FR
Ryobi logo
Notice d'utilisation officielle

Ryobi YN301PL1

48 pages·5.5 MB·Compresseur d'air·PDF·ENDEITNLJA
Ryobi YN301PL1
Table des matières 25 sections TABLE OF CONTENTS · INTRODUCTION · WARRANTY · GENERAL SAFETY RULES · … AfficherMasquer
Page 2 of the Ryobi YN301PL1 user manual — ELECTRICAL SAFETY Avoid body contact with grounded surfaces such as
Page 2 · cliquer pour agrandir
Page 2

GENERAL SAFETY RULES

Read and understand the operator’s manual for any

accessories or air tools before using.

READ AND UNDERSTAND TOOL LABELS AND MANUAL. Failure to follow warnings could result in DEATH or SERIOUS INJURY.

Additional safety protection will be required in some

environments. For example, the working area may in- clude exposure to a noise level which can lead to hearing damage. The employer and user must ensure that any necessary hearing protection is provided and used by the operator and others in the work area. Some environments will require the use of head protection equipment. When required, the employer and user must ensure that head protection marked to comply with ANSI Z89.1 is used.

SAVE THESE INSTRUCTIONS WORK AREA Keep your work area clean and well lit. Cluttered

benches and dark areas invite accidents. Floor must not be slippery from wax or dust.

Stay alert, watch what you are doing, and use common

sense when operating a power tool. Do not use tool while tired or under the influence of drugs, alcohol, or medication. A moment of inattention while operating power tools may result in serious personal injury.

Do not operate power tools in explosive atmospheres,

such as in the presence of flammable liquids, gases, or dust. Power tools create sparks which may ignite the dust or fumes.

Keep bystanders, children, and visitors away while op-

Dress properly. Do not wear loose clothing or jewelry.

erating tools. Distractions can cause you to lose control.

Contain long hair. Keep your hair, clothing, and gloves away from moving parts. Loose clothes, jewelry, or long hair can be caught in moving parts.

Operate air compressor in an open area at least 18 in.

away from any wall or object that could restrict the flow of fresh air to ventilation openings.

Do not overreach. Keep proper footing and balance

at all times. Proper footing and balance enables better control of the tool in unexpected situations.

ELECTRICAL SAFETY Avoid body contact with grounded surfaces such as

Do not use on a ladder or unstable support. Stable

pipes, radiators, ranges, and refrigerators. There is an increased risk of electric shock if your body is grounded.

footing on a solid surface enables better control of the tool in unexpected situations.

Don’t expose power tools to rain or wet conditions.

TOOL USE AND CARE Do not exceed the pressure rating of any component

Water entering a power tool will increase the risk of elec- tric shock. Do not abuse the cord. Never use the cord to carry the

in the system.

tool or pull the plug from an outlet. Keep cord away from heat, oil, sharp edges, or moving parts. Replace damaged cords immediately. Damaged cords increase the risk of electric shock. When operating a power tool outside, use an outdoor

Protect material lines and air lines from damage or

puncture. Keep hose and power cord away from sharp objects, chemical spills, oil, solvents, and wet floors.

Check hoses for weak or worn condition before each

use, making certain all connections are secure. Do not use if defect is found. Purchase a new hose or notify an authorized service center for examination or repair.

extension cord marked “W-A” or “W”. These cords are rated for outdoor use and reduce the risk of electric shock.

personal safety Use safety equipment. Always wear eye protection.

Release all pressures within the system slowly. Dust

and debris may be harmful.

Dust mask, nonskid safety shoes, hard hat, or hearing protection must be used for appropriate conditions.

Store idle tools out of the reach of children and other

untrained persons. Tools are dangerous in the hands of untrained users.

Always wear eye protection with side shields marked

to comply with ANSI Z87.1, along with hearing protec- tion. Failure to do so could result in objects being thrown into your eyes and other possible serious injuries.

Maintain tools with care. Follow maintenance instruc-

tions. Properly maintained tools are easier to control.

Check for misalignment or binding of moving parts,

The employer and/or user must ensure that proper

breakage of parts, and any other condition that may affect the tool’s operation. If damaged, have the tool serviced before using. Many accidents are caused by poorly maintained tools.

eye protection is worn. We recommend a Wide Vision Safety Mask for use over eyeglasses or standard safety glasses that provide protection against flying particles both from the front and side. Always use eye protection which is marked to comply with ANSI Z87.1.

