Manuel d'utilisation / d'entretien du produit 700 du fabricant Siemens
Aller à la page of 36
1 Pure 700, Pure 500 User Guide.
2.
1 Dear Customer , Congratulations! Y ou ha ve selected the new Pure hea- ring instruments from Siemens. These instructions as well as the guidance from y our Hearing Care Professional will help y ou understand how your new Pure hearing instruments work.
A 1 2 Contents 3 4 5 6 7 8 9 10 11 Y our Pure hearing instrument 6 Intended use 7 General notes on safety 8 Handling of standard and rechargeable batteries 10 Low battery indicator 1 - 0 Inserting the.
A 1 16 14 15 2 Handling of the Receiver Unit 23 Remove Receiver Unit 2 - 3 Attach Receiver Unit 2 - 3 Accessories 24 Remote contr ol 2 - 4 Charger 2 - 5 Tek wireless enhancement 2 - 6 T roubleshoo tin.
Features: 1 Receiver Unit 2 Dome 3 Batter y com partment 4 Push Button 5 Microphone Co ver 6 Receiver Mold 7 C-Guard 2 7 1 2 3 4 Y our Hearing Care Professional offers an assor tment of re- ceiver lengths and Dome sizes to best fit your ear . C AUTION Risk of injur y caused by incorrect use of Domes.
Hearing instruments are intended to impr ove the hearing of hearing impaired persons. Diagnosis and prescription of a hearing instrument must be performed by hearing health specialists, e.g. ENT doctors, audiologists or acou- sticians. Read and follo w the instructions of this user guide to av oid injuries or damage to the hearing instrument.
NOTICE Y our hearing instrument is sensitive to extreme heat, high humidity , strong magnetic fields (> 0.1T), X-rays and mechanical stress. Do not expose y our hearing instrument to extreme X temperature or high humidity . Do not lea ve it in direct sunlight.
W ARNING Risk in explosive envir onments, e.g. mining areas! Don't use your hearing instruments (and remo te con- X trol) in areas where there is a danger of explosions. NOTICE f or batteries Leaking batteries damage the instrument. Remove batteries when the instrument is no t in use for X a prolonged period of time.
Remove the tab on your X batteries only when you are ready to use them. The positive (+) side of the batteries is always the X smooth side. Always keep spare batteries with y ou.
Handling of standard and rechargeable batteries Inserting the batter y Open the batter y compartment completely X using your fingernail as shown in the illus- tration. Insert the proper size batter y so that X the "+" symbol on the batter y aligns with the "+" marked on the batter y compartment.
Handling of standard and rechargeable batteries Removing the battery Open the batter y compartment complete- X ly . Normally the batter y drops out when the X compartment is completely open. If the batter y does not come out, lightly tap the instrument or push the batter y out with a pencil as shown.
Inserting and removing your hearing instrument 7 NOTICE Do not use lubricant when y ou insert the Dome/ ear- X mold, because it may clog the sound outlet.
Removing y our hearing instrument T urn your hearing instrument off. X Hold the Receiver Unit/ Receiver Mold X between your thumb and index finger and carefully pull it out. Y ou may find it helpful t o lightly push your ear fr om the back. C AUTION The ear tip needs to be attached pr operly.
T urn on: Press the push button f or 2 seconds to turn the X instrument ON. T urn off: Press the push button f or 2 seconds to turn the X instrument OFF . Power-on dela y Y our hearing instrument is equipped with a „power-on-de- lay“ feature which can be activated b y your Hearing Care Professional.
9 Changing the hearing program Y our hearing instruments offer up to 5 hearing pro- grams for specific listening en vironments. Each time you press the pr ogram button, your hea- ring instruments switch to the next pr ogram, confir- ming each change with an acoustic signal.
Y our hearing instruments are equipped with e2e (ear-to- ear) wireless 2.0 technology . Advantages of the wireless functionality: Automatically adjusts bo th hearing instruments simulta- neously to different listening situations. Allows use of accessories, e.
