FR
Panamax logo
Notice d'utilisation officielle

Panamax MX5102

24 pages·1.6 MB·Parasurtenseur·PDF·ENDEITNLJA
Panamax MX5102
Table des matières 21 sections WIRING FAULT · BANKS · UNSAFE VOLTAGE · O VOLTS IN EST’D BATTERY: 60 MIN · … AfficherMasquer
Page 1 of the Panamax MX5102 user manual — INS00850-EN REV. D 4/09
Page 1 · cliquer pour agrandir
Page 1

MX5102 Instructions A Complete Power Management, Surge Protection, and Battery Backup Solution

WIRING FAULT

BANKS

UNSAFE VOLTAGE

O VOLTS IN EST’D BATTERY: 60 MIN

1 2 3 4

POWER DISPLAY/ UPS TEST

Features:

  • Surge Protection and AVM
  • LiFT Noise Filtration
  • Dual Learning IR Output Controls
  • Rack Ears Included

INS00850-EN REV. D 4/09

  • ® 2009 Panamax, Inc., 1690 Corporate Circle, Petaluma, CA 94954
  • <a href="http://www.panamax.com" rel="nofollow noopener" target="_blank">www.panamax.com</a>
  • 707-283-5900
  • Fax 707-283-5901
Page 3 of the Panamax MX5102 user manual — FCC Notice
Page 3 · cliquer pour agrandir
Page 3

Important Safety Instructions

This manual contains important instructions that should be followed dur- ing installation and maintenance of the UPS and batteries.

Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before at- tempting to unpack, install, or operate.

DO NOT plug the machine into an outlet that is not grounded. If you need to de-energize this equipment, turn off and unplug the UPS.

For pluggable equipment, the socket shall be installed near the equipment and shall be easily accessible.

To avoid electrical shock, a screwdriver must be used to remove screws to open battery cover before replacing battery. Must close battery compartment using screwdriver to tighten screws.

FCC Notice

FCC Notice This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be de- termined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

(3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

(4) Consult the dealer or an experienced radio/TV technician for help. Any special accessories needed for compliance must be specified in the instruction.

(1) Reorient or relocate the receiving antenna.

(2) Increase the separation between the equipment and receiver.

Page 4 of the Panamax MX5102 user manual — Key Features and Functions
Page 4 · cliquer pour agrandir
Page 4

Key Features and Functions

Sequential Start/Shutdown Complex audio/video systems may be susceptible to voltage transients generated internally at start-up/shutdown if all of the equipment is powered on or off at the same time. This can cause speaker “thumps” which are not only annoying but can also damage the speakers and or trip product circuit breakers. The MX5102 is designed to eliminate these transients by providing a “start-up” delay for the High-Current outlets and a “shutdown” delay for the Switched Outlet Banks. This minimizes in rush current issues by allowing the components plugged into the Switched Outlet Banks to power-up and stabilize before any amplifiers and powered subwoofers are turned on. This sequence is reversed during shutdown. The amplifiers and powered subwoofers turn off, their power supplies drain, and then the equipment plugged into the Switched Outlet Banks are turned off.

  • When subjected to a 6,000V (open circuit voltage) / 500A (short circuit current) surge, the MX5102 limits its voltage output to less than 330V peak, UL’s best rating. The MX5102 will withstand, without damage, 10,000A surges, far exceeding the UL requirement of only 3000 Ampere surges.
  • If the magnitude of the surge is greater than the capacity of the surge protection components, the MX5102’s Protect or Disconnect Circuitry will disconnect your equipment in order to protect it. The MX5102 will need to be repaired or replaced by Panamax if this occurs within the 3 yr. product warranty.

Cable/Sat/Antenna Signal Protection Coaxial protection circuits achieve optimum signal quality from our new coaxial protectors that have the smallest signal loss on the market - less than 0.5 db of attenuation from 0 MHz to 2.2 GHz. Our upgraded coaxial protection has been specifically designed to virtually eliminate signal loss. The clamping level of 75V will meet the demands of both cable and satellite voltage while minimizing exposure to damaging spikes and surges.