Never point any tool toward yourself or others.

Ensure compatibility of accessories before using.

Page 3 of the Ryobi YN301PL1 user manual — SPECIFIC SAFETY RULES
Page 3 · cliquer pour agrandir
Page 3

GENERAL SAFETY RULES

Keep the exterior of the air compressor dry, clean, and

Disconnect power supply, open drain valve to de-

free from oil and grease. Always use a clean cloth when cleaning. Never use brake fluids, gasoline, petroleum- based products, or any strong solvents to clean the unit. Following this rule will reduce the risk of deterioration of the enclosure plastic.

compress tank and allow water to drain, and allow air compressor to become cool to the touch before servicing. Turn pressure regulator knob fully counter- clockwise after shutting off compressor.

When servicing a tool, use only identical replacement

SERVICE Tool service must be performed only by qualified re-

parts. Follow instructions in the Maintenance section of this manual. Use of unauthorized parts or failure to follow Maintenance instructions may create a risk of injury.

pair personnel. Service or maintenance performed by unqualified personnel may result in a risk of injury.

SPECIFIC SAFETY RULES

Know your air compressor. Read operator’s manual

Use the air compressor only for its intended use. Do

carefully. Learn its applications and limitations, as well as the specific potential hazards related to this tool. Following this rule will reduce the risk of electric shock, fire, or serious injury.

not alter or modify the unit from the original design or function.

Always be aware that misuse and improper handling

of this tool can cause injury to yourself and others.

Drain tank of moisture after each day’s use.

Do not place over 250 lbs on the work seat. Doing so

If unit will not be used for a while, it is best to leave drain valve open until such time as it is to be used. This will allow moisture to completely drain out and help prevent corrosion on the inside of tank.

could result in damage to the product.

Never step or stand on the work seat. Following this

rule will reduce the risk of serious personal injury.

To reduce the risk of personal injury, do not use work

Risk of Fire or Explosion. Do not spray flammable liquid

seat as a step or platform.

in a confined area. Spray area must be well ventilated. Do not smoke while spraying or spray where spark or flame is present. Keep compressors as far from the spraying area as possible, at least 15 feet from the spraying area and all explosive vapors.

Never leave a tool unattended with the coil air hose

attached.

Do not operate this tool if it does not contain a legible

Risk of Bursting. Do not adjust regulator to result in

Do not continue to use a tool or hose that leaks air or

output pressure greater than marked maximum pressure of attachment and/or the item being inflated. Never use at pressure greater than 135 psi.

does not function properly.

Always disconnect the air supply and power supply

before making adjustments, servicing a tool, or when a tool is not in use.

Use an air pressure gauge periodically while inflating

an item to check the air pressure.

Do not attempt to pull or carry the air compressor by

If connected to a circuit protected by fuses, use time-

the hose.

delay fuses with this product.

Your tool may require more air consumption than this

To reduce the risk of electric shock, do not expose to

air compressor is capable of providing.

rain. Store indoors.

Always follow all safety rules recommended by the

Inspect tank yearly for rust, pin holes, or other

manufacturer of your air tool, in addition to all safety rules for the air compressor. Following this rule will reduce the risk of serious personal injury.

imperfections that could cause it to become unsafe. Never weld or drill holes in the air tank.

Make sure the hose is free of obstructions or snags.

Never direct a jet of compressed air toward people or

Entangled or snarled hoses can cause loss of balance or footing and may become damaged.

animals. Take care not to blow dust and dirt towards yourself or others. Following this rule will reduce the risk of serious injury.

Page 4 of the Ryobi YN301PL1 user manual — SPECIFIC SAFETY RULES
Page 4 · cliquer pour agrandir
Page 4

SPECIFIC SAFETY RULES

Do not use this air compressor to spray chemicals.

This equipment incorporates parts, such as snap

Your lungs can be damaged by inhaling toxic fumes. A respirator may be necessary in dusty environments or when spraying paint. Do not carry while painting.

switches, receptacles, and the like that tend to pro- duce arcs or sparks and, therefore, when located in a garage, it should be in a room or enclosure provided for the purpose, or should be 18 in. (457 mm) or more above the floor.

Inspect tool cords and hoses periodically and, if

damaged, have repaired at your nearest Authorized Service Center. Constantly stay aware of cord location. Following this rule will reduce the risk of electric shock or fire.

