Contentsp.3List of Tablesp.3Important Safeguards and Warningsp.41. Installation and servicing should only be done by qualified service personnel and conform to all local codes.p.42. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.p.43. Only use replacement parts recommended by Pelco.p.44. After replacement/repair of this unit’s electrical components, conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry.p.45. The installation method and materials should be capable of supporting four times the weight of the enclosure, pan/tilt, camera and lens combination.p.46. The camera and lens combination shall not exceed 20 lbs (9.09 kg).p.4Descriptionp.5Modelsp.5Optionsp.5Installationp.6Ceiling Mounting (Flush)p.61. Remove the cover from the mounting bracket. A special socket is provided (fits 1/4" square drive).p.62. Using the mounting bracket (see Figure 4) or the template provided, mark and drill holes in the mounting surface.p.63. Attach the enclosure with the required fasteners.p.64. Route the required cables through the back and/or top.p.65. Mount the camera/lens to the tilt table.p.66. Make all appropriate connections (i.e., camera power, video (coax), lens).p.67. Position the camera and tighten the 1/4-20 fasteners to secure the tilt table in place.p.68. Replace the cover and check that all components clear. Secure the cover with the 1/4-20 “Tampruf” screw provided.p.6Mid-wall Mountingp.6Figure 1. HS1500H Installationp.61. Determine the position for the hood. Using it as a template, mark and drill holes in the mounting surface.p.62. Attach the hood with the required fasteners (minimum 3/8" diameter recommended).p.63. Continue with steps 1-8 listed above in Ceiling Mounting section.p.6HB1500/HB1524 Heater/Blower Kitp.9Recommended Cable Sizep.9Heater/Blower Kit Installationp.101. Remove the cover (Figure 5, item 4).p.102. Attach the heater pads to each side of the mounting frame, below the tilt table assembly.p.103. Attach the PC board/fan assembly to the mounting frame, to the left or right of the tilt table assembly (see Figure 2).p.104. The blower is factory wired to the PCB assembly.p.105. Close and lock the cover.p.10Figure 2. Heather/Blower Installationp.10Figure 3. Heater/Blower Wiring Diagramp.10Tamper Switch installationp.111. Remove the front cover.p.112. Install the bracket/switch and secure with lockwashers and nuts.p.11Tamper Switch Wiringp.11Figure 4. Tamper Switch Installationp.11Maintenancep.11Exploded Assembly Diagramp.12Figure 5. HS1500 Enclosure Exploded Assembly Diagramp.12Table A. HS1500 Enclosure Exploded Assembly Parts Listsp.12Specificationsp.13MECHANICALp.13ELECTRICALp.13GENERALp.13Figure 6. HS1500 Enclosure Dimension Drawingp.13
Page 1 of the Pelco hs1500 user manual — I N S T A L L A T I O N
Page 1 · cliquer pour agrandir
Page 1

I N S T A L L A T I O N

HS1500 High-Security Enclosure

Pelco hs1500 — I N S T A L L A T I O N diagram (page 1)
Fig. 1
Page 2 of the Pelco hs1500 user manual
Page 2 · cliquer pour agrandir
Page 2
Page 2 of the Pelco hs1500 user manual
Page 3 of the Pelco hs1500 user manual — Table des matières
Page 3 · Table des matières
Table des matières

