SEARS OWNER'S MANUAL MODEL NO. 390.252158 CAUTION: Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product. Save This Manual For Future Reference.
CONTENTS INTRODUCTION/WARRANTY .......................................... 2 PUMP PERFORMANCE ....................................................... 3 MAJOR COMPONENTS ...................................................... 3 INSTALLATION .............
SAFETY INSTRUCTIONS (Continued) 6. Disconnect electrical power source before installing or working on pump. 7. Ground pump with a ground wire run from grounding lug on motor to a grounded lead in the service panel. 8. Line voltage and frequency of electrical power supply must agree with motor nameplate.
INSTALLATION INSTALLATION Piping in the Well The Shallow Well Water System can be installed on a dug well, drilled well or with a driven point. In a dug or cased well, a foot valve and strainer should be installed for easy priming.
INSTALLATION 1-1/4" 1-1/2" 2" Up to 25 Ft. 25 to 50 Ft. 50 to 200 Ft. Discharge Pipe Sizes When the pump is some distance from the house or point of water use, the discharge pipe size should be increased to reduce pressure losses caused by friction.
ELECTRICAL Disconnect power before working on pump, motor, pressure switch, or wiring. Your Motor Terminal Board (under the motor end cover) if line voltage is 230 Volts or if you have a single voltage and Pressure Switch look like one of those shown below, motor: Connect power supply as shown for your type of Convert to 115 Volts as shown.
OPERATION Priming the Pump NOTICE: To properly prime the pump, install a pipe tee in the discharge piping (see Figure 1, Page 4). To prevent damage to internal-parts, do not start motor until pump has been filled with water. To prime pump: 1. Remove priming plug (Purchase separately; Figure 1, Page 4).
MAINTENANCE NOTICE: DO not overtighten; you may twist studs off of tank. If you have a torque wrench, tighten to 85 inch- pounds torque. 18. Stand tank on feet and reconnect piping. 19. Recharge tank to proper air pressure (see Page 5). 20. Reconnect hoses and pressure switch tube; prime pump (see Page 6).
MAINTENANCE 4. Place back half of pump on flat surface and tap out ce- ramic seat. See Figure 6. I. Screw impeller on shaft (clockwise) while holding shaft with 7/16" open end wrench on shaft flats. This will automatically locate seal in place. See Figure 8.
HELPFUL HINTS How to Handle a Gaseous Well In some areas well water contains gases which must be al- lowed to escape before the water is used. This can be done as shown in Figure 9. A good way of delivering gas-free water is to suspend a pipe, closed at the bottom and open at the top, surrounding the suction pipe.
TROUBLESHOOTING GUIDE TROUBLE POSSIBLE CAUSES REMEDIES Motor will not run 1. Disconnect switch is off 1. Be sure switch is on 2. Fuse is blown 2. Replace fuse 3. Starting switch is defective 3. Replace starting switch 4, Wires at motor are loose, 4. Refer to instructions on wiring disconnected, or wired incorrectly *5.
REPAIR PARTS Pump Only - Model 390.252158 30 29 28 I 2 3 4 11 23 8 9 16 17 24 19 1c lO 2O 22 21 To Order Parts in the U.S.A., Call Sears Product Service, 1-800-366-7278 .
REPAIR PARTS Key Model 390.252158 Part No. 1/2 HP Description 1"* J218-953C 1A 1B 1C 1D 1E 2 3* 4 5 6 7 8 9 10 11 12 13 14 15 16 16 17 18 19 20 2:1" 22 23 24 25 26* 26A 27 28 29 3O U18-1103 .
REPAIR PARTS Tank Only - Model 390.252158 7 REPAIR PARTS Model 390.252158 Key 1/2 HP Qty. No. Part Number Used 1 29135 1 2 3 4 5 6 7 U20-13 U212-160 t U31-446P U36-2.
15.
SEARS OWNER'S MANUAL Model No. 390.252158 The model number of your Shallow Well Water Systemwill be found on the pump body. When requesting service or ordering parts, always give the following in.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Sears 390.252158 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Sears 390.252158 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Sears 390.252158, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Sears 390.252158 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Sears 390.252158, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Sears 390.252158.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Sears 390.252158. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Sears 390.252158 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.