INST ALLA TION/OPERA TION WCS1-4 Environmental Power Supply C561M-F (8/06).
2 C561M-F (8/06) Important Safeguards and W arnings 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Installation should be done only by qualified serv ice personnel and conform to all local codes.
C561M-F (8/06) 3 Description The WCS1-4 is a single power supply designed for indoor or outdoor applicatio ns and is ideal for use with cameras, domes, and integrated positioning systems such as Spectra ® and Esprit ® . The WCS1-4 power supply has one fused output and is capable of handling up to 4 amps (100 VA) of total load.
4 C561M-F (8/06) Installation MOUNTING INSTRUCTIONS T o mount the power supply directly to a wallboard, wall, or concre te refer to Figure 1 through 3 and do the following: 1. Remove the retaining screw from the door latch of the WCS1-4 power supply .
C561M-F (8/06) 5 FUSE INSTALLATION The WCS1-4 power supply is shipped from the fa ctory with a 1.6-amp fuse installed for 100/120 V AC input power . T o use input power of 240 V AC, c hange the 1.
6 C561M-F (8/06) OUTPUT WIRING T o install the output wiring to the camera, dome, or positioning system, refer to Figure 4 and do the following: 1. Refer to T able A and determine the output connection needed for your camera, dome, or positioning system.
C561M-F (8/06) 7 CABLE CONNECTIONS AND REQUIREMENTS T able A. Wiring Distances The following are the recommended maximum distances to wire the WCS1-4 to a Spectra III or Esprit positioning system. T o determine the correct voltage tap: 1. Pick the unit type.
8 C561M-F (8/06) Maintenance There are no user -serviceable parts except for the fuse. If the transformer in the WCS1-4 does not work properly , the entire environment al power supply needs to be retu rn ed to the factory for repair . Refer to the W arranty and Return Information for instructions on returning the WCS1-4.
C561M-F (8/06) 9 Specifications ELECTRICAL Input V oltage Selectable 100, 120, 240 VAC, 50/60 Hz via the Primary Line Input connector strip Output V oltage/Power Selectable 24 VAC (T ap A), 26 VAC (T ap B), or 28 V AC (T ap C) at 100 VA via the Secondary Output T ap’ s connector strip Fusing One fuse.
10 C561M-F (8/06) Figure 5. WCS1-4 D imensi on Draw ing The materials used in the manufacture of this document and its compo nents are compliant to the requirements of Directive 2002/95/EC.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, witho ut charge, any mer c handise proved defective in ma terial or wo rkmanship for a period of one year after th e date of shipment.
W orldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Pelco C561M-F c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Pelco C561M-F - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Pelco C561M-F, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Pelco C561M-F va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Pelco C561M-F, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Pelco C561M-F.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Pelco C561M-F. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Pelco C561M-F ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.