BSX8-A2-GZ40-10 March 2005 1 BSX8000-5 Br oadband Services Switch Installation Instructions Document Number BSX8-A2-GZ40-10 March 2005 Contents Softwar e and Firmware License Ag reement ................ ................. ................ ..... 1 Product Documentat ion Online .
2 March 2005 BSX8-A2-GZ40-10 Software, including any cop y of either . If you hav e ex ecuted a separate written agreement cov er ing the Software supplied to you under this purchase, such separate written agreement shall gov ern.
BSX8-A2-GZ40-10 March 2005 3 BSX8000-5 Over view The BSX8000-5 Broadband Services Switch provides multi-gig abit Ethernet uplink suppor t capability , full-nonblocking s witching throughp ut, and enhanced management fu nctionality f or the 4000E and 12000E Broadband Loop Carriers (BLCs).
4 March 2005 BSX8-A2-GZ40-10 Unpacking and Inspecting the Equipment HANDLING PRECA UTIONS FOR ST A TIC-SENSITIVE DEVICES This pr oduct is designed to pr otect sensitive components fr om damage due to electr ostatic discharge (ESD) during normal ope ration.
BSX8-A2-GZ40-10 March 2005 5 Installing the BSX8000-5 in a BLC The 12000E is a 14-slot Broa dband Loop Carrier (BLC). Slots 1–1 2 are reserved f or access modules (such as the AIM240 00-48) and slo ts U1 and U2 ar e reserved f or uplink modules .
6 March 2005 BSX8-A2-GZ40-10 MIM-4000F The MIM-4000F is a f our-por t fiber gigabit Ethernet interf ace connecting directly to the gigabit Ether net s w itch in the BSX8000-5 uplink module. MIM-2E1 Plug y our E1 ca ble into one of the RJ45 E1 po r ts on the MIM-2E1 f aceplate.
BSX8-A2-GZ40-10 March 2005 7 Conf iguring Y our Windo ws PC to Communicate with NMS T o communicate with NMS, your PC’ s Ethernet interf ace must be on the same subnet as the BSX8000 -5. F or example , to configure the IP address unde r Windows XP: Procedur e 1.
8 March 2005 BSX8-A2-GZ40-10 The NMS home p age appears ..
BSX8-A2-GZ40-10 March 2005 9 NMS Management Conf iguration Use the Management Configuration scr een to set the u nit’ s IP address and other management par ameters. Procedur e T o configure manag ement par ameters: 1. F rom the home screen, click on t he Management Co nfig b utton.
10 March 2005 BSX8-A2-GZ40-10 3. Click on Submit. Command Line Interface (CLI) CLI System Requirements Straight-Thr ough RJ45 to RJ45 Etherne t Cable – Required f or estab lishing a direct co nnection from the COM port to a DB9 adapte r .
BSX8-A2-GZ40-10 March 2005 11 Connecting a PC Directly T o connect a PC directly to the DSLAM to use the CLI: Procedur e 1. Plug a DB9 to RJ45 adapter into the RS232 serial por t on your PC .
12 March 2005 BSX8-A2-GZ40-10 CLEAR_NVRAM If no interf ace modules are present in th e chassis, clears Non-V olatile Random Access Memory , restoring the DSLAM to factory defaults. DISABLE_TELNET Disables access to the DSLAM using T elnet. DISABLE_TFTP Disables access to the DS LAM using T rivial File T ransfer Protocol.
BSX8-A2-GZ40-10 March 2005 13 LED Indicators T able 2. LED States and Mea nings LED State Indication Additional Information PWR (Po wer) Solid green BSX8000-5 uplink mo dule is receiving power Both BLC power terminals are connected. Solid amber BSX8000-5 uplink mo dule is receiving power Only one of the BLC power terminals is connected.
14 March 2005 BSX8-A2-GZ40-10 10/100/1000BaseT Connectors The uplink ports are 8-pin unk ey ed modular jac ks f or a 10/10 0/1000BaseT interf ace. The MGMT port is an 8-pin modular jac k supporting 10/100BaseT .
BSX8-A2-GZ40-10 March 2005 15 Regulatory Compliance f or Class A Equipment The f ollowing regulatory compliance inf o rmation applies to a BSX8000-5 as installed in a P aradyne BLC .
16 March 2005 BSX8-A2-GZ40-10 *BSX8-A2-GZ40-10* *BSX8-A2-GZ40-10*.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Paradyne BSX8000-5 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Paradyne BSX8000-5 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Paradyne BSX8000-5, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Paradyne BSX8000-5 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Paradyne BSX8000-5, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Paradyne BSX8000-5.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Paradyne BSX8000-5. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Paradyne BSX8000-5 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.