The air purifier draws in room air from the air intake, passes the air through a Pre-Fil- ter, a Washable Deodorizing Filter and a HEPA Filter inside of the unit, then discharg- es the air through the air outlet. The HEPA Filter can remove 99.97% of dust particles as small as 0.3 microns that pass through the filter and also helps absorb odours. The Washable Deodorizing Filter gradually absorbs odours as they pass through the filter.
Some odours absorbed by the filters may break down over time, resulting in additional odour. Depending on the usage environment, especially when the product is used in extreme environments (significantly more severe than normal household use), this odour may become strong in a shorter period than expected. If the odour persists, the filters should be replaced.

(Common illustration has used “KC-850E”.)

FEATURES CONTENTS
Unique Combination of Air Treatment Technologies Triple Filtration System + Plasmacluster + Humidification
TRAPS DUST* Washable pre-filter traps dust and other large airborne particles. DECREASES ODOURS Washable deodorizing filter absorbs many common household odours.
REDUCES POLLEN & MOLD* HEPA filter traps 99.97% of particles as small as 0.3 microns.
FRESHENS Plasmacluster treats the air similar to the way nature cleans the environment by emitting a balance of positive and negative ions.
HUMIDIFIES Runs up to 10 hours per filling.**
*When air is drawn through the filter sys- tem.
**Room size: up to 48 m2 (KC-860E) up to 38 m2 (KC-850E) up to 26 m2 (KC-840E)
Sensor Technology continuously monitors air quality, and automatically adjusting op- eration based on detected air purity and humidity.
Thank you for purchasing this SHARP Air Purifier. Please read this manual carefully before using the air purifier. After reading, keep the manual in a conven- ient location for future reference.

When using electrical appliances, basic safety precautions should be followed, including the following:
If this air purifier should cause interference to radio or television reception, try to correct the interfer- ence by one or more of the following measures:

tended period of time in the same location, periodically clean the wall and protect the wall with a vinyl sheet, etc. to prevent the wall from becoming dirty.




KC-840E
BACK
Handle (2 locations left and right)


Indicates condition and humidity of room air.
Indicates the room condition of odour, dust, and humidity.
ODOUR MONITOR
The dust sensor continuously monitors the air and changes colour depending on air purity.KC-860E has 5 levels of dust detector.
The odour sensor continuously monitors the air and changes colour depending on odour intensity.
odour intensity.

Odour in the room
G
When the dust sensor detects dust, the fl ashing light moves depending on dustiness.
(Ex.) At 60 % humidily
Plasmacluster Indicator Light (blue) Blue: Plasmacluster ON Light off: Plasmacluster OFF
80 % or more
Less than 30 %

The dust sensor continuously monitors the air and changes colour depending on air purity.
High – 65 % or more Med – 65 % or less of 40 % or more Low – 40 % or less
G
Water Supply Indicator Light(red) This light will illuminate when the water tank needs to be refi lled.
G
G
G
G
G
G
When the dust sensor detects dust, the fl ashing light moves depending on dustiness. Plasmacluster Indicator Light (blue) Blue: Plasmacluster ON Light off: Plasmacluster OFF

FILTER INSTALLATION
To maintain the quality of the filters, they are packed in plastic bags and placed in the unit. Be sure to remove the filters from the plastic bags and replace the filters in the unit before initial use.
Install the filters
1 Install the HEPA Filter.
1 Remove the Back Panel.
Gently push down on the tabs, then tilt and remove the back panel.
Please make sure that the HEPA Filter is placed in proper orientation.
Installing the filter backwards will affect the performance of the unit.

Tabs on the top

(left and right) into the small holes in the unit, and slide the Washable Deodor- izing Filter between the HEPA Filter and the Back Panel.
2 R e m o v e t h e Wa s h -

able Deodorizing Filter (black) and HEPA Filter (white) from the plastic bags.
per tabs (left and right) to lock in place.

date on the Date Label.

Use the usage start date as a guide for when the filters should be replaced.

The unit can be used in the Clean Air Mode without putting water in the Water Tank. When using the Clean Air & Humidify Mode, or the CLEAN ION SHOWER Mode, the Water Tank should be filled with water. 1 Remove the Water Tank by unlatching the
top.
fill the Water Tank with tap water.
3 After filling, securely tighten the Tank Cap.
4 Replace the Water Tank in the unit.


