BB14 Series Intercept ® Back Box Installation/ Operation Manual C454M-C (1/98) Pelco • 300 W. Pontiac Way, Clovis • CA 93612-5699 USA • Pelco Online @ http://www.
2 Pelco Manual C454M-C (1/98) CONTENTS Section Page 1.0 GENERAL .................................................................................................. 5 1.1 IMPORT ANT SAFEGUARDS AND W ARNINGS ............................... 5 1.2 UNP ACKING INSTRUCTIONS .
Pelco Manual C454M-C (1/98) 3 REVISION HISTOR Y Manual # Date Comments C454M — Original version. C454M-A 6/95 Revised to incorporate B.O.M. quantity changes as per ECO# 94-445. Added 4-position terminal block information as per ECO# 94-042. Incorporated new “Front” labeling to B.
4 Pelco Manual C454M-C (1/98) (This page intentionally left blank.).
Pelco Manual C454M-C (1/98) 5 Please thor oughly familiarize yourself with the information in this manual prior to installation and operation. 1.0 GENERAL 1.1 IMPORT ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following WARNINGS should be observed.
6 Pelco Manual C454M-C (1/98) 1.2 UNP ACKING INSTRUCTIONS Unpack and inspect all parts carefully . Be sure to save the shipping carton and any inserts.
Pelco Manual C454M-C (1/98) 7 2.0 DESCRIPTION The BB14 Series of back boxes is part of the IDS14 Intercept ® Series of domes. The IDS14 Series is an integral system that includes a back box (BB14), dome drive or fixed mount (DD14), and dome receiver/driver (DRD14).
8 Pelco Manual C454M-C (1/98) Indoor, Pendant BB14E100 Indoor, black, pendant-mount back box; smoked dome; hard- wire control. (CE, UL) BB14E101 Indoor, black, pendant-mount back box; clear dome; hard-wire control. (CE, UL) BB14E110 Indoor, black, pendant-mount back box; smoked dome; 120 VAC input.
Pelco Manual C454M-C (1/98) 9 3.0 INST ALLA TION 3.1 MOUNTING The Intercept ® Series of domes provide back box configurations for several applica- tions and environments (refer to Figures 12 and 13). Installation instructions for the applications listed below will appear in the following order: 1.
10 Pelco Manual C454M-C (1/98) 3.1.2 Har d Ceiling Mounting For installing the back box in a hard ceiling , an optional backup plate is provided for applications where additional reinforcement to the ceiling structure is needed. T o mount the back box directly into a hard ceiling, perform the following steps.
Pelco Manual C454M-C (1/98) 11 3.1.3 Pendant Mounting The pendant back box is designed to be suspended from a suitable length of 1-1/2” pipe threaded at both ends. This pipe can be interfaced to the IWM Series or IDM4018 wall mounts or to the MRW A wall adapter mount or MRCA ceiling adapter mount.
12 Pelco Manual C454M-C (1/98) 3.2 WIRING INSTRUCTIONS How your back box will be wired depends on the type of unit you have: Units with an on-board receiver/driver Units without an on-board receiver/driver (hard-wire applications) Hardwire refers to installations using a remote receiver/driver or a true hardwire controller .
Pelco Manual C454M-C (1/98) 13 T able A. V ideo Coaxial Cable Requirements Cable T ype* Maximum Distance RG59/U 750 ft (229 m) RG6/U 1,000 ft (305 m) RG1 1/U 1,500 ft (457 m) * Minimum cable requireme.
14 Pelco Manual C454M-C (1/98) Figure 3. 24 V AC Back Box Wiring Diagram (for Dome Drives with Integral Receiver/Driver).
Pelco Manual C454M-C (1/98) 15 Figure 4. 120 V AC Back Box Wiring Diagram (for Dome Drives with Integral Receiver/Driver).
16 Pelco Manual C454M-C (1/98) Figure 5. 230 V AC Back Box W iring Diagram (for Dome Drives with Integral Receiver/Driver).
Pelco Manual C454M-C (1/98) 17 3.2.2 Har d-Wir e or Remote Receiver/Driver Refer to Figures 6 and 7 for wiring diagrams. Refer to T able A for the type of video coaxial cable to use. On models for suspended ceilings or hard ceilings, a plate is provided on the top of the back box with 1/2" and 3/4" conduit knockouts.
18 Pelco Manual C454M-C (1/98) Figure 6. Wiring Diagram, Hard-Wire Control with Heater NOTE: For fixed mount or dome drive with blower/heaters and without integral receiver/driver.
Pelco Manual C454M-C (1/98) 19 Figure 7. W iring Diagram, Hard-W ire Control without Heater NOTE: For use in domes without integral receiver/driver or heaters and blower .
20 Pelco Manual C454M-C (1/98) 3.2.3 Heater/Blower Kit Field Installation The kits are shipped partially assembled, to complete assembly and to install the heater/blower kit perform the following steps: 1. Place the fan over the four (4) unused internally threaded standof fs located on the back plate (refer to Figure 1 1).
Pelco Manual C454M-C (1/98) 21 4.0 EXPLODED ASSEMBL Y DIAGRAMS Figure 8. Suspended Ceiling Back Box Exploded Assembly Diagram T able C. Suspended Ceiling Back Box Exploded Assembly Parts List Item Qua.
22 Pelco Manual C454M-C (1/98) Item Quantity Description Part Number 1 1 T rim ring, white SB262ASSY 2 1 Back box 8141202WA 3 1 Plate, gland 8004130COMP 4 4 Receiver ball stud PT180410001 1 Switch, on.
Pelco Manual C454M-C (1/98) 23 Figure 10. Pendant Back Box Exploded Assembly Diagram T able E. Pendant Back Box Exploded Assembly Part List Item Quantity Description Part Number 1 1 Bezel, black 81441.
24 Pelco Manual C454M-C (1/98) Figure 1 1. Back Plate Exploded Assembly Diagram.
Pelco Manual C454M-C (1/98) 25 T able F . Back Plate Exploded Assembly Parts List (Figure 1 1) Item Quantity Description Part Number 1 2 Latch backup plate 8004244COMP 2 2 Latch 8004105COMP 3 2 Latch bracket 8004143COMP 4 1 T ransformer (120 VAC model only) TRF21243.
26 Pelco Manual C454M-C (1/98) 5.0 SPECIFICA TIONS ELECTRICAL Enclosure Back Box Input Voltage: 24 VAC or 120 VAC Power Requirements Receiver/Driver: 48 vA for 24 VAC and 120 VAC dome drives Blower continuous duty: One (1) at 30 cfm, 1.92 watts, 24 VDC One (1) at 33 cfm, 6.
Pelco Manual C454M-C (1/98) 27 Figure 12. Suspended/Hard Ceiling Dimension Drawings Figure 13. Pendant-Mount Dimension Drawing NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES NOTE: .
28 Pelco Manual C454M-C (1/98) 6.0 WARRANTY AND RETURN INFORMA TION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one (1) year after the date of shipment.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Pelco C454M-C c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Pelco C454M-C - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Pelco C454M-C, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Pelco C454M-C va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Pelco C454M-C, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Pelco C454M-C.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Pelco C454M-C. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Pelco C454M-C ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.