Never store tool with air connected. Storing the tool

with air connected can result in unexpected firing and possible serious personal injury.

Never use an electrical adaptor with this grounded

Protect your lungs. Wear a face or dust mask if the

plug.

operation is dusty. Following this rule will reduce the risk of serious personal injury.

Check damaged parts. Before further use of the air

compressor or air tool, a guard or other part that is damaged should be carefully checked to determine that it will operate properly and perform its intended function. Check for alignment of moving parts, binding of moving parts, breakage of parts, mounting, and any other conditions that may affect its operation. A guard or other part that is damaged should be properly repaired or replaced by an authorized service center. Following this rule will reduce the risk of shock, fire, or serious injury.

Do not operate coil air hoses above the rated psi. Fol-

lowing this rule will reduce the risk of serious personal injury.

If the power supply cord is damaged, it must be replaced

only by the manufacturer or by an authorized service center to avoid risk.

Save these instructions. Refer to them frequently and use

them to instruct others who may use this tool. If you loan someone this tool, loan them these instructions also.

Make sure your extension cord is in good condition.

When using an extension cord, be sure to use one heavy enough to carry the current your product will draw. A wire gauge size (A.W.G.) of at least 14 is recommended for an extension cord 25 feet or less in length. A cord exceeding 50 feet is not recommended. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating.

Page 5 of the Ryobi YN301PL1 user manual — SYMBOLS
Page 5 · cliquer pour agrandir
Page 5

SYMBOLS

Ryobi YN301PL1 — SYMBOLS diagram (page 5)
Fig. 1

The following signal words and meanings are intended to explain the levels of risk associated with this product.

Indicates an imminently hazardous situation, which, if not avoided, will result in death or serious injury.

Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury.

Indicates a potentially hazardous situation, which, if not avoided, may result in minor or moderate injury.

(Without Safety Alert Symbol) Indicates a situation that may result in property damage.

Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to operate the product better and safer. SYMBOL NAME DESIGNATION/EXPLANATION Safety AlertIndicates a potential personal injury hazard. Read The Operator’s ManualTo reduce the risk of injury, user must read and understand operator’s manual before using this product. Eye ProtectionAlways wear eye protection with side shields marked to comply with ANSI Z87.1. Wet Conditions AlertDo not expose to rain or use in damp locations. Risk of BurstingDo not adjust regulator to result in output pressure greater than marked maximum pressure of attachment and/or the item being inflated. Never use at pressure greater than 135 psi. Risk of Fire or ExplosionDo not spray flammable liquid in a confined area. Spray area must be well ventilated. Do not smoke while spraying or spray where spark or flame is present. Keep compressors as far from the spraying area as possible, at least 15 feet from the spraying area and all explosive vapors. Risk of Electrical ShockHazardous Voltage: Disconnect from power source before servicing. Compressor must be grounded. Hot SurfaceTo reduce the risk of injury or damage, avoid contact with any hot surface. Risk to BreathingAir obtained directly from the air compressor should never be used to supply air for human consumption.
Page 6 of the Ryobi YN301PL1 user manual — DISCLAIMER OF WARRANTIES
Page 6 · cliquer pour agrandir
Page 6

SYMBOLS

Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to operate the product better and safer.

SYMBOL NAME DESIGNATION/EXPLANATION

AAmperesCurrent HzHertzFrequency (cycles per second) Alternating CurrentType of current VVoltsVoltage Class II Construction

This compressor/pump is not equipped and should not be used to supply breathing quality air. Additional equipment would be necessary to properly filter and purify the air to meet minimal specifications for Grade D breathing as described in Compressed Gas Association Commodity Specification G 7.1 - 1966, OSHA 29 CFR 1910.134. Compressed Gas Association, 4221 Walney Road, Fifth Floor, Chantilly, VA 20151-2923, (703) 788-2700, www.cganet.com Any such additional equipment has not been examined and no implication of proper use for breathing air is intended or implied. If this compressor is altered in any way, existing warranties shall be voided. Ryobi® and One World Technologies, Inc. disclaim any liabilities whatsoever for any loss, personal injury, or damage.

DISCLAIMER OF WARRANTIES

In the event the compressor is used for the purpose of breathing air application and proper in-line safety and alarm equipment is not simultaneously used, existing warranties shall be voided, and Ryobi® disclaims any liabilities whatsoever for any loss, personal injury, or damage.