Voltage Sense Trigger The MX5102 voltage sense trigger input uses a standard 3.5mm (1/8”) mini- mono plug. This feature provides an ON/OFF trigger for the MX5102 using a Direct Current voltage signal. Many components such as pre-amplifiers and receivers have a DC trigger built in, and will transmit a constant power signal when turned on and in use. The presence of this power signal will turn on the MX5102’s switched outlets. When the source component is turned off, the voltage trigger signal is also turned off and the MX5102’s shutdown sequence is initiated. An AC Adapter of the appropriate voltage, plugged into a switched outlet, may also be used if a DC trigger is not built in. When in use the Voltage Sense Trigger overrides the function of the on/off power button.

Telephone Line Protection Digital video recorders and satellite TV receivers require a telephone line con- nection for TV show scheduling and/or Pay-Per-View services. The MX5102 also provides surge protection for this line. One pair of RJ- 11 telephone jacks is provided for this. The clamping level of the MX5102 telephone protector is 267 volts. This will allow typical ring voltage (90-130VAC) and operating bat- tery voltage (-48DC) to pass through the circuit and still protect the modem in your satellite receiver from damage.

Battery Backup Outlet Bank Today’s audio/video systems include several components that greatly benefit from uninterrupted power. Cable boxes and satellite receivers take a substantial amount of time to recover all of the programming information after a power failure. DVRs can continue to record scheduled programs. Projection television bulbs can fail from thermal shock if the power is abruptly interrupted and the television cannot go through the proper cool down cycle. MX5102 includes a bank of 2 Uninterruptible Power Supply (UPS) outlets.

LAN Protection circuits for 10/100 baseT Ethernet lines. Incoming LAN line MUST be plugged into the LINE jack. Patch cord to the equipment MUST be plugged into the EQUIP jacks. 8 wire protection, 50V clamping.

Isolated Banks: LiFT Technology EMI/RFI Noise Filtration with Isola- tion Between Outlet Banks: Your audio/video components are constantly being bombarded by electromag- netic interference (EMI) and radio frequency interference (RFI) through their AC power source. This contaminated power can affect audio/video equipment and will degrade the overall performance of your entire system. Common symptoms of contaminated power include loss of picture detail, dull colors, pops, hisses, hums and visual artifacts. The MX5102 is designed to eliminate noise contamination, supply clean power to your system and provide noise iso-

Learning IR Control The learning function lets you program MX5102 to send standby or shut- down commands to components such as DLP ceiling projectors or rear projection televisions. For example: if the power fails, the projector’s lamp is turned off while battery back-up outlets continue to provide battery power to the projector’s cooling fan. Proper shutdown is ensured and expensive lamps are protected from damage. The MX5102 can learn up to two discrete IR commands to send a single command to two devices, or to send a two- command macro to a single device.

lation between the outlet banks so that any noise created by A/V components plugged into the MX5102 cannot contaminate the power going to equipment plugged into the other outlet banks of the MX5102.

Linear Filtering Technology (LiFT) For improving picture and sound quality nothing filters AC noise better. LiFT evenly eliminates noise across the entire bandwidth, ensuring peak audio and video performance by reducing harmonic distortion and improving the signal- to-noise ratio. With LiFT, you are assured consistent performance and the highest resolution from any audio or video playback system.

Automatic Over & Under Voltage Protection Panamax’s power monitoring circuitry constantly monitors the AC line volt- age for unsafe voltage conditions such as momentary spikes or prolonged over-voltages and under-voltages (brownouts). These unsafe conditions pose a very dangerous threat to all electronic equipment within the home. If the MX5102 senses an unsafe power condition, it will automatically discon- nect your equipment from the power to protect equipment from damage. When MX5102 disconnects from the power, the Battery Backup Outlets are

switched to battery power.

Page 5 of the Panamax MX5102 user manual — Front and Back Panel Descriptions
Page 5 · cliquer pour agrandir
Page 5

Front and Back Panel Descriptions

Power Switch Press the power button to turn the unit ON or OFF.

Unsafe Voltage Indicator This LED will illumi- nate in red to warn the user that an unsafe voltage level is occuring.

Meter Dimmer /UPS Test Button A quick press of the button will cycle the meter and front panel through several levels of brightness. Press and hold the button to initiate an UPS test cycle. During UPS mode, pressing the button will turn off the internal warning buzzer.

