Manuel d'utilisation / d'entretien du produit c3401m-a du fabricant Pelco
Aller à la page of 28
INSTALLATION Spectra ® Mini Dome C3401M-A (1/06) Indoor , Ceiling Mount.
.
C3401M-A (1/06) 3 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not block any ventilation openings. Install in accordance with the manufacturer’ s instructions.
4 C3401M-A (1/06) Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
C3401M-A (1/06) 5 Description The Spectra ® Mini is an indoor dome system designed for ceiling applications. The dome can be mounted to the surface of ceilings, or it can be recessed in hard ceilings or standard 2 x 2 ft (61 x 61 cm) tiles in suspended ceilings.
6 C3401M-A (1/06) Installation The following parts are supplied with the Spectra Mini dome system: 1 Dome drive 1 Dome bubble with trim ring 1 Interface cable with a male RJ45-10 connector on one end and four twisted wire pairs on the other end 1 Cover for use with optional translator board 2 #10 x 1.
C3401M-A (1/06) 7 SWITCH SETTINGS Coaxitron control: If you are going to use Coaxitron protocol to communicate with the dome system, you do not have to set any switches.
8 C3401M-A (1/06) *If you are connecting a single dome to a controller , terminate the dome. When connecting more than one dome to a single controller , terminate the dome farthest from the controller .
C3401M-A (1/06) 9 T able C. Switch Settings for SW3 (D-T ype Control) SPECTRA ADDRESS SWITCH SETTING SW3-1 SW3-2 SW3-3 SW3-4 SW3-5 SW3-6 SW3-7 SW3-8 1 ON OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF O.
10 C3401M-A (1/06) 39 ON ON ON OFF OFF ON OFF OFF 40 OFF OFF OFF ON OFF ON OFF OFF 41 ON OFF OFF ON OFF ON OFF OFF 42 OFF ON OFF ON OFF ON OFF OFF 43 ON ON OFF ON OFF ON OFF OFF 44 OFF OFF ON ON OFF O.
C3401M-A (1/06) 11 77 ON OFF ON ON OFF OFF ON OFF 78 OFF ON ON ON OFF OFF ON OFF 79 ON ON ON ON OFF OFF ON OFF 80 OFF OFF OFF OFF ON OFF ON OFF 81 ON OFF OFF OFF ON OFF ON OFF 82 OFF ON OFF OFF ON OFF.
12 C3401M-A (1/06) 115 ON ON OFF OFF ON ON ON OFF 116 OFF OFF ON OFF ON ON ON OFF 117 ON OFF ON OFF ON ON ON OFF 118 OFF ON ON OFF ON ON ON OFF 119 ON ON ON OFF ON ON ON OFF 120 OFF OFF OFF ON ON ON O.
C3401M-A (1/06) 13 153 ON OFF OFF ON ON OFF OFF ON 154 OFF ON OFF ON ON OFF OFF ON 155 ON ON OFF ON ON OFF OFF ON 156 OFF OFF ON ON ON OFF OFF ON 157 ON OFF ON ON ON OFF OFF ON 158 OFF ON ON ON ON OFF.
14 C3401M-A (1/06) 191 ON ON ON ON ON ON OFF ON 192 OFF OFF OFF OFF OFF OFF ON ON 193 ON OFF OFF OFF OFF OFF ON ON 194 OFF ON OFF OFF OFF OFF ON ON 195 ON ON OFF OFF OFF OFF ON ON 196 OFF OFF ON OFF O.
C3401M-A (1/06) 15 229 ON OFF ON OFF OFF ON ON ON 230 OFF ON ON OFF OFF ON ON ON 231 ON ON ON OFF OFF ON ON ON 232 OFF OFF OFF ON OFF ON ON ON 233 ON OFF OFF ON OFF ON ON ON 234 OFF ON OFF ON OFF ON O.
16 C3401M-A (1/06) SURFACE MOUNT INSTALLATION 1. On top of the dome drive is an opening for an optional translator board. The opening has a cover that must be left in place if a translator board is not required. A taller cover is supplied if a translator board is installed.
C3401M-A (1/06) 17 Figure 3. Ceiling Installation Figure 4. Concrete Ceiling Installation Figure 5. Wiring Attached to Ceiling Figure 6. Interface Cable CEILING 6-32 TOGGLE BOL TS (NOT SUPPLIED) OR #8 X 3.
18 C3401M-A (1/06) T able F . Wiring Distances The following are the recommended maximum distances for 24 V AC applications and are calculated with a 10 percent voltage drop. (T en percent is generally the maximum allowable voltage drop for AC-powered devices.
C3401M-A (1/06) 19 RECESSED INSTALLATION SUSPENDED CEILING 1. On top of the dome drive is an opening for an optional translator board. The opening has a cover that must be left in place if a translator board is not required. A taller cover is supplied if a translator board is installed.
20 C3401M-A (1/06) Using the supplied RJ45-10 connector: a. Connect the supplied RJ45-10 connector to your wiring and then plug the connector into the dome drive.
C3401M-A (1/06) 21 Figure 8. Ceiling T ile Installation 6. Line up the tabs on the trim ring with the slots in the dome drive. Snap the trim ring and dome bubble into place.
22 C3401M-A (1/06) HARD CEILING 1. On top of the dome drive is an opening for an optional translator board. The opening has a cover that must be left in place if a translator board is not required. A taller cover is supplied if a translator board is installed.
C3401M-A (1/06) 23 5. Attach the dome drive to the ceiling with the two 3-16 toggle bolts (not supplied). Refer to Figure 9. Figure 9. In-Ceiling Installation to a Fixed Ceiling 6. Line up the tabs on the trim ring with the slots in the dome drive. Snap the trim ring and bubble into place.
24 C3401M-A (1/06) Specifications MECHANICAL Pan Movement 360° continuous pan rotation V ertical T ilt Unobstructed +2° to -92° Manual Pan/T ilt Speeds Pan 0.
C3401M-A (1/06) 25 Horizontal Resolution NTSC >470 TV lines P AL >460 TV lines Minimum Illumination 3.0 lux Sync System AC line lock, phase adjustable via remote control, V-Sync White Balance Au.
26 C3401M-A (1/06).
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products.
United States | Canada | United Kingdom | The Netherlands | Singapore | Spain | Scandinavia | France | Middle East W orldwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Pelco c3401m-a c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Pelco c3401m-a - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Pelco c3401m-a, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Pelco c3401m-a va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Pelco c3401m-a, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Pelco c3401m-a.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Pelco c3401m-a. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Pelco c3401m-a ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.