Installation Guide



This installation guide provides instructions for installing the AXIS 262+ Network Video Recorder on your network. For all other aspects of using the product, please see the User’s Manual, available on the CD included in this package, or from www.axis.com/techsup

Front panel

Power indicator Network indicator Status indicator Disk indicator
Serial number Power button

Power connector 9-pin I/O terminal
connector Factory setup button
adapter RS-232 connector · connector Network

To make it accessible on the network, the AXIS 262+ must be assigned an IP address. The recommended method for setting IP addresses in Windows is AXIS IP Utility. This application is free and available on the Axis Network Video Product CD supplied with this product.
AXIS IP Utility automatically discovers and displays Axis devices on your network. The application can also be used to manually set a static IP address.

Automatic discovery 1. Check that the AXIS 262+ is connected to the network and that power has been applied. 2. Start AXIS IP Utility. 3. When the video recorder appears in the window, double-click it to open its home page. 4. See page 7 for instructions on how to set the password.
Set the IP address manually 1. Acquire an unused IP address on the same network segment your computer is connected to.


When accessing the AXIS 262+ for the first time, the ‘Configure Root Password’ dialog will be displayed.


The Main View page of the AXIS 262+ is displayed, with links to the Setup tools which allow you to customize the video recorder.
Setup - Provides all the tools for config- uring the video recorder to requirements.
Help - Displays online help on all aspects of using the video recorder.


Once installed, your AXIS 262+ is accessible on your local network (LAN). To access the Video Recorder from the Internet, network routers must be configured to allow incoming traffic, which is usually done on a specific port. Refer to the documentation for your router for further instructions. For more information on this and other topics, visit the Axis Support Web at www.axis.com/techsup
If you are experiencing problems accessing the AXIS 262+ from the Internet refer to the NAT traversal section of the AXIS 262+ User’s manual

RS-232 connector - For the connection of a UPS (Uninterruptible Power Supply) unit. For approved models, see the AXIS 262+ User’s Manual.
Network connector- RJ-45 Ethernet connector. Using shielded cables is recommended.
I/O terminal connector - The 9-pin I/O terminal connector provides the interface to four digital outputs, four digital photo-coupled inputs and Ground.



The indicator LEDs are tested during startup. The Status, Network and Disk LEDs show red for 1 second, and the Power LED shows amber for 1 second

This will reset all parameters, including the IP address, to the Factory Default settings and format the hard disk drive:
1. Press the Factory Setup button on the rear of the unit for 20 seconds while the unit is powered up. 2. When the Status indicator on the front panel displays steady green, which can take up to 3 minutes, the AXIS 262+ has been reset to the factory default settings. 3. Re-assign the IP address, using one of the methods described in this document. It is also possible to reset parameters to the original factory default settings via the Web interface. For more information, see the online help or the user’s manual.
Resetting the AXIS 262+ to the factory default settings will also erase all recorded video. If you have recorded video you wish to save, download it from the download tab on the Main View page, before resetting the unit.
The user’s manual is available from the Axis Web site at www.axis.com or from the Axis Network Video Product CD supplied with this product.
Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.
Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.
Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.