Manuel d'utilisation / d'entretien du produit R-315N du fabricant Pentax
Aller à la page of 30
Instruction M anual Electroni c Total Stati on R-300 SERIES R-315(N)/R-325(N)/R-335(N) R-322(N)/R-323(N) PENTAX Industrial Instruments Co., Ltd..
PRECAUTIONS REGA RDING SAFETY Safety Precautions (M ust be followed) The follow ing items are intend ed to prev ent possibl e injury to t he us er or other people a nd/or dam age to the ins trument be fore it occurs. These safety precauti ons are impor tant to t he safe op eration o f this pro duct and s hould be observed at all ti mes.
PRECAUTIONS REGA RDI NG SAFETY ・ ・ ・ ・ W ARNING Do not star e into the laser bea m directly as this may result in damage to y our eyes. R-300 is a C lass II Las er product. The reflect orless type i s a Class I IIa (3R) laser product. Do not lo ok into the la ser radiatio n apertur e directly as this may result in damage to your ey es.
P1 PRECAUTIONS REGA RDI NG SAFETY ・ ・ ・ ・ C A U T I O N For security , please d o the openi ng inspecti on and inspec tion ev ery a fix ed period and adjustm ent. W hen the laser bea m enters ey es, an unex pected accid ent might b e caused by the blink of ey es.
Check with your local solid w aste officials for details for recy cling. ・ P2 Usage Prec autions Survey ing instrume nts are high- precision i nstruments.
P3 PRECAUTIONS REGA RDI NG SAFETY ・ ・ ・ ・ ③ There is a p o ssibility that synthesized values a re calculated and the distance may beco me longer or shorter t han the act ual one w hen the o perator measure t he targ et of slope or sphere or rugg ed shape.
the case and storing th em, apply electric ally resistant tape to t he poles o f the battery . Storing the battery and charger as is may result in fire or burn inj ury due to short-cir cui t. P4 PRECAUTIONS REGA RDI NG SAFETY Avoid storing the instrumen t in places s ubject to extreme hi gh, low or radically fluctua ting temper ature.
P5 CONTENTS PRECAUTIONS REG ARDING S AFETY Safety Precautions Usage Precautions CONTENT S 1 BEFORE USING THE INSTRUMENT 1-1 Names of Parts 1-2 Unpacking and Packing 1-2 Standard eq uipment 1-4 Attachi.
P6 1 BEFORE USING THE INSTRUME NT 1 BEFORE USING THE INSTRUME NT 1-1 Names of Parts Focusing knob AF button Laser indi cator Battery cap Instrum ent he ight mark Batter y latch Batter y pack Teles cop.
P7 1 BEFORE USING THE INSTRUME NT Top handl e Objective lens Centering knob R-335 ( N): Shift type.
・ P8 1-2 Unpacking and P acking Unpacking the In strument from the ca se q Set the cas e dow n gently wi th the lid facing upwards. w Open th e latches w hile pressing down on th e lock (safety mechani sm) and open the l id of the c ase. e Remove the instrument fro m the case.
P9 1 BEFORE USING THE INSTRUME NT ・ ・ ・ ・ 1-4 At taching and Charging the Battery Removing the Battery ① ① ① ① Turn the lock lev er anticlockwise and remove the B attery. ② ② ② ② Lift up the b attery pack and remove it from the instrume nt.
P10 1 BEFORE USING T HE INST RUMENT Remaining Battery Charge W hen the in strument 's power is turn ed on, a bat t ery mark "" will be display ed on the rig ht of the dis play screen. This mark c an be used to check the charge stat us of the ba ttery.
battery is begun. P11 [Detaching of battery] ① Press the lock lev er and sli de the batter y to the lock l ever directio n. ② Detach the ba ttery packing from the batt ery pocket. [Display panel] ① Power supply la mp (red): Turns on when the po wer supply is t urned on.
P12 [How to c h a rge] ① ① ① ① It begins c harging autom atical ly when you set the batter y packing i n the charger which be ams the power sup ply lam p. ② ② ② ② Leave jus t as it is until the char ge is c ompleted. ③ ③ ③ ③ W hen the charge is com pleted, the c harge lamp is turned off .
P13 2 DISPL A Y A ND KE YBOARD 2-1 Display and Keyboard 2-2 Operat ion Key Key Description [POWER] ON/OFF of power supp ly [ESC] Returns to previous s creen or cancels a n operat ion. [Illumination] Turns the illum ination of th e LCD disp lay and t elescop e reticle o n and off.