Table des matières

Contentsp.3List of Tablesp.3Important Safeguards and Warningsp.41. Installation and servicing should only be done by qualified service personnel and conform to all local codes.p.42. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.p.43. Only use replacement parts recommended by Pelco.p.44. After replacement/repair of this unit’s electrical components, conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry.p.45. The installation method and materials should be capable of supporting four times the weight of the enclosure, pan/tilt, camera and lens combination.p.46. The camera and lens combination shall not exceed 20 lbs (9.09 kg).p.4Descriptionp.5Modelsp.5Optionsp.5Installationp.6Ceiling Mounting (Flush)p.61. Remove the cover from the mounting bracket. A special socket is provided (fits 1/4" square drive).p.62. Using the mounting bracket (see Figure 4) or the template provided, mark and drill holes in the mounting surface.p.63. Attach the enclosure with the required fasteners.p.64. Route the required cables through the back and/or top.p.65. Mount the camera/lens to the tilt table.p.66. Make all appropriate connections (i.e., camera power, video (coax), lens).p.67. Position the camera and tighten the 1/4-20 fasteners to secure the tilt table in place.p.68. Replace the cover and check that all components clear. Secure the cover with the 1/4-20 “Tampruf” screw provided.p.6Mid-wall Mountingp.6Figure 1. HS1500H Installationp.61. Determine the position for the hood. Using it as a template, mark and drill holes in the mounting surface.p.62. Attach the hood with the required fasteners (minimum 3/8" diameter recommended).p.63. Continue with steps 1-8 listed above in Ceiling Mounting section.p.6HB1500/HB1524 Heater/Blower Kitp.9Recommended Cable Sizep.9Heater/Blower Kit Installationp.101. Remove the cover (Figure 5, item 4).p.102. Attach the heater pads to each side of the mounting frame, below the tilt table assembly.p.103. Attach the PC board/fan assembly to the mounting frame, to the left or right of the tilt table assembly (see Figure 2).p.104. The blower is factory wired to the PCB assembly.p.105. Close and lock the cover.p.10Figure 2. Heather/Blower Installationp.10Figure 3. Heater/Blower Wiring Diagramp.10Tamper Switch installationp.111. Remove the front cover.p.112. Install the bracket/switch and secure with lockwashers and nuts.p.11Tamper Switch Wiringp.11Figure 4. Tamper Switch Installationp.11Maintenancep.11Exploded Assembly Diagramp.12Figure 5. HS1500 Enclosure Exploded Assembly Diagramp.12Table A. HS1500 Enclosure Exploded Assembly Parts Listsp.12Specificationsp.13MECHANICALp.13ELECTRICALp.13GENERALp.13Figure 6. HS1500 Enclosure Dimension Drawingp.13
Page 4 of the Pelco hs1500 user manual — CAUTION:
Page 4 · cliquer pour agrandir
Page 4

Important Safeguards and Warnings

Prior to installation and use of this product, the following WARNINGS should be observed.

1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
3. Only use replacement parts recommended by Pelco.
4. After replacement/repair of this unit’s electrical components, conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry.
5. The installation method and materials should be capable of supporting four times the weight of the enclosure, pan/tilt, camera and lens combination.
6. The camera and lens combination shall not exceed 20 lbs (9.09 kg).

The product and/or manual may bear the following marks:

This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.

CAUTION:

RISK OF ELECTRIC SHOCK.

This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.

DO NOT OPEN.

CAUTION:

To reduce the risk of electrical shock, do not remove cover. No user- servicable parts inside. Refer servicing to qualified service personnel.

Please thoroughly familiarize yourself with the information in this manual prior to installation and operation.

Page 5 of the Pelco hs1500 user manual — OPTIONS
Page 5 · cliquer pour agrandir
Page 5

Description

The HS1500 is a high security camera enclosure of medium size designed for indoor “corner mount” installation for such applications as elevators, parking garages, classrooms, detention cells, etc., requiring maximum protection from vandalism in an unobtrusive package. Designed to fit flush to the ceiling in a corner, an optional hood (HS1500H) allows the HS1500 to be mounted lower on the wall and still retain the enclosure’s integrity. An impact-resistant clear Lexan window is supplied.

Constructed of heavy gauge steel, the HS1500 will accept most small CCD cameras with fixed focal length lenses ranging in size from 4 mm to 75 mm. There is no exposed mounting hardware securing the HS1500 to its mounting surface. Opening the enclosure can only be accomplished with a specially designed tool, eliminating the possibility of the enclosure being opened by unauthorized personnel. In addition, a factory- installed tamper switch is mounted on the secured access cover.

MODELS

HS1500 High security corner mount enclosure designed to fit flush with the ceiling. For use in applications such as elevators, parking garages, classrooms, detention cells, etc., requiring maximum protection from vandalism in an unobtrusive package.

OPTIONS

HB1500 120 VAC thermostatically controlled heater. Provides 80 watts of heat which activates ON at 40°F; OFF at 60°F. Also includes fan that provides continuous internal air circulation.

HB1524 Same as HB1500 except 24 VAC thermostatically controlled heater.

