Manuel d'utilisation / d'entretien du produit IZS31 du fabricant Sierra Monitor Corporation
Aller à la page of 26
Doc. No.IZ*-OMK0015 - B OPERA TION MANUAL PRODUCT NAME : Ionizer MODEL: IZS31 Series ○ Read this operation manual carefully to understand before inst allation and operation. ○ Pay extra attention on the clause concerning the safety . ○ Keep this operation manua l available whenever necessar y .
1 INDEX 1.Sefety instructions ・ ・ ・ ・ ・・・・・・・ ・ ・・・・・・・・・・ ・・・・・ ・・ ・ ・・・ ・ 2 2.Installation ・・・・・・・・・・・・・・・ ・・ ・・・・・・・・ ・ ・ ・ ・ ・・ ・・ ・ ・ ・・・ 6 2-1.
2 1. Safety instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard by labeling "Caution" , "W arning" , and "Danger" .
3 WARNING 1. This product is intended to be used for the general F A devices. If other applications (especially the ones indicated in 4 on page 2) are used, please contact SMC before the use. 2. Use under specified vo ltage and temperature. Voltage out of specific ation may cause malfunction, break age, electric shock and fire.
4 5. Do not touch electrode needle with finger or metal tool directly. It may cause injury. If electrode needle or cartridge is it ma y stick to the fingers, damaged by tools, it will not on ly interf ere the specification function and performance but also may cause operation failure or accident.
5 9. Be sure there is no incorrect wiring before oper ation. Incorrect wiring ma y cause product breakage or malfunction. 10. Flush pneumatic pipi ng before its installation. Make sure that all dust, water droplet, oil etc. are eliminated before piping.
6 accident. 3. Do not open the case to disa ssemble and reconstruct the product. It may cause electric shock, operation failure and disast er such as fire. In addition, note the product, which is disassembled or reconstructed, may not satisfy the functions and per formance in the sp ecifications and is out of guarantee.
7 3. Mount intermediate brackets on the ionizer body at regular interval. 4. Tap M5 thread on the brackets m ounting positions at the installation side, and fix the ionizer body and brackets with M5 threads. 5. Adjust angle of the ionizer body to ensure prope r static charge eliminat ion, and fix it with detent threads (M5) of brackets.
8 6. Be sure to ground the DC1 (-) lead wire [blue] of the power supply cable (R esistance between the lead wire and the earth ground should be 100 Ω or less.) If the lead wire is not gr ounded, the ion balance will be unstable, and an electric shock may occur .
9 Auto balance sensor Horizontally place the aut o balance sensor under the ionizer and face its metal plate upward. Because the ion balance will be changed depending on the installati on height, install the sensor on the same le vel with a workpiece as much as po ssible.
1 0 2. Connect the lead wires in acco rdance with the lead wire list. (See Chapter 4) Arrange lead wires in a ccordance with the wiring table. The unused wires should be cut short or covered with vinyl tape without pealing the coat to prevent them from coming contact with other wires.
11 3. DC mode Plasma ions or minus ions are continuously discharged. The parts ot her than the charged object need to be grounded to prevent them from being charged.
1 2 4. Selection and setting of equipment 4- 1. Sensing DC mode 1. Selection of bar length ・ Select the length applicable to work size base on static charge elimination area and st atic charge elimination characteristics. 2. Installation of body ・ Keep the distance between the ioni zer and charged objects within 200 to 2000mm.
1 3 6. Wiring of the power supply cable ・ Connect dedicated pow er supply cables. Connection with the power supply for ionizer opera t ion Symbol Cable color Cable name Connection Description DC.
1 4 8. LED display POWER LED ・・・ The power supply input and the connection of the sens ors are displayed. LED name Functions MAIN Lights up when the power supply is applied. (Green) (Flashes when wrong po wer supply is applied. ) POWER SNSR Lights up when the feed back sensor is connected.
1 5 9. Alarm T ype of alarm Description How to reset Abnormal high voltage Notifies when overcurrent such as high voltage leakage occurs. The ion-discharge-outp ut is stopped, HV ALRM sets off and output the signal for failure. T urn of f the power supply to solve the problem.
1 6 4-2. Pulse DC mode 1. Selection of the bar length ・ Select an appropriate length that is suitable for the work size, static charge elimination characteristics and static charge elimination range. 2. Installation of the ionizer ・ Keep the distance between the ionizer and charged object within 50 to 2000mm.
1 7 5. Setting of the frequency selecting switch ・ Select the ion-production frequency . Ion-production frequency Switch setting 1Hz 0 3Hz 1 5Hz 2 10H z 3 15Hz 4 20Hz 5 30Hz 6 60Hz 7 6. Wiring of the pow er supply cables ・ Connect a dedicated power supply cable.
1 8 8. LED display POWER LED ・・・ The power supply input and the connecti on of the sensors are displayed. LED name Functions MAIN Lights up when the power supply is applied. (Green) (Flashes when wrong po wer supply is applied. ) POWER SNSR Lights up when the auto balance sensor is connected.
1 9 9. Alarm T ype of alarm Description How to reset Abnormal high voltage Notifies when overcurr ent such as high voltage leakage occurs.T he ion-discharge-outp ut is stopped, HV ALRM sets off and output the signal for failure. T urn off the power supply to solve the problem.
2 0 4-3 . DC mode 1. Selection of bar length ・ Select the length applicable to work size base on static charge elimination area and st atic charge elimination characteristics. 2. Installation of body ・ Keep the distance between the ioni zer and charged objects within 50 to 2000mm.
21 6. LED display POWER LED ・・・ The power supply input and the connection of the sens ors are displayed. LED name Functions MAIN Lights up when the power supply is applied. (Green) (Flashes when wrong po wer supply is applied. ) POWER SNSR Goes out.
2 2 4-4. Power supply cable connection circuit ■ NPN Note) Because the s ensor monitor output ( OUT4 : Dark Green ) is not insulated from the internal circuit of the ionizer, It is ground ed.
2 3 ■ PNP Note) Because the sensor monitor output ( OUT4 : Dark Green ) is not insulated from the internal circuit of the ionizer, It is ground ed.
2 4 5. Specifications 5-1 . Ionizer Ionizer model IZS31(NPN) IZS31P(PNP) Type Corona discharge Voltage supply method Sensing DC , pulse DC, Plus DC, Minus DC Discharge output +/- 7000 V Ion balance *1 +/-30V (For Stainless electrode needle, from -10 0 to +100V) Fluid Air (Clean dry air) Op.
2 5 5-2 . Sensor Sensor model IZS31-DF (Feed back sensor) IZS31-DG (Auto-balance sensor) Operating ambient temp 0 to 50 ℃ Operating ambient humidity 35 to 80%Rh(No dew condensation) Case m.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Sierra Monitor Corporation IZS31 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Sierra Monitor Corporation IZS31 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Sierra Monitor Corporation IZS31, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Sierra Monitor Corporation IZS31 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Sierra Monitor Corporation IZS31, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Sierra Monitor Corporation IZS31.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Sierra Monitor Corporation IZS31. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Sierra Monitor Corporation IZS31 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.