Page 7 of the Ryobi YN301PL1 user manual — Grounding Instructions
Page 7 · cliquer pour agrandir
Page 7

Electrical

Extension Cords

Electrical Connection

Use only 3-wire extension cords that have 3-prong grounding plugs and 3-pole receptacles that accept the product’s plug. When using a power tool at a considerable distance from the power source, use an extension cord heavy enough to carry the current that the tool will draw. An undersized extension cord will cause a drop in line voltage, resulting in a loss of power and causing the motor to overheat. Use the chart provided below to determine the minimum wire size required in an extension cord. Only round jacketed cords listed by Underwriter’s Laboratories (UL) should be used.

This product is powered by a precision-built electric motor. It should be connected to a power supply that is 120 V, AC only, (normal household current) 60 Hz. Do not operate this product on direct current (DC). A substantial voltage drop will cause a loss of power and the motor will overheat. If the product does not operate when plugged into an outlet, double check the power supply.

Grounding Instructions

This product must be grounded. In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This product is equipped with an electric cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into a matching outlet that is properly installed and grounded in accordance with all local codes and ordinances.

**Ampere rating (on product data plate) 0-2.0 2.1-3.4 3.5-5.0 5.1-7.0 7.1-12.0 12.1-16.0 Cord Length Wire Size (A.W.G.)

25' 16 14 14

50' 16 16 16 14 14 12

100' 16 16 14 12 10 —

Do not modify the plug provided. If it will not fit the outlet, have the proper outlet installed by a qualified electrician.

**Used on 12 gauge - 20 amp circuit. NOTE: AWG = American Wire Gauge

When working with the product outdoors, use an extension cord that is designed for outside use. This is indicated by the letters “W-A” or “W” on the cord’s jacket. Before using an extension cord, inspect it for loose or exposed wires and cut or worn insulation.

Improper installation of the grounding plug is liable to result in a risk of electric shock. When repair or replacement of the cord is required, do not connect the grounding wire to either flat blade terminal. The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire.

Check with a qualified electrician or service personnel if the grounding instructions are not completely understood, or if in doubt as to whether the product is properly grounded.

Keep the extension cord clear of the working area. Position the cord so that it will not get caught on lumber, tools, or other obstructions while you are working with a power tool. Failure to do so can result in serious personal injury.

Repair or replace a damaged or worn cord immediately.

This product is for use on a nominal 120 V circuit and has a grounding plug similar to the plug illustrated in figure 1. Only connect the product to an outlet having the same configuration as the plug. Do not use an adapter with this product.

Check extension cords before each use. If damaged replace immediately. Never use the product with a damaged cord since touching the damaged area could cause electrical shock resulting in serious injury.

See Figure 1, page 16.

Page 8 of the Ryobi YN301PL1 user manual — Carry handle
Page 8 · cliquer pour agrandir
Page 8

GLOSSARY OF TERMS

Air Filter Porous element contained within a metal or plastic housing attached to the compressor cylinder head which removes impurities from the intake air of the compressor. Air Tank Spherical component which contains the compressed air. Amperage Overload Switch (Manual) Automatically shuts off the compressor if the amperage of the electric motor exceeds a predetermined limit. Check Valve Device that prevents compressed air from flowing back from the air tank to the compressor pump. Cut-In Pressure The low pressure at which the motor will automatically restart. Cut-Off Pressure The high pressure at which the motor will automatically shut off. Electric Motor Device which provides the rotational force necessary to operate the compressor pump. NPT (National Pipe Thread) A seal thread tape must be used to provide a leak-free seal on pipe threaded connections.

Pressure Regulator Knob Regulates the outgoing pressure from the air outlet to the tool. It is possible to increase or decrease the pressure at the outlet by adjusting this control knob. Pressure Switch Automatically controls the on/off cycling of the compressor. It stops the compressor when the cut-off pressure in the tank is reached and starts the compressor when the air pressure drops below the cut-in pressure. PSI (Pounds Per Square Inch) Measurement of the pressure exerted by the force of the air. The actual psi is measured by a pressure gauge on the compressor. Pump Produces the compressed air with a reciprocating piston contained within the cylinder. Regulator Pressure Gauge Displays the current line pressure. Line pressure is adjusted by rotating the pressure regulator knob. Safety Valve Prevents air pressure in the air tank from rising over a predetermined limit. SCFM (Standard Cubic Feet Per Minute) or CFM (Cubic Feet Per Minute) A unit of measure of air delivery. Tank Pressure Gauge Indicates the pressure in the air tank.

