Manuel d'utilisation / d'entretien du produit C841M-A du fabricant Pelco
Aller à la page of 16
INST ALLA TION/OPERA TION V A6200 Series Sequential Switcher C841M-A (7/02).
2 C841M-A (7/02) LIST OF ILLUSTRA TIONS Figure Page 1 Jumper Settings - V A6200 Series ............................................................................................... ....................................................................
C841M-A (7/02) 3 IMPORT ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following W ARNINGS should be observed. 1. Installation and servicing should be done only by qualified service personnel and conform to all local codes.
4 C841M-A (7/02) INST ALLA TION 1. Remove the cover from the switcher . 2. Set the jumpers as required for your application. Refer to Figure 1 and T able A. 3. Replace the cover . 4. Place the unit on a flat surface or install it in an equipment rack using the appropriate rack-mount kit.
C841M-A (7/02) 5 Table A. Jumper Settings - VA6200 Series Jumper Position Function JP1 - JP20 A Camera input terminated (75 ohms) B Camera input looping (high impedance) JP23, JP24, JP25, JP26, JP28, .
6 C841M-A (7/02) Figure 2. Fixed Cameras with Terminated Inputs Figure 3. Fixed Cameras with Looping Outputs.
C841M-A (7/02) 7 Figure 4. Movable Cameras with Terminated Inputs and Coaxitron Control Figure 5. Movable Cameras with Looping Outputs and Coaxitron Control.
8 C841M-A (7/02) Figure 6. Connector Assembly.
C841M-A (7/02) 9 OPERA TION T o operate the VA6200 Series Switcher: 1. Plug in the power cord. 2. Select the monitor by pushing the MON 1 or MON 2 button. 3. Press a camera button to view video from the corresponding camera. SEQUENCING T o run a sequence: 1.
10 C841M-A (7/02) DWELL TIME The time between switching from one camera to another is known as the dwell time. The dwell time can be set differently for each camera or it can be set the same (global) for all cameras on a monitor . T o check the dwell time: 1.
C841M-A (7/02) 11 ALARMS The alarm inputs must be enabled or disabled if you connected alarms on the switcher to them. T o enable or disable alarms: 1. Press the MON 1 button. 2. Press the recessed ALARM switch. The switch toggles the alarm inputs on and off.
12 C841M-A (7/02) TROUBLESHOOTING PROBLEM SOLUTION No power Check the fuse . Video output quality poor Check jumper settings (Refer to Figure 1, T able A). (Examples: Squiggly video, poor contrast, picture not centered) Locked system or sequencing not working as desired Reset the switcher .
C841M-A (7/02) 13 SPECIFICA TIONS VIDEO Inputs: T erminating (75 ohms) or looping (high impedance) NTSC and PAL compatible Outputs Monitor 1: 75 ohms Monitor 2: 75 ohms; half duplex (Coaxitron ® compatible).
14 C841M-A (7/02) GENERAL Construction Chassis: Steel, zinc plated Cover: Steel, textured black enamel Panel: Aluminum, with LEXAN ® overlay Dimensions V A6204 Series: 1.75 (H) x 5.50 (W) x 9.25 (D) inches (4.44 x 13.97 x 23.49 cm) V A6208 Series: 1.
C841M-A (7/02) 15 REVISION HISTORY Manual # Date Comments C841M 12/99 Original version. C841M-A 7/02 Updated manual to new format. Removed reference to alarm breakout panel. PRODUCT WARRANTY AND RETURN INFORMA TION Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy , and Spectra are registered trademarks of Pelco.
World Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Pelco C841M-A c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Pelco C841M-A - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Pelco C841M-A, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Pelco C841M-A va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Pelco C841M-A, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Pelco C841M-A.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Pelco C841M-A. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Pelco C841M-A ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.