P14 2 DISPL A Y A ND KE YBOARD 2-3 Function Key Display F. Key Description Mode A 「 「 「 「 MEA S 」 」 」 」 F1 Pressing this key one time mea sure s the distance a nd measure ment type can be selected by I nitial Sett in g 2.
P15 [How to move the menu number] Example: The cursor i s locate d at Menu 1. Press the numeric key 0 and 2 to move to M enu 2. ↓ ANGLE S ET 1.ANGLE/% GRADE :A NGLE 2.H.ANGLE INPUT :092 30’ 20” 3.R/L REVERSE : RIGHT ANGLE S ET 1.ANGLE/% GRADE:ANGLE 2.
P16 2 DISPL A Y A ND KE YBOARD 2-4 A lp hanumeric Input The point name is i nput by the Al phanumetric keys as follow ing. Key Letter under Ke y Letter & Figure or der to input [0] [@][.
P17 3 PREP A R A TION FOR SURVEY ING 3 PREPA RATION FOR SURVEY ING 3-1 Centering and Lev eling of the Instrument Setting up the instrument and the tripod ① ① ① ① Adjust th e tripod le gs so th at a height s uitabl e for obser vation is obtaine d when the ins trum ent is set on th e tripod.
P18 If the Laser key is p ush ed and the laser p lu mmet key is push ed, it bec omes the bright n ess adjust ment scre en o f the laser plum met dev ice. The screen b eco mes dark by ← key and becomes bright by → key The adjust ment is co mp let ed with the E NT key and it returns to e lectronic v ial screen.
P19 3-4 Lev eling w ith C ircular vial Tripod is mat che d according t o t he fo llowing po ints, and expan d and contract and match the v ia l o f the Circul ar v ial to the cent er of the circ le. Shorten a le g which is the nearest the incl in ation of t he v ial or extend the f urt h est leg and draw the vial to t he cent er.
P20 [Leveling] ① ① ① ① Rotate instrument horizontally and make two Leveling screws arbitrarily chosen parallel to the display. ② ② ② ② Turn on the Electronic vial f unction by pushing the Laser key.
P21.
3 PREPA RATION FOR SURVEY ING ・ ・ ・ ・ [Target si ghting by Auto foc us] The Auto focus of R-3 00 series has followi ng two modes. 1. Normal m ode : Pres sing AF butt on focuses on the targ et. 2. Continu ous mode : Pressing AF buttons for two seconds bee ps, and rel easing the key enters into t he Continu ous mode.
3 PREPA RATION FOR SURVEY ING [Auto foc us :Target si ghtin g b y Continuo us mode] ① ① ① ① Loosen t he telescope clamp and horiz ontal clamp scr ews. ② ② ② ② Point the telescope at the target u sing a collimator. ③ ③ ③ ③ Tighten th e above tw o screws.
3 PREPA RATION FOR SURVEY ING [Target si ghting by Manual foc us] ① ① ① ① Loosen t he telescope clamp and horiz ontal clamp scr ews. ② ② ② ② Point the telescope at the target u sing a collimator. ③ ③ ③ ③ Tighten th e above tw o screws.
4 TURNING THE POWER ON 4 TURNING THE POWER ON 4-1 Turning the Power On and Off Pressing the [PO W ER] key causes the ini tial screen. (The [PO W ER] k ey is also used t o turn the power off.) After a fe w seconds, it turns to Electr onic vial screen. Mov e the vial s to center by adj usting the leveling screw s.
4 TURNING THE POWER ON 4-2 Adjustin g LCD Contras t Press [F 4 ] whi le holdin g down the Il lumina tion key to access the scr een for adj usting LCD contrast. Pressing [F1] [ ] will ligh t e n the contrast, while pressing the [F2] [ ] will darken the contrast.
4 TURNING THE POWER ON 4-3 Adjustin g Illumi nation Brigh tness Press [F 5 ] whi le holdin g down the Il lumina tion key to access the scr een for adj usting illumination brightness. Pressing the [F1] w ill decrease brightness, whil e pressing the [F2] w ill increase brightness.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Pentax R-315N c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Pentax R-315N - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Pentax R-315N, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Pentax R-315N va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Pentax R-315N, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Pentax R-315N.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Pentax R-315N. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Pentax R-315N ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.