FEATURES

PRODUCT SPECIFICATIONS Air Tank Capacity 3.0 gal.

Tank Pressure Gauge 1.5 in. diameter

Air Delivery 2.0 SCFM @ 90 psi

Regulatory Pressure Gauge 2 in. diameter

Air Pressure 135 psi max.

Net Weight 32 lbs.

Input 120 V, AC only, 60 Hz, 9.0 Amps

KNOW YOUR air compressor See Figure 2, page 16. The safe use of this product requires an understanding of the information on the product and in this operator’s manual as well as a knowledge of the project you are attempting. Before use of this product, familiarize yourself with all operating features and safety rules.

Carry handle

The air compressor has a carry handle for easy transport.

CORD WRAP The cord wrap keeps the cord neatly out of the way for storage.

DRAIN VALVE The drain valve on the tank is for draining condensation to help prevent tank corrosion.

accessory storage The air compressor features a storage space for pneumatic accessories.

Page 9 of the Ryobi YN301PL1 user manual — ASSEMBLY
Page 9 · cliquer pour agrandir
Page 9

FEATURES

Folding HANDLE and hand grips The air compressor is equipped with conveniently placed hand grips for lifting and a folding handle that can be adjusted for storage and transportation.

REGULATOR PRESSURE GAUGE The current line pressure is displayed on the regulator pressure gauge. This pressure can be adjusted by rotating the pressure regulator knob.

HEAVY-DUTY plastic housing The sturdy plastic housing frames the air compressor to help protect the gauges and controls from damage due to impact.

Safety valve The safety valve is designed to automatically release air if the air tank pressure exceeds the preset maximum.

Side Connect storage Areas The side connect storage areas can secure up to two pneumatic nailers.

integrated Coil hose retainer with 25-FT. AIR HOSE This tool is equipped with an integrated coil hose retainer feature that will hold up to 25 feet of coiled 1/4-in. air hose. A 25-ft. coiled hose is included with your air compressor.

tank pressure gauge The tank pressure gauge indicates the pressure of the air in the tank.

OIL-FREE PUMP The oil-free pump reduces the need for maintenance.

vertical storage The air compressor has been designed to safely stow in the horizontal or upright position.

pressure regulator knob Use the pressure regulator knob to adjust the amount of air being delivered through the hose. Pressing down on the knob will lock it into place. This prevents movement of the knob caused by vibration during use.

work seat The air compressor has a built in work seat that can hold up to 250 lbs.

QUICK COUPLER The air compressor has a 1/4-in. quick connect coupler located on the side of the unit.

ASSEMBLY

UNPACKING This product has been shipped completely assembled.

PACKING LIST 25 ft. Coiled Air Hose Air Compressor with Hose Retainer Barbed Plug (attached to coiled hose) Operator’s Manual This unit may come with additional accessories. Check for an additional list of accessories.

n Carefully remove the product and any accessories from

the box. Make sure that all items listed in the packing list are included.

n Inspect the product carefully to make sure no breakage

or damage occurred during shipping. n Do not discard the packing material until you have care-

fully inspected and satisfactorily operated the product. n If any parts are damaged or missing, please call

1-800-525-2579 for assistance.

Page 10 of the Ryobi YN301PL1 user manual — caution
Page 10 · cliquer pour agrandir
Page 10

ASSEMBLY

Do not attempt to modify this product or create accessories not recommended for use with this product. Any such alteration or modification is misuse and could result in a hazardous condition leading to possible serious personal injury.

Do not connect to power supply until assembly is complete. Failure to comply could result in accidental starting and possible serious personal injury.

caution

Do not disassemble check valve, tank drain valves or safety relief valve with air in tank — bleed tank. Failure to depressurize tank could result in explosion and/or serious personal injury.

Do not use in an environment that is dusty or otherwise contaminated. Using the air compressor in this type of environment may cause damage to the unit.

