the previous set mode and fan setting. To set the Auto-on Tim er, press t he TIMER button on t he unit or remote control. Each touc h of the +/- buttons on the remote will change the timer setting in 30 minute increments (.
When the temperature or humidity is too high, the air conditioner may not be able to evaporate all of the water as quickly as needed. All moisture that is unable to be evaporated is p laced in a small bank up water tank in- side the unit.
MAINTENANCE Note: Make sure power is off and the power cord is not plugged into an electrical outlet prior to performing any maintenance on the unit. Clean or replace filter - If the air filter is blocked with a dust, the airflow volum e may reduce. It is recommended to clean the filter once every two weeks or as needed.
PROBLEM The Air Conditioner will not start POSSIBLE CAUSES The air conditioner is unplu gged or not connected well. The fuse is blown/circuit breaker is tripped.
PROBLEM The LCD Display is showing “E5” POSSIBLE CAUSES Low Voltage Protection SOLUTIONS x Unplug for 10 minutes and then turn on the unit. If “E5” is still dis- played, contact customer service.
W ARRANTY One Year Limited Warranty Soleus International Inc. warrants the accompanying Soleus Air Powered by Gree Portable Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) y ear from the date of original retail purchase in the United States.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Soleus Air SG-PAC-10E2 (KY-101) c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Soleus Air SG-PAC-10E2 (KY-101) - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Soleus Air SG-PAC-10E2 (KY-101), vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Soleus Air SG-PAC-10E2 (KY-101) va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Soleus Air SG-PAC-10E2 (KY-101), mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Soleus Air SG-PAC-10E2 (KY-101).
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Soleus Air SG-PAC-10E2 (KY-101). Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Soleus Air SG-PAC-10E2 (KY-101) ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.