HS1500H Hood for mid-wall mounting of HS1500 enclosure.

Page 6 of the Pelco hs1500 user manual — MID-WALL MOUNTING
Page 6 · cliquer pour agrandir
Page 6

Installation

NOTE:

The four (4) fasteners required to secure the HS1500 to a wall (minimum 3/8” diameter recommended) are not supplied.

Before installing the HS1500 to a wall, make certain that the mounting surface is able to support the full weight of the enclosure plus the camera and lens.

The tilt table and tilt table mounting brackets may be removed to provide adequate clearance for mounting the enclosure.

CEILING MOUNTING (FLUSH)

To mount the enclosure to a wall (tight to the ceiling), follow the steps outlined below.

1. Remove the cover from the mounting bracket. A special socket is provided (fits 1/4" square drive).
2. Using the mounting bracket (see Figure 4) or the template provided, mark and drill holes in the mounting surface.

NOTE:

A plate is provided to prevent access through the top of this enclosure. If needed, it is mounted with the mounting bracket using the same mounting holes and hardware

3. Attach the enclosure with the required fasteners.
4. Route the required cables through the back and/or top.
5. Mount the camera/lens to the tilt table.
6. Make all appropriate connections (i.e., camera power, video (coax), lens).
7. Position the camera and tighten the 1/4-20 fasteners to secure the tilt table in place.
8. Replace the cover and check that all components clear. Secure the cover with the 1/4-20 “Tampruf” screw provided.

MID-WALL MOUNTING

To mount the HS1500 enclosure mid-wall, use the optional hood, HS1500H, and perform the following steps (see Figure 1):

Pelco hs1500 — MID-WALL MOUNTING diagram (page 6)
Fig. 2
1. Determine the position for the hood. Using it as a template, mark and drill holes in the mounting surface.
2. Attach the hood with the required fasteners (minimum 3/8" diameter recommended).
3. Continue with steps 1-8 listed above in Ceiling Mounting section.

Figure 1. HS1500H Installation

Page 7 of the Pelco hs1500 user manual — Installation
Page 7 · cliquer pour agrandir
Page 7
Pelco hs1500 — Installation diagram (page 7)
Fig. 3 · Installation

(

Page 8 of the Pelco hs1500 user manual — Installation
Page 8 · cliquer pour agrandir
Page 8

(This page intentionally left blank)

Page 9 of the Pelco hs1500 user manual — CAUTION:
Page 9 · cliquer pour agrandir
Page 9

HB1500/HB1524 HEATER/BLOWER KIT

The HB1500/HB1524 heater/blower kits require either 120 VAC or 24 VAC, respectively. The heater provides 80 watts of heat and is thermostatically controlled to turn on at 40°F (4.44°C) and turn off at 60°F (15.56°C). The three-watt fan is on continously to provide internal air circulation.

RECOMMENDED CABLE SIZE

The following cable sizes are the minimum recommended for use with the combination of blower/heater/camera.

CAUTION:

When using a single power source for both the camera and accessories, the camera power consumption must be taken into consideration when determining the wire gauge.

ModelInput VoltagePower ConsumptionCable SizeCable Distance HB1500120 VAC85 Watts22 Awg 20 Awg 18 Awg 18 Awg524 ft (160 m) 834 ft (254 m) 1327 ft (404 m) 2107 ft (642 m) HB152424 VAC85 Watts20 Awg 18 Awg 16 Awg 14 Awg33 ft (10 m) 53 ft (16 m) 84 ft (26 m) 134 ft (41 m)
Page 10 of the Pelco hs1500 user manual — HEATER/BLOWER KIT INSTALLATION
Page 10 · cliquer pour agrandir
Page 10

HEATER/BLOWER KIT INSTALLATION

To install the HB1500/HB1524 heater/blower kit, perform the following steps:

1. Remove the cover (Figure 5, item 4).
2. Attach the heater pads to each side of the mounting frame, below the tilt table assembly.
3. Attach the PC board/fan assembly to the mounting frame, to the left or right of the tilt table assembly (see Figure 2).
4. The blower is factory wired to the PCB assembly.
5. Close and lock the cover.
Pelco hs1500 — HEATER/BLOWER KIT INSTALLATION diagram (page 10)
Fig. 4

Connect the heaters to the PCB assembly as shown in Figure 3.