Press any of the buttons to se- lect mode and start the unit.
Use the Clean Air & Humidify Mode to quickly clean the air, reduce odours and to humidify.
2 Press the CLEAN AIR & HUMIDIFY MODE Button.
sired fan speed.
Press the Power OFF Button to turn the unit off.
About Automatic Humidify Mode The Temperature/Humidity sensors automatically detect and adjust humidity according to changes in room temperature. Depending on the size and humidity of the room, humidity may not reach 55~65 %. In such cases, it is recommended that CLEAN AIR & HUMIDIFY/MAX MODE be used.
Temperature Humidity ~18 ºC 65 % 18 ºC~24 ºC 60 % 24 ºC~ 55 %

Use the Clean Air Mode when additional humidity is not required.
1 Press the CLEAN AIR MODE Button on the display.
sired fan speed. • Indicator lights will show the fan speed currently selected.
Press the Power OFF Button to turn the unit off.
CLEAN ION SHOWER Mode with humidification releases high-density Plasmacluster ions. By continuously discharging strong airflow for 15 minitues, the unit effectively removes air-
borne dust, pollen, mold and allergens from the air as they are drawn through the filter system. Water must be in the Water Tank when this mode is selected. The unit humidifies when there’s water in the Water Tank, and it operates without humidifying
when there’s no water in it.
on the display to select this mode. When the operation finishes, the unit will return to the prior operation.
Press the Power OFF Button to turn the unit off.
Fan Speed Button Please note the fan speed cannot be adjusted during the CLEAN ION SHOWER MODE.

*HiGH fan speed is an intermediate speed between MEDIUM and MAX.

Plasmacluster ON/OFF Button Press the Plasmacluster ON/OFF Button to turn Plasmaclus- ter Ion Mode ON and OFF. When Plasmacluster is ON, both the Indicator Light and Plasmacluster Indicator Light turn on.
Use when the light on the front panel is too bright.
Refer to the diagram on the right to select the desired brightness on the front panel.
The lights on the front panel are brighter.
The lights on the front panel are brighter.
The lights on the front panel are darker.
The lights on the front panel are darker.
The lights on the front monitor turn off
The lights on the front monitor turn off.
When the Water Tank is empty, the Water Supply Indicator Light will fl ash to indicate that the Water Tank should be refi lled. Please note the light will not fl ash even when the Water Tank is empty during the Clean Air Mode and the Clean ION SHOWER Mode. Sound indicator setting for water supply. In addition to the Indicator Light, the unit can be set to signal with an audible beep when the Water Tank is empty. With the unit OFF, press the Lights Control button for 3 seconds to turn the audible signal ON.
Cancellation To cancel the audible signal, with the unit OFF, press the Lights Control button again more than 3 seconds.
Set to “low” if the DUST MONITOR and ODOUR MONITOR is constantly red to reduce sensitivity, and set to “high’ if the DUST MONITOR and ODOUR MONITOR is constantly green to increase sensitivity.
1 With the unit OFF, press the Fan Speed Button for 3 seconds.
The Fan Speed Indicator Lights will display the currently set sensor sensitivity level. The factory setting is Standard, indicated by the MED light. 2 Press the Fan Speed Button to set the desired sensor sensitivity.
Refer to the diagram on the right to select the desired sensor sen- sitivity level. 3 Press the Power OFF Button.
Fan Speed Indicator Light

To maintain optimum performance of this air purifier, please clean the unit including the sensor and filters periodically. When cleaning the unit, be sure to first unplug the power cord, and never handle the plug with wet hands. Electrical shock and/or bodily injury may occur as a result.
Care Cycle After 720 hours of use (30days × 24hours = 720)
The Filter Indicator Light will illuminate as a reminder to perform maintenance of the Back Panel, Sensors, and Humidifying Filter. The Indicator Light will turn on after approximately 720 hours of use.
After performing maintenance, reset the Filter Indicator. Plug the unit in, turn power ON, and press the RESET button for 3 seconds. The Filter Indicator Light will go off. Even if the Filter Indicator Light is already off, the RESET but- ton should be pressed to reset the maintenance timer.

Care Cycle Whenever dust accumulates on the unit or every 2 months Gently remove dust from the sensor opening and the back panel, using a vacuum cleaner attachment or similar tool. When the back panel has stubborn dirt 1 In case of oily dirt, soak the back panel in water with
kitchen detergent. Avoid scrubbing the back panel hard when washing. 2 Rinse the back panel repeatedly with clean water to re-
move the solution residue. 3 Drip dry filter to remove excess water.
SENSOR FILTER CARE Remove the sensor filter and tap it lightly over a sink or bin to dislodge dust. If it is very dirty, wash it gently with lukewarm water. Do not use any detergents or chemicals of any kind to clean the filter. Dry the filter completely before replacing in the unit. Do not operate unit without all filters properly installed.
To prevent dirt or stains on the unit, clean regularly. If stains are allowed to remain, they may become difficult to remove. Wipe with a dry, soft cloth For stubborn stains or dirt, use a soft cloth dampened with warm water. Do not use volatile fluids Benzene, paint thinner, polishing powder, may damage the surface. Do not use detergents Detergent ingredients may damage the unit.