APPLICATIONS Air compressors are utilized in a variety of air system applications. Match hoses, connectors, air tools, and accessories to the capabilities of the air compressor. You may use this product for the purposes listed below: Operating some air-powered tools Operating air accessories such as air nozzles and

Do not allow familiarity with tools to make you careless. Remember that a careless fraction of a second is sufficient to inflict severe injury.

inflators Operates some air powered paint spraying products

Always wear eye protection with side shields marked to comply with ANSI Z87.1. Failure to do so could result in objects being thrown in your eyes and other possible serious injuries.

TRANSPORTING THE AIR COMPRESSOR See Figure 3 - 4, page 17. The air compressor should be moved as shown in figure 4. This will help you to avoid damaging the wheels or the air compressor by rolling it over items in its path.

To move the air compressorn Ensure AUTO/OFF switch is in the OFF position and the

This equipment incorporates parts, such as snap switches, receptacles, and the like that tend to produce arcs or sparks and, therefore, when located in a garage, it should be in a room or enclosure provided for the purpose, or should be 18 in. (457 mm) or more above the floor.

air compressor is unplugged.

n Pull the folding handle out

n Facing the back of the air compressor, grasp the folding

handle firmly with one hand.

n Lift the air compressor toward you until it balances on

Do not attach any tools to the open end of the hose until start-up has been completed. Attaching a tool prematurely could result in accidental operation causing serious injury.

the wheels.

n Turn around and pull the unit along behind you to the

desired location.

n Lower the air compressor until it sits securely on a flat

surface.

Page 11 of the Ryobi YN301PL1 user manual — ReSETting the compressor
Page 11 · cliquer pour agrandir
Page 11

TRANSPORTING THE AIR COMPRESSOR up or DOWN STAIRS See Figure 5, page 17.

ReSETting the compressor

When amperage into the air compressor exceeds the specified amperage, the air compressor will automatically shut off. To reset the air compressor: n Turn the air compressor off.

To transport the air compressor down stairs: n Using the carrying handle get a firm grasp of the unit. Lift

the unit into a safe and comfortable carrying position.

n Unplug the air compressor to allow unit to cool and to

trigger reset.

n With proper footing and balance, carry the unit down one

step at a time.

n Plug the air compressor into an approved outlet.

n Use care in transporting the unit down or up stairs to avoid

n Turn the air compressor on.

damage to the stairs, damage to the unit, and personal injury.

n Lower the air compressor until it sits securely on a flat

surface.

Never exceed the air tool’s pressure rating as recommended by the manufacturer. When using this air compressor as an inflation device, always follow the maximum inflation guidelines stated by the manufacturer of the item being inflated.

tool storage See Figure 6 - 7, page 17.

n Pneumatic accessories may be stored in the accessory

compartment.

Always ensure the switch is in the OFF position and the regulator pressure gauge reads zero (0) psi before changing air tools or disconnecting the hose from the air outlet. Failure to do so could result in possible serious personal injury.

of the air compressor using the side connect storage areas. Framing and roofing nailers should not be stowed in these storage areas as they are too large.

CONNECTING/DISCONNECTING HOSES TO THE AIR COMPRESSOR See Figures 8 - 10, pages 17 - 18. When connecting a pneumatic air nailer or other air tool always follow the manufacturer’s recommended start-up procedure. When connecting/disconnecting a hose to the air compressor always do the following: n Ensure AUTO/OFF switch is in the OFF position and the

surface either in the horizontal or upright position.

auto/off See Figure 8, page 17. n Connect the air compressor to a power supply. Turn

the power switch to the AUTO position to power the compressor on, as shown in the start up section of the quick reference label.

air compressor is unplugged. n Confirm that the outlet pressure is at zero (0) psi by fully

turning the regulator knob counterclockwise to fully re- duce air pressure at the outlet.

n To turn the air compressor off, turn the power switch to

the OFF position.

compressor. n Connect the air compressor to a power supply and turn

power switch to the AUTO position.