Pelco hs1500 — HEATER/BLOWER KIT INSTALLATION diagram (page 10)
Fig. 5

Heather/Blower Installation · Heater/Blower Wiring Diagram

Page 11 of the Pelco hs1500 user manual — Maintenance
Page 11 · cliquer pour agrandir
Page 11

TAMPER SWITCH INSTALLATION

The HS1500 enclosure comes standard from the factory with a tamper switch installed. Should it become necessary to install a replacement switch, refer to Figure 4 for the correct position of the bracket/switch and perform the following steps:

1. Remove the front cover.
2. Install the bracket/switch and secure with lockwashers and nuts.

TAMPER SWITCH WIRING

The tamper switch comes with both a “Normally Open” and a “Normally Closed” contact.

For a “Normally Open” circuit, use the “open” and “common” terminals; for a “Normally Closed” circuit, use the “closed” and “common” terminals.

Maintenance

Maintenance performed at regularly scheduled intervals will help prolong the operational life and appearance of the equipment.

Clean the Lexan window with a mild non-abrasive detergent in water and a soft cloth regularly to help maintain picture clarity. For a heavily soiled window, use vinyl cleaner.

Tamper Switch Installation

Page 12 of the Pelco hs1500 user manual — Exploded Assembly Diagram
Page 12 · cliquer pour agrandir
Page 12

Exploded Assembly Diagram

Pelco hs1500 — Exploded Assembly Diagram diagram (page 12)
Fig. 6 · Exploded Assembly Diagram

HS1500 Enclosure Exploded Assembly Diagram

Table A.

HS1500 Enclosure Exploded Assembly Parts Lists

Item No.QtyDescriptionPart Number 1 2 3 4 5 6 7 8 91Bracket, switch, break-in Window, 10" x 9" x .50" drilled MR5 clear Lexan Plate, mounting Cover, front Tilt table Cover, top, corner mount Bracket, mount, tilt table, left Bracket, mount, tilt table, right Switch, tamperHS10004313COMP HS150010009 HS15004001COMP HS15004003COMP HS15004008COMP HS15004023COMP HS20004115COMP HS20004215COMP SWI1DM401 A B C D E F G H I J2 1 2 2 2 4 7 4 4 1Screw, 1/4-20 x 1/2", round, Tampruf #10, SS Screw, 1/4-20 x 3/4", round, Tampruf #10, SS Tape, two-sided, acrylic x inch Bolt, 1/4-20 x 5/8" hex head C/S, SS Nut, hex, 1/4-20, SS Washer, split lock, 1/4" SS Washer, flat 3/16" special, SS Washer, flat 15/16", SS Nut, lock 1-4/20 Nylon insert, SS Socket, Tampruf #10, 1/4" drive (not shown)ZH1/4-20X.50SRT ZH1/4-20X.75SRT ZHTAPE1.00X.025 ZH1/420X.625CH ZH1/4-20NUTCH ZH1/4LWSSL ZH260X562X65C ZH932X1.75X130 ZH1/420NUTCHN ZTSOCKET10
Page 13 of the Pelco hs1500 user manual — GENERAL
Page 13 · cliquer pour agrandir
Page 13

Specifications

MECHANICAL

Window 1/2" (12.7 mm) thick impact and abrasion resistant clear Lexan

Camera Mounting Adjustable tilt table

Maximum Camera/Lens Size Accepts camera/lens combinations (including BNC connector) up to: 8.0" L x 4.0" W x 4.0" H (20.32 cm x 10.16 cm x 10.16 cm)

Enclosure Mounting Four (4) .390" (.99 cm) diameter holes on protected rear surface

Security Tamper-resistant screw. N.O./N.C. switch contact on cover

Tamper Switch Plunger type door switch with “pull to cheat” feature N.O/N.C. contacts clearly marked on body of switch. DM electrical rating 10A, 125V.

ELECTRICAL

Cable Entry Access through back and top

Tamper Switch Wire Leads 1/4" (0.63 cm) quick connect N.O./N.C. clearly marked on switch body 10A, maximum switching current 125V, maximum switching voltage

GENERAL

Construction Formed 10 gauge 0.134" (0.34 cm) steel

Finish Polyester powder coat

Dimensions See Figure 6

Environment Indoor; 32° to 120° (0° to 48.89° C)

Unit Weight 15 lbs 4 oz (6.77 kg)

(Design and product specifications subject to change without notice.)