WATER TANK
Rinse the inside of the tank by leaving a small amount of luke- warm water inside, closing the tank cap firmly, and shaking the tank. Mild household detergents may be used to clean the inside of the tank, but detergent should be diluted and the tank should be thoroughly rinsed to remove all detergent residue. (Note the Water Tank is not dishwasher safe.) TANK CAP CARE care cycle... once a month The small cap back of the tank cap is removable. When the tank cap and small cap are dirty and slimy, cleaning is necessary. Use a cotton swab or a toothbrush.
When an unpleasant odour is noticed from the air outlet. When performance of filter seems to be reduced and odours persist.
1 Rinse dirt from the WASHABLE DEODORIZING
FILTER under lukewarm water. Remove dust on the washable deodorizing filter before washing.
2 Drip dry filter to remove excess water.
possible, dry outdoors. Dry filter in a sideways position to avoid warping of the filter. The filter takes about 6 hours to dry out.
Dry filter completely before replacing to prevent odours. Do not operate unit without all filters properly installed.

Frequency of maintenance cycle will depend on the hardness of the water. Avoid spilling water when removing or cleaning the tray. 1 Remove the Water Tank and Humidifying
When Water Deposits are Difficult to Remove
Tray.
Unlatch the Water Tank first, then re- move the tray. Use both hands when pulling out the Hu- midifying Tray to avoid spilling water.
way with lukewarm water, add a small amount of mild kitchen detergent, and leave to soak for about 30 min- utes.
Dilute detergent according to instructions on the container. Clean difficult-to-reach parts with a cotton swab or tooth brush.
Humidifying Tray. Drain accumulated wa- ter by tilting the Humidifying Tray slowly.
Do not hold this part.
Tray with lukewarm wa- ter.
Tray with lukewarm water to remove impurities.
place the Humidifying Tray in the unit.
The Humidifying Filter will not
fit if placed in backwards. Be sure there is no gap between the Humidifying tray and the unit when the Humidifying Tray is replaced in the unit. The unit may not operate properly if the Humidifying Tray is not prop- erly replaced in the unit.
If the Styrofoam float comes off, replace by inserting the tabs of the Float into the holes in the Humidifying Tray as shown in the diagram.
Insert the float below this tab.
Insert the tab on the other side of the float into the hole. Insert the tab of the float into the hole.

HUMIDIFYING FILTER
Care Cycle Once a month or when the Filter Indicator Light is on.
Frequency of maintenance cycle will depend on the hardness or the impurities of the water that you use; the harder the water the more often descaling will be necessary. Pay attention not to spill water when cleaning the filter. 1 Remove the Water Tank and
Humidifying Tray.
peatedly with lukewarm water to remove all the solution resi- due. Inadequate rinsing may cause odour and affect the performance and/or appear- ance of the unit. * Do not scrub the Humidi- fying Filter, rinse gently under lukewarm water only.
2 Remove the Humidifying Filter
from the Humidifying Tray. Avoid spilling water from the Humidifying Tray. 3 Preparing the descaling solu-
tion. Citric acid, available at some drugstores, or 100 % bottled lemon juice are used for descaling. Choose either one to use, and prepare the descaling solution. <For using citric acid> Dissolve 3 teaspoons of citric acid and 2 1/2 cups of lukewarm water in a suitable container, and stir well. <For using lemon juice> 100 % bottled lemon juice can be used for descaling. Use only 100 % bottled lemon juice with no pulp (strain juice if necessary). Combine 1/4 cup lemon juice and 3 cups of lukewarm water in a con- tainer large enough to hold the Humidify- ing Filter and stir well.
ON, and press the Filter Reset Button on the display for more than 3 seconds to reset.
You may notice reddish-brown or white deposits forming on the surface of the Humidifying Filter. These impurities (cal- cium, etc.) are due to the impurities con- tained in tap water; this is not a defect. Replace the Humidifying Filter when it is covered completely in white deposits.
Pre-soak the Humidifying Filter in the solution for 30 minutes before cleaning.
When using lemon juice, it is recommended to pre- soak longer than citric acid.

