Manuel d'utilisation / d'entretien du produit SM5200 du fabricant Pelco
Aller à la page of 24
CONFIGURA TION C5619M (8/12) Endura ® SM5200 System Manager.
2 C5619M (8/12) Contents About the We b Configuratio n Applicatio n . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Endura Application Compat ibility .
C5619M (8/12) 3 List of Illustrations 1 SM5200 Web Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2 System T o ols .
4 C5619M (8/12) About the W eb Configuration Application The SM5200 is a netw ork appliance that ser ves as the system manage ment component of the Endura ® IP vide o managemen t system. The SM5200 W eb Configur ation Application a llows users to quickly and easily configur e the SM5200 without insta lling additional soft ware.
C5619M (8/12) 5 Icons throughout the Web interface will provid e you with information about the status of the unit and the validi ty of your sett ings. SAVING CONFIGURATION SETTINGS Click Save in the lower -right corner of any pa ge to commit your settings to the SM52 00.
6 C5619M (8/12) Logging On to the SM5200 NOTES: • The SM5200 W eb Configur ation App lication is compa tible with Micro soft ® Internet Explor er ® versions 9 and later , Mozilla ® Firefox ® versions 8 and later , and Google Chrome ™ versions 16 and late r .
C5619M (8/12) 7 System Status Logging on t o the SM520 0 as an admini strator or clicking the Status tab displays a page detail ing the statu s of the s ystem mana ge r and its components. The SM5200’ s stat us does not update in real time . Click Refres h to gat her current stat us information for your system manager .
8 C5619M (8/12) V IDEO STORAGE From the Pelco Web V iewer , users export reco rded footage onto th e system manager’ s inte grated storage array for safekeeping and f uture access. The SM 5200 suppor ts up to 12 T B of video s torage. The video storage pie ch art displays the percen tages of used and available video storage.
C5619M (8/12) 9 IP Settings Clicking the IP Settings tab displays se ttings rela ting to the co nfiguratio n of your unit ’ s network interfaces and the fa ilover cluste r . T he SM5200 comes equippe d with two ne twork interf aces, allowi ng the unit to act as a gateway to th e Endura ne twork.
10 C5619M (8/12) CONFIGURING THE SECOND ARY NETWORK INTERFACE 1. Navigate to the IP Settings page. 2. Click the box labele d Use Secondary Ne twork Interface 3.
C5619M (8/12) 11 System Manager Failover Cluster The Failov er Cluster opt ion allows a us er to desig nate a redun dant, second ary SM5200 t o take over Endura syst em management duti es if the primary SM5200 fails. The secondar y SM5200 duplica tes data and sett ings on the primar y unit.
12 C5619M (8/12) System Settings Click the System tab to disp lay settings governing d ate, time, acc ess to the P elco Web Viewer , a nd SNMP operat ion. Figure 6. System Page DATE AND T IME CONFIGURATION The SM5200 acts as a Network T ime server (NTP) for the private En dura network.
C5619M (8/12) 13 USING THE SYSTEM MANAGER AS AN INDEPENDENT T IME SERVER 1. Navigate to the System p age 2. Select the “Use the System Ma nager as an independ ent time server” option. 3. Enter the curre nt date. 4. Enter the curre nt time. 5. Select your T ime zone from the drop down menu .
14 C5619M (8/12) PELCO W EB VIEWER CONFIGURATION The Pelco Web Viewer enables users with appropriat e permissions to view , sea rch, save, and do wnload video clip s from cameras on the Endura network without installing software.
C5619M (8/12) 15 8. Select Remote A ccess under Services . Figure 7. Select System Permissions 9. Click OK. Users assigned this role can now lo g on to the Pelco W eb V iewer . W EB SERVER PORT CONFIGURATION The SM520 0’ s Web services on ly accept co nnections over HTTPS.
16 C5619M (8/12) SNMP CONFIGURATION The SM5200 sup ports SNMP v2c and v3 commun ications. Y ou can gather status inf ormation ab out your system m anager by issuing GET requests or configuring the unit to send traps to a trap manager . CONFIGURING SNMP V2C 1.
C5619M (8/12) 17 DHCP Setup In the DHCP ta b, you can configur e your system mana ger as a DHCP server for the Endura netw ork. Click the DHCP tab to manage t h e unit’ s DHCP settings. NOTES: • The system manager will only act as a DHCP server on the prim ary network interface.
18 C5619M (8/12) CONFIGURING DHCP SCOPES 1. Navigate to the DHCP pa ge. 2. Select the scope you wa nt to edit. If you need to create a new DH CP scope, click Add Scope. 3. T ype a label for the scope in the Scope Name box. 4. T ype the scope’ s initial IP addr ess in the St arting IP A ddress field.
C5619M (8/12) 19 DELETING MAC ADDRESS RESERVATIONS 1. Navigate to the DHCP pa ge. 2. Select the scope on which you want to delete MAC address reser vations. 3. Click MAC Address Reservations. 4. Select the address or add resses you want to delete. If you want to delete all MAC add ress reservations, click Sele ct All.
20 C5619M (8/12) LDAP Setup The system manager can co nnect to and validate user credenti als from an Lightweight Directory A ccess Protocol (LDAP) server all owing for the integration of the Endu ra network with single sig n-on service s. The system manager supp orts LDAP fo r Microsoft Active Direc tory .
C5619M (8/12) 21 DISABLING PASSWORD EXPIRATION Y ou must disable pas sword expira tion before enabl ing LD AP to prevent user management conf licts between the syst em manage r and t he LDAP server . 1. Log on to the WS5200 ap plication as an administrat or .
22 C5619M (8/12) Updating the SM5200 Updates for t he SM5200 a re applied t hrough the WS5200 applic ation or En dura Utiliti es; you canno t apply an u pdate using the Web configuratio n applicatio n. NOTE: Applying a software update will ca use the unit t o restart .
PRODUCT W ARRANTY AND RETURN INFORMA TION WARRANTY Pelco will repair or replace, without c harge, any merchandise proved defective in material or workmanship for a pe riod of one ye ar after the date of shipment.
Pelco by Schneider Electric 3500 Pelco Way Clovis, California 93612-5699 United States USA & Canada T el (800) 289-9100 Fax (800) 289-9150 International T el +1 (559) 292-1981 Fax +1 (559) 348-1120 www .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Pelco SM5200 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Pelco SM5200 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Pelco SM5200, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Pelco SM5200 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Pelco SM5200, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Pelco SM5200.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Pelco SM5200. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Pelco SM5200 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.