Pelco hs1500 — GENERAL diagram (page 13)
Fig. 7

HS1500 Enclosure Dimension Drawing

Page 14 of the Pelco hs1500 user manual — Specifications
Page 14 · cliquer pour agrandir
Page 14
Page 14 of the Pelco hs1500 user manual — Specifications
Page 15 of the Pelco hs1500 user manual — REVISION HISTORY
Page 15 · cliquer pour agrandir
Page 15

PRODUCT WARRANTY AND RETURN INFORMATION

WARRANTY

Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship

If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information: 1. Model and serial number 2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number 3. Details of the defect or problem

for a period of one year

after the date of shipment.

Exceptions to this warranty are as noted below:

  • Five years on FT/FR8000 Series fiber optic products.
  • Three years on Genex

Series products (multiplexers, server, and keyboard).

  • Three years on Camclosure

and fixed camera models, except the CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models, which have a five-year warranty.

If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written explanation with the product when returned.

  • Two years on standard motorized or fixed focal length lenses.

Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.

  • Two years on Legacy

, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed dome products.

RETURNS

  • Two years on Spectra

, and PS20 scanners, including when used in continuous motion applications.

In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair).

  • Two years on Esprit

and WW5700 Series window wiper (excluding wiper blades).

  • Two years (except lamp and color wheel) on Digital Light Processing (DLP

) dis- plays. The lamp and color wheel will be covered for a period of 90 days. The air filter is not covered under warranty.

All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.

  • Eighteen months on DX Series digital video recorders, NVR300 Series network video recorders, and Endura

Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate address below.

Series distributed network-based video products.

  • One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.

If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:

Service Department Pelco 3500 Pelco Way Clovis, CA 93612-5699

  • Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes).

Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty.

If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the following:

If the goods are to be sent by a COURIER SERVICE, send the goods to:

Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.

Pelco 3500 Pelco Way Clovis, CA 93612-5699 USA

If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:

Pelco c/o Expeditors 473 Eccles Avenue South San Francisco, CA 94080 USA Phone: 650-737-1700 Fax: 650-737-0933

The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state to state.

This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.

REVISION HISTORY

Manual # Date Comments

C493M 5/90 Original manual. C493M 1/91 Rev. A. Revised to include HB1524 and HS1500H options and heater/blower kit information. C493M 5/91 Rev. B. Figure 2, HS1500H Installation added. C493M 11/93 Rev. C. Exploded assembly diagram and parts list updated. C493M-D 9/95 Rev. D. Revised to include wiring instructions for tamper switch and metric equivalents for specifications. Heater/blower wiring diagram updated to include 24 VAC model. C493M-E 11/95 Rev. E. Revised to include updated tamper switch/bracket part numbers and exploded view diagram. C493M-F 1/96 Rev. F. Revised to include updated specification description, installation instructions, and part numbers for tamper switch update per ECO 95-397. C493M-G 11/97 Rev. G. Revised to new format. Updated heater-blower information to indicate blower operated in continuous duty mode.

Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco. ©Copyright 1997, Pelco. All rights reserved. Endura and ExSite are trademarks of Pelco. DLP is a registered trademark of Texas Instruments, Inc.

Show 11 more labels / short text on this page
® · ® · ® · ® · , Esprit · ® · , ExSite · ™ · ® · ® · ™
Page 16 of the Pelco hs1500 user manual — www.pelco.com
Page 16 · cliquer pour agrandir
Page 16

3500 Pelco Way Clovis, California 93612 USA

USA & Canada Tel800/289-9100 Fax: 800/289-9150
International Tel1-559/292-1981 Fax: 1-559/348-1120

www.pelco.com

ISO 9001

United States | Canada | United Kingdom | The Netherlands | Singapore | Spain | Scandinavia | France | Middle East

Worldwide Headquarters

Poser une question sur : Pelco hs1500

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Pelco hs1500

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Pelco hs1500 manuel PDF

16 pages·287 KB·Caméra de surveillance·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…