Digital Voltmeter/UPS Status Display During normal operation, the digital LED voltmeter indicates the incoming line voltage. If line voltage drops below 90VAC, or exceeds 132VAC, the Unsafe Voltage LED will flash, and during battery backup (UPS) mode the display will indicate the estimated minutes of battery backup time.

Removable Battery Access Panel Easy to remove for battery access and replacement.

Panamax MX5102 — Front and Back Panel Descriptions diagram (page 5)
Fig. 1 · Front and Back Panel Descriptions

Outlet Bank 1 Indicator Illuminated blue when outlet bank 1 is always on.

Outlet Bank 2 Indicator Illuminated blue when outlet bank 2 is switched on.

Outlet Bank 3 Indicator Illuminated blue when outlet bank 3 is switched on.

Outlet Bank 4 Indicator Illuminated blue when outlet bank 4 is on.

Wiring Fault Indicator This LED will illuminate in red to warn the user that a wiring problem such as a bad/missing ground or reversed wiring exists within the AC receptacle. If illuminated, disconnect all equipment and contact an electrician to insure outlet is properly wired.

Outlet Bank 4 Two always on, battery pow- ered, surge protected outlets for connected equipment ensure temporary uninterrupted operation of connected equip- ment during a power failure.

Outlet Bank 3 Two switched, high-current outlets controlled by the front panel Power Button or the DC Trigger input. Bank 3 has a 5 second turn on delay and turns off immediately. The High Current outlet provides power from a low impedance noise filtration circuit that does not limit the current to your equipment. Its output is noise isolated from all other outlet banks.

Circuit Breakers for Overload Protection Resettable circuit breakers provide optimal overload protection.

IR Control Section Indicator LED’s – Indicates status IR Output Jacks – Standard 1/8” (3.5mm) mono jack for connection to an IR flasher (IR flashers not included)

Universal TV Coaxial Jacks 3 pairs of bidirectional protec- tion circuits optimized for satellite, cable, and antenna TV signal lines.

Panamax MX5102 — Front and Back Panel Descriptions diagram (page 5)
Fig. 2 · Front and Back Panel Descriptions

IR OUT __ STATUS _ IR LEARN IR INPUT _

HIGH CURRENT BANK 3 BANK 2 SWITCHED BANK 2 SWITCHED BANK 1 ALWAYS

Outlet Bank 2 Four switched outlets with Linear Filtration Technology (LiFT) controlled by the front panel Power Button or the DC Trigger input. Bank 2 will turn on immediately and turn off after 5 seconds. Its output is noise isolated from all other banks.

Outlet Bank 1 Two always on outlets with Linear Filtration Technology (LiFT). Power will only be turned off under a fault con- dition, or when the Power Button is switched off. Its output is noise isolated from all other outlet banks.

LAN Jack Protection circuit for one 10/100 baseT Ethernet line. Incoming LAN line MUST be plugged into the LINE jack. Patch cord to the equipment MUST be plugged into the EQUIP jacks. 8 wire protection, 50V clamping.

Phone Jack Protection circuit for one standard telephone or pay-per-view lines. Phone circuit is auto-resetting. Incom- ing phone cord MUST be plugged into the LINE jack. Patch cords to the equipment (satellite receiver, digital video recorder, telephone, etc.) MUST be plugged into the EQUIP jacks. 2-wire protection, 270V clamping.

Voltage Sense Trigger Output 3.5mm (1/8”) Mini-Plug jack.

Page 6 of the Panamax MX5102 user manual — MX5102 Operation
Page 6 · cliquer pour agrandir
Page 6