Filter life will vary depending on the room environment, usage, and location of the unit. If dust or odours persist, replace the filters. (Refer to “Please read before operating your new Air Purifier”)
HEPA Filter Up to 5 years after opening
Filter life can be greatly reduced depending on the room environment. Cigarette smoke, pet dander, and other airborne particles can reduce filter life. Check filters regularly and replace as necessary.
The filter can be repeatedly used after washing, or it can be replaced.
Humidifying Filter Up to 2 years after opening

Before calling for service, please review the Troubleshooting chart below, since the problem may not be a unit malfunction.
SYMPTOM REMEDY (not a malfunction)
Odours and smoke are not removed.
The Front Monitor illuminates green even when the air is impure.
The Front Monitor illuminates orange or red even when the air is clean.
A clicking or ticking sound is heard from the unit.
The discharged air has an odour.
The unit does not operate when cigarette smoke is in the air.
Filter Indicator Light is illuminated.
The Front Monitor are turned off.
The Water Supply Indicator Light does not illuminate when the tank is empty.
Water lever in the tank does not decrease or decreases slowly.
The Front Monitor lights change colour frequently.

ERROR DISPLAY KC-850E•KC-860E If error occurs again, contact the Sharp Service Centre.

Abnormal humidity filter Verify if the Humidifying Filter, Humidifying Tray and Water Tank are properly installed and then turn power ON again.
Flashing of the Clean Air & Humidify Indicator Light.
Abnormal fan motor Turn power OFF to cancel the error display, wait one minute, and then turn power ON.
Flashing of the Fan Speed Indicator Light ' '.
Unplug the unit, wait one minute, and plug the unit in again.
Flashing of the Fan Speed In- dicator Light ' '.
Flashing of the Fan Speed In- dicator Light ' '.

Abnormal humidity filter Verify if the Humidifying Filter, Humidifying Tray and Water Tank are properly installed and then turn power ON again.
Flashing of the Clean Air & Humidify Indicator Light.
Abnormal fan motor Turn power OFF to cancel the error display, wait one minute, and then turn power ON.
Flashing of the Fan Speed Indicator Light ' '.
Unplug the unit, wait one minute, and plug the unit in again.
Flashing of the Humidity Indi- cator Light ‘High’ or ‘Low’.
Flashing of the Fan Speed In- dicator Light ' '.
Flashing of the Fan Speed In- dicator Light ' '.


Fan Speed (m3/hour) 396 240 84 306 168 60 210 132 48
Rated Power (W) 56 19 5.5 (4.9) 41 11.6 3.8 (3.3) 26 9.5 3.7 (3.4)
Noise Level (dBA) 51 39 17 47 35 15 45 34 15
Fan Speed (m3/hour) 396 240 120 288 168 84 186 132 54
Rated Power (W) 56 21 8.8 (8.2) 40 13.5 6.8 (6.3) 21 11.5 6.1 (5.8)
Noise Level (dBA) 50 39 25 47 35 22 42 34 20
Humidification (mL/hour)*2 730 500 300 600 400 230 450 330 170
Dimensions (mm) 398 (W) × 288 (D) × 627 (H) 378 (W) × 265 (D) × 586 (H) 360 (W) × 233 (D) × 550 (H)
Fan Speed Adjustment MAX MED LOW MAX MED LOW MAX MED LOW
Recommended Room Size (m2)*1 ~48 ~38 ~26
Filter type Dust collection HEPA with Microbial control *3

In order to operate the electrical circuits while the power plug is inserted in the wall outlet, this
Humidification Amount decreases as temperatures decrease or humidity rises.
For energy conservation, unplug the power cord when the unit is not in use.

A. Information on Disposal for Users (private households)
Used electrical and electronic equipment must be treated separately and in accordance with legislation that requires proper treatment, recovery and recycling of used electrical and electronic equipment. Following the implementation by member states, private households within the EU states may return their used electrical and electronic equipment to designated collection facilities free of charge*. In some countries* your local retailer may also take back your old product free of charge if you purchase a similar new one. *) Please contact your local authority for further details.
If your used electrical or electronic equipment has batteries or accumulators, please dispose of these separately beforehand according to local requirements.
By disposing of this product correctly you will help ensure that the waste undergoes the necessary treatment, recovery and recycling and thus prevent potential negative effects on the environment and human health which could otherwise arise due to inappropriate waste handling.
If you wish to discard this product, please contact your local authorities and ask for the correct method of disposal.
For Switzerland: Used electrical or electronic equipment can be returned free of charge to the dealer, even if you don’t purchase a new product. Further collection facilities are listed on the homepage of www.swico.ch or www.sens.ch
B. Information on Disposal for Business Users.
If the product is used for business purposes and you want to discard it:
Please contact your SHARP dealer who will inform you about the take-back of the product. You might be charged for the costs arising from take-back and recycling. Small products (and small amounts) might be taken back by your local collection facilities.
For Spain: Please contact the established collection system or your local authority for take-back of your used products.
If you wish to discard of this product, please contact your local authorities and ask for the correct method of disposal.




Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.
Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.