NOTICE Do not put the hearing instruments in X water . Y our hearing instruments are highly sensitive systems. Proper care and handling will ensure the best possible performance. Clean instruments regularly to prevent damage t o the X hearing instruments and to av oid health problems.
Y our hearing instrument has either a Dome or a Receiver Mold. C-Guard Domes and Receiver Molds include integrated C-Guard wax pro tection system. Domes and Receiver Molds 12 Full functionality of Domes and Receiver Molds is only assured with a working C-Guard.
Daily cleaning Cerumen (ear wax) on the C-Guard affects sound quality . Remove wax with a soft tissue. X No other tools are req uired. The Dome/ Receiver Mold cleans best right after taking the hearing instru- ments off. This way Cerumen can not dry and harden.
Replacing the Dome Holding the Receiver Unit in one hand, grasp the X Dome between the thumb and index finger of your o ther hand. Then remove the Dome fr om the receiver . X The new Dome is delivered in a box. Leave the Dome in the bo x and press the tip X of the Receiver Unit into the new Dome as shown in the picture.
Replacing the C-Guard of the Receiver Mold Remove the C-Guard with the bac k side of X the C-Guard tool. The C-Guard can no t be re-used after the disassembling process. Insert the new C-Guard. X Change the C-Guard appro ximately ever y X three months, or as needed.
turn remove join turn Handling of the Receiver Unit 13 Remove Receiver Unit Hold the instrument in one hand and turn the Receiver X Unit with the other hand carefully t o the left (45º) and remove it. The Receiver Unit can be changed as needed by y our Hearing Care Professional.
In the event your hearing instruments can be X controlled b y another person's remote contr ol, re- turn hearing instruments and remote contr ol to your Hearing Care Professional.
14 Accessories Charger Y our hearing instruments work with standard or rechar- geable batteries. With the easy-to-use char ger you can charge the rechar geable batteries for one or two hearing instruments. After just five hour s of charging, the char ger shuts itself off and the hea- ring instruments are ready to run f or a day .
14 Accessories Tek wireless enhancement Y our hearing instruments together with the Tek Connect remote contr ol will allow you to connect y our hearing instruments to the gro wing world of technology . V ia a special Bluetoo th connection it is possible to receive audio signals from y our mobile, your television or your mp3-pla yer .
27.
Y our Pure hearing instruments are reliable devices. Should a problem occur , it can usually be corrected quic kly . Use these troubleshoo ting tips to resolve sim ple issues.
If you still encounter pr oblems after tr ying these sugge- stions, consult your Hearing Care Pr ofessional. Possible Solution Insert new st andard batter y Clean Receiver Mold / clean or change Dome .
Operating frequencies: F c =3.28 MHz This Class B digital apparatus complies with Canadian ICES- 003. Changes or modifications not expressly appr oved by the party responsible for compliance could void the users aut- hority to operate the equipment.
This equipment has been tested and f ound to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to pr ovide reasonable pro tection against harmful inter ference in a re- sidential installation.
Within the European Union, the marked eq uip- ment is covered b y "Directive 2002/96/EC of the European Parliament and of the Council of 27 Januar y 2003 on waste electrical and elec- tronical equipment". Amended by "Directive 2003/108/EC" (WEEE).
Hearing instrument LEFT RIGHT Model Serial number 312 Batter y 312 yes no Power on dela y yes no yes no Push button yes no Signal tones on off Low battery warning on off on off Volume control limit on off on off V olume control change on off Hearing program Description of the hearing program 1 2 3 4 5 Remote control (e.
Notes 34.
.
www .siemens.com /hearing Siemens Audiologische Technik GmbH Gebbertstrasse 125 91058 Erlangen Germany Phone +49 9131 308 0 © Siemens AG, 02.2008 · SB Document No.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Siemens 700 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Siemens 700 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Siemens 700, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Siemens 700 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Siemens 700, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Siemens 700.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Siemens 700. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Siemens 700 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.