Page 12 of the Ryobi YN301PL1 user manual — ReSETting the compressor
Page 12 · cliquer pour agrandir
Page 12

n Allow unit to reach max pressure as indicated on the tank

DRAINING THE Tank See Figure 12 - 13, page 18. To help prevent tank corrosion and keep moisture out of the air used, the air tank of the compressor should be drained daily. To drain: n Turn the air compressor off, as shown in the shut down

pressure gauge. n Set regulator to desired pressure by rotating pressure

regulator knob. The regulator pressure will appear on the gauge marked as outlet. To disconnect a coiled air hose: n Confirm that the outlet pressure is at zero (0) psi. n When disconnecting a hose from 1/4-in. quick coupler,

section of the quick reference label.

always firmly hold release end of hose. n Pull back on the release sleeve on the 1/4-in. quick

n Pull the ring on the safety valve to release until pressure

coupler.

gauge reads less than 20 psi, as shown in the shut down section of the quick reference label.

n With a firm grip, pull out the quick-connect air fitting that

is attached to the quick coupler.

n Release the ring.

n Rotate drain valves counterclockwise to open, as shown

attaching or Disconnecting PNEUMATIC TOOLs from THE AIR COMPRESSOR NOTE: Each tool is different. Refer to manufacturer’s

in the shut down section of the quick reference label.

n Tilt tank to drain moisture from tank into a suitable

container.

instruction before operating a tool in the seated position.

n If drain valve is clogged, release all air pressure, remove

using the air compressor See Figure 11, page 18.

and clean valve, then reinstall.

Unplug the air compressor and release all air from the tank before servicing. Failure to depressurize tank before attempting to remove valve can cause serious personal injury.

Risk of bursting. Do not adjust regulator to result in output pressure greater than marked maximum pressure of attachment and/or the item being inflated. Never use at pressure greater than 135 psi. Failure to heed this warning could result in possible serious personal injury.

n Rotate drain valve clockwise until tightly closed.

checking the Safety Valve See Figure 12, page 18.

Air powered tools may require more air consumption than this air compressor is capable of providing. Check the tool manual to avoid damage to the tool or risk of personal injury.

Do not attempt to tamper with the safety valve. Anything loosened from this device could fly up and hit you. Failure to heed this warning could result in death or serious personal injury.

n Follow the instructions in “Connecting Hoses to the

Air Compressor.”

n Control the amount of air flow with the pressure regulator

The safety valve will automatically release air if the air tank pressure exceeds the preset maximum. The valve should be checked before each day of use by pulling the ring by hand.

knob. Turning the knob fully counterclockwise will completely stop the flow of air, as shown in the start up section of the quick reference label.

n Turn the air compressor on and allow the tank to fill. The

compressor will shut off when the pressure reaches the preset maximum.

n When finished, always drain the tank and unplug the

n Turn the air compressor off.

unit. Never leave the unit plugged in and/or running unattended.

n Pull the ring on the safety valve to release air for three to

five seconds to allow pressurized air to escape. Release the ring. The safety release valve must reset and hold pressure before all compressed air is exhausted from the tank/pressure vessel.

Page 13 of the Ryobi YN301PL1 user manual — NOTE: FIGURES (ILLUSTRATIONS) START ON PAGE 16
Page 13 · cliquer pour agrandir
Page 13

n Any continued loss of air after performing the above steps

indicates a problem with the safety valve. Discontinue use and seek service before continued use of the air compressor.

If air leaks after the ring has been released or if the valve is stuck and cannot be actuated by the ring, do not use the air compressor until the safety valve has been replaced. Use of the air compressor in this condition could result in serious personal injury.

MAINTENANCE

When servicing use only identical Ryobi® replacement parts. Use of any other parts may create a hazard or cause product damage.

Do not at any time let brake fluids, gasoline, petroleum- based products, penetrating oils, etc., come in contact with plastic parts. Chemicals can damage, weaken or destroy plastic which may result in serious personal injury. Electric tools used on fiberglass material, wallboard, spackling compounds, or plaster are subject to accelerated wear and possible premature failure because the fiberglass chips and grindings are highly abrasive to bearings, brushes, commutators, etc. Consequently, we do not recommend using this product for extended work on these types of materials. However, if you do work with any of these materials, it is extremely important to clean the product using compressed air.

Always wear eye protection marked to comply with ANSI Z87.1 during maintenance. If operation is dusty, also wear a dust mask.

Always release all pressure, disconnect from power supply, and allow unit to cool to the touch before cleaning or making repairs on the air compressor.

LUBRICATION

All of the bearings in this product are lubricated with a sufficient amount of high grade lubricant for the life of the unit under normal operating conditions. Therefore, no further lubrication is required.

GENERAL MAINTENANCE

Avoid using solvents when cleaning plastic parts. Most plastics are susceptible to damage from various types of commercial solvents and may be damaged by their use. Use clean cloths to remove dirt, dust, oil, grease, etc.

NOTE: FIGURES (ILLUSTRATIONS) START ON PAGE 16

AFTER SPANISH LANGUAGE SECTION.

Page 14 of the Ryobi YN301PL1 user manual — TROUBLESHOOTING
Page 14 · cliquer pour agrandir
Page 14

TROUBLESHOOTING

Compressor will not run Loss of power or overheating

Check for proper use of extension cord Check to be sure unit is plugged in Check fuse/breaker Replace shop/house blown fuse Reset shop/house breaker, determining why problem happened Unit must be unplugged and allowed to cool for 30 minutes to initiate reset.

Blown shop/house fuse Shop/house breaker open

Pressure switch bad Tank is full of air

Compressor will turn on when tank pressure drops to cut-in pressure

Motor hums but cannot run or runs slowly

Low voltage Wrong gauge wire or length of extension cord Shorted or open motor winding Defective check valve or unloader

Check with voltmeter Check for proper gauge wire and cord length Take compressor to service center Take compressor to service center

Amperage overload protector cuts out repeatedly

Low voltage Lack of proper ventilation/room temperature too high

Check with voltmeter Move compressor to well-ventilated area. Unit must be unplugged and allowed to cool for 30 minutes to initiate reset. Check for proper gauge wire and cord length

Wrong gauge wire or length of extension cord

Air tank pressure drops when compressor shuts off

Loose connections (fittings, tubing, etc.) Loose drain valve/Open drain valve Check valve leaking

Check all connections with soap and water solution and tighten Tighten drain valve/Close drain valve Take compressor to service center

Excessive moisture in discharge air Excessive water in air tank High humidity

Drain tank Move to area of less humidity; use air line filter

Compressor runs continuously Defective pressure switch Excessive air usage

Take compressor to service center Decrease air usage; compressor not large enough for tool’s requirement

Piston rings are worn

Replace piston rings; Call customer service for assistance

Air output lower than normal Broken inlet valves Connections leaking

Take compressor to service center Tighten connections

Show 4 more labels / short text on this page
problem cause solution · No electrical power · Amperage overload open · Replace pressure switch
Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Dépannage

Dépannage

Problèmes fréquents, causes probables et solutions.

ProblèmeCause possibleSolution
Compressor will not runLoss of power or overheating No electrical power Blown shop/house fuse Shop/house breaker open Amperage overload open Pressure switch bad Tank is full of airCheck for proper use of extension cord Check to be sure unit is plugged in Check fuse/breaker Replace shop/house blown fuse Reset shop/house breaker, determining why problem happened Unit must be unplugged and allowed to cool for 30 minutes to initiate reset. Replace pressure switch Compressor will turn on when tank pressure drops to cut-in pressure p.14
Motor hums but cannot run or runs slowlyLow voltage Wrong gauge wire or length of extension cord Shorted or open motor winding Defective check valve or unloaderCheck with voltmeter Check for proper gauge wire and cord length Take compressor to service center Take compressor to service center p.14
Amperage overload protector cuts out repeatedlyLow voltage Lack of proper ventilation/room temperature too high Wrong gauge wire or length of extension cordCheck with voltmeter Move compressor to well-ventilated area. Unit must be unplugged and allowed to cool for 30 minutes to initiate reset. Check for proper gauge wire and cord length p.14
Air tank pressure drops when compressor shuts offLoose connections (fittings, tubing, etc.) Loose drain valve/Open drain valve Check valve leakingCheck all connections with soap and water solution and tighten Tighten drain valve/Close drain valve Take compressor to service center danger: Do not disassemble check valve, tank drain valves or safety relief valve with air in tank — bleed tank p.14
Excessive moisture in discharge airExcessive water in air tank High humidityDrain tank Move to area of less humidity; use air line filter p.14
Compressor runs continuouslyDefective pressure switch Excessive air usage Piston rings are wornTake compressor to service center Decrease air usage; compressor not large enough for tool’s requirement Replace piston rings; Call customer service for assistance p.14
Air output lower than normalBroken inlet valves Connections leakingTake compressor to service center Tighten connections p.14

Poser une question sur : Ryobi YN301PL1

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Ryobi YN301PL1

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Ryobi YN301PL1 manuel PDF

48 pages·5.5 MB·Compresseur d'air·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…