Installing Your MX5102

1. The UPS outlets may be used immediately upon receipt. However, recharging the battery for at least four hours is recommended to ensure that the battery’s maximum charge capacity is achieved. Charge loss may occur during shipping and storage. To recharge the battery, simply leave the unit plugged into an AC outlet. The unit will charge in both the ON as well as the OFF position.
4. Press the latching button to turn the unit on.
5. The rear panel circuit breakers will open and power to the connected equipment will be turned OFF if an overload is detected. To correct this, turn the unit off, unplug one piece of equipment from the UPS outlets, wait 10 seconds, check to make sure that the circuit breakers are reset, and turn the unit on.
2. With the unit OFF and unplugged, plug your equipment into the unit’s rear panel AC outlets. DO NOT plug a space heater, vacuum cleaner, paper shredder or other large electrical device into the UPS outlets. The power demands of these devices will overload and possibly damage the unit.
6. The UPS battery will automatically charge whenever the unit is plugged into an AC outlet.
7. To maintain optimal battery charge, leave the unit plugged into an AC outlet at all times. Note: To store the MX-5102 for an extended period, cover it and store with the battery fully charged. Recharge the battery every three months to ensure battery life .
3. Plug the MX5102 into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e. g. refrigerator, copier, etc.) Avoid using extension cords. If used, the extension cord must be UL or CSA Listed, minimum 14 AWG, 3-wire grounded, and rated for 15 Amps.

MX5102 Operation

When power is lost or disconnected for an under/over voltage fault, Outlet Bank 4 will switch from utility power (power supplied from the power company) to battery power.

Overload Warning When the load connected to Outlet Bank 4 exceeds 100% of the rated power: The display will flash “OL” (overload) The internal buzzer will sound at a quick rate

Normal UPS Operation The display will change from indicating input voltage to the estimated minutes of backup time. The IR output will activate to trigger required shutdown sequences in connected devices.

To remedy the overload: Reduce the load on Outlet Bank 4 by reconnecting one device to an available outlet in Outlet Bank1 (preferred) or Outlet Bank 2.

The internal buzzer will sound for 1 second in 5 second intervals. The buzzer can be turned off by pressing the Meter Dimmer/UPS Test Button.

Press and hold the Meter Dimmer/UPS Test Button for 2 seconds to initiate a test of the battery backup. If the load has been reduced to an acceptable level, MX5102 will return to normal operation.

After power is restored and stabilized, Outlet Bank 4 will automatically switch back to utility power.

Low Battery Warning When the battery gets down to 3 minutes of backup time: the display will flash and the internal buzzer will sound at a quick rate.

When the battery can no longer support the connected load, Outlet Bank 4 is shut off and the buzzer will sound for 5 seconds, one time.

Page 7 of the Panamax MX5102 user manual — MX5102 Advanced Operation
Page 7 · cliquer pour agrandir
Page 7

MX5102 Advanced Operation

A connection to a UPS can benefit the volatile electronic memories found in High-End Home Theater equipment. The MX5102 takes this to the next level with a number of features designed specifically for AC Power back up applications.

3. Point the remote control at the detector window and quickly press and release the appropriate button on the remote control. If no signal is received within 10 seconds, the programming mode is cancelled, the IR1 LED turns off and you will have to start over.

Patent Pending Learning IR Control The learning IR function lets you program the MX5102 to send standby or shut-down commands to components such as DLP ceiling projectors. If the power fails, the projector’s lamps are turned off while the UPS continues providing battery power to the projector’s cooling fan. Proper shutdown is ensured and expensive lamps are protected from damage. Note: This function should only be used with discrete IR codes. Programming an On/Off toggle command could result in the equipment being turned ON during a power failure!

4. The IR1 LED flashes GREEN if the IR signal is sampled and stored in memory.
5. The IR1 LED will flash RED if the IR signal was not learned. Start over at Step 1.
6. Repeat steps 1-5 for IR2.

To clear IR programming: 1. Press and hold the appropriate IR button, release after 2 sec.

IR Power Failure Operation The MX5102 can learn two IR commands. The learned commands will be transmitted on both output jacks so you have the ability to control 2 different pieces of equipment or use a 2-step macro for one compo- nent.

2. The IR LED turns solid Green.
3. Press the button again. The IR code will be erased from memory and the LED will turn off.
1. After a power failure, the IR codes will be sent to both outputs after a 5 second delay. IR code 1 is sent first, followed by IR2 two seconds later.

IR Output Test 1. An IR flasher must be connected to the UPS and in line-of sight to the IR receiver window of the equipment to be controlled in order to verify that the code was learned correctly.

2. There is no IR output after the power is restored to the system.
2. Make sure that the component to be controlled is turned ON.

IR LED Color & Status Off Idle Green, solid: Waiting to receive IR signal Green, flashing: IR signal sampled Red, flