Manuel d'utilisation / d'entretien du produit BL20P du fabricant Server Technology
Aller à la page of 34
HP ProLiant BL20p p-Class Server Blade 42U Rack with ProLiant BL p-Class System Installed 1. BL p-Class interconnects (2) in BL p-Class Server Blade enclosure (interconnect switch shown) 2. BL20p server blades (8) in BL p-Class Server Blade enclosure 3.
At A Glance Performance dual processor server blade designed with enterprise availability ProLiant BL20p Server Blade includes: Intel® Pentium® III FC-PGA2 1.
ProLiant BL20p Server Blade + BL p-Class Server Blade Enclosure + QuickSpecs HP ProLiant BL20p p-Class Server Blade Overview DA - 11411 Worldwide QuickSpecs — Version 24 — 9.
OR Patch panel Interconnect Switch (fiber or copper based) BL p-Class Interconnects + OR Facility DC BL p-Class power enclosure and power supplies + QuickSpecs HP ProLiant BL20p p-Class Server Blade Overview DA - 11411 Worldwide QuickSpecs — Version 24 — 9.
OR OR Scalable bus bar Mini bus bar Bus boxes BL p-Class power distribution Configuration Steps For a complete configuration of the ProLiant BL20p, do the following: Select BL p-Class server blades: Single Intel Pentium III 1.40 GHz processor, 512-MB ECC SDRAM (2 X 256MB) (230040-B21) or Two Intel Pentium III 1.
or BL p-Class F-GbE Interconnect Kit (with 4 LC 1000 SX and 8 RJ-45 10/100 T/TX external ports) (279720-B21) PLUS 4. Select BL p-Class power enclosure and power supplies based on configuration. Use p-Class sizing tool to help determine power configuration: http://h30099.
Processor Intel Pentium III FC-PGA2 Processor 1.40 GHz Upgradeability Upgradeable to dual processing Cache Memory 512-KB Level 2 Cache Chipset ServerWorks HE- SuperLite Chipset NOTE: For more information regarding ServerWorks, please see the following URL: http://www.
ProLiant BL p-Class Server Blade Enclosure and Interconnects ProLiant BL p-Class Server Blade Enclosure 6U (10.5-inch), 19-inch wide Holds up to 8 ProLiant BL20p servers blades 10 bays per server blad.
ProLiant BL p-Class Interconnect Switch Option (Two switches per kit) (Every BL p-Class server blade enclosure requires two interconnect switches OR two RJ-45 patch panels) Provides up to a 32 to 1 server networking cable reduction per server enclosure depending on the mix of BL20p, BL20p G2, and BL40p servers.
ProLiant BL p-Class RJ-45 patch panel and Patch Panel 2 (Two patch panels per kit) (Every BL p-Class server blade enclosure requires two Interconnect switches OR two RJ-45 patch panels) 6U (10.
ProLiant BL p-Class Power System and Rack Information NOTE: To determine power configuration please refer to the ProLiant BL p-Class Overview and Planning Whitepaper and sizing tool, please see the following URL: http://h18000.www1.hp.com/products/servers/proliant-bl/p-class/20p/documentation.
ProLiant Essentials Foundation Pack Software for the ProLiant BL Server ProLiant Essentials Rapid Deployment Pack Rapid Deployment Pack (RDP) is an automated deployment and provisioning solution for all ProLiant servers.
Optional ProLiant Essentials Value Packs Optional software offerings that selectively extend the functionality of an Adaptive Infrastructure to address specific business problems and needs: Workload M.
Dynamic sector repairing and drive parameter tracking (with Smart Array controllers) ProLiant network adapter teaming set-up utility * NOTE: Advanced features such as Graphical Remote Console and Virtual Floppy are included with the BL p-Class server.
Minimum Rack Requirements Mounts in Compaq/HP, Telco racks and Third Party racks that meet the following criteria: Compatible with 19-inch Standard EIA rail sets EIA rail-to-rail depth is 29 - 30" Cabinet depth must be at least 36-inch deep overall (Additional min.
Service and Support Three-year limited warranty, including hardware diagnostic support, pre-failure warranty (coverage of hard drives, memory and processors). The warranty is fully supported by HP Services and a worldwide network of resellers and service providers.
ProLiant BL20p P1400- 512KB, 512MB (1P) 230040-B21 Processor(s) (1) Intel Pentium III 1.40 GHz standard (up to 2 supported) Cache Memory 512-KB Level 2 writeback per processor Memory 512 MB (Standard).
ProLiant BL20p Unique Options Dual NC7780 Gigabit Upgrade Module for ProLiant BL20p 230255-B21 NOTE: The Dual NC7780 Gigabit Upgrade Module replaces two of the standard NC3163 Fast Ethernet Embedded WOL and PXE NICs to two 10/10/1000T NC7780 NICs. NOTE: The GbE Interconnect Switch options support server NIC speeds to 100 Mbps.
NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to URL http://www.
BL p-Class Server Blade Enclosures ProLiant BL p-Class Server Blade Enclosure (ProLiant Essentials Rapid Deployment Pack Trial) 243564-B21 ProLiant BL p-Class Server Blade Enclosure (8 ProLiant Essent.
BL p-Class Power options NOTE: Use p-Class sizing tool to help determine power configuration: http://h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.
USB Easy Access Keyboard (Carbonite) Country Key Code Dash # Description Dash # Description A2M ICELAND ABT HE AB0 TAWA ABU UK AB1 KOR ABV ARA AB2 PRC ABX FIN AB6 FRA ABY DEN AB7 GRK ABZ ITL AB8 TURK .
NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/racks/index.
IP CAT5 Cable 20’, 4 pack 263474-B24 IP CAT5 Cable 40’, 1 pack 263474-B25 Switch Box Connector Kit (high voltage) (Int'l) 144007-B33 TFT5600 Rack Keyboard Monitor 221546-xx1 TFT7210R Rack Mounted 17" Monitor 348373-B21 NOTE: For a complete list of Monitors please view the following URL: http://h18004.
Installation & Start-up Services ProLiant BL p-Class Blade Server Hardware Installation UA219A ProLiant BL p-Class Blade Server Hardware Installation, Electronic UA219E ProLiant BL p-Class Enclosu.
ProLiant BL20p Server Blade (2P Model) (not available in NA) Standard Memory 1024-MB PC133 MHz Registered ECC SDRAM DIMM installed (2 x 512-MB SDRAM DIMM) Standard Memory Plus Optional Memory Up to 3072-MB of SDRAM DIMM memory is available with the installation of optional SDRAM DIMM memory expansion kits.
Compaq ProLiant BL p- Class Server Blade Enclosure Dimensions Height 10.5 in (26.67 cm) Width 17.60 in (44.70 cm) Depth 28.86 in (73.30 cm) Input Specifications Rated input voltage -43 VDC to -53 VDC Nominal -48 VDC Rated input current 62.
Operating and Performance Specifications for RJ- 45 Patch Panel Dimensions Height 10.405 in (26.43 cm) Width 1.535 in (3.899 cm) Depth 27.697 in (70.35 cm) Capability IEEE 802.
SNMP v1 (RFC 1157), MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface Group MIB (RFC 2863), Ethernet MIB (RFC 1643), 802.1Q Extended Bridge MIB, Entity MIB (RFC 2037), RADIUS Authentication MIB, 802.
duplex) Forwarding rate 0.15 million pps per 10/100 port, 1.5 million pps per gigabit port, (64-byte packets) Non-blocking, full-wire speed for all connections Auto-MDI/MDIX, auto-negotiation and auto.
NOTE: Operating temperature has an altitude derating of 34° F per 1,000 ft (1° C per 304.8 m). No direct sunlight. Upper operating limit is 10,000 ft or 70Kpa (3,048 m or 10.1 psia). Upper non- operating limit is 30,000 ft or 30.3 KPa (9,144 m or 4.
Operating and Performance Specifications for Power Enclosures (International) Dimensions Height 5.25 in (13.34 cm) 5.25 in (13.34 cm) Width 17.60 in (44.7 cm) 17.60 in (44.7 cm) Depth 27.15 in (68.96 cm) 27.15 in (68.96 cm) Weights No hot-plug power supplies 47.
Max total power supported 3000 W 9000 W 15,000 W Total max input current at minimum voltage 69.44 A at -43.2VDC 208.32 A at -43.2 VDC 347.2 A at -43.2 VDC (equivalent of 175A per feed) Total max input current at nominal voltage 62.5 A at -48VDC 187.5 A at -48 VDC 312.
measured at the load on any output channel). The ripple and noise is measured over a 20 Hz to 100 MHz frequency band. A resistive load (non-electronic) is used for this measurement. Each output is by-passed to return by a 10uF tantalum capacitor with an ESR less than 100 milli-Ohms in parallel with a 0.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Server Technology BL20P c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Server Technology BL20P - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Server Technology BL20P, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Server Technology BL20P va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Server Technology BL20P, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Server Technology BL20P.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Server Technology BL20P. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Server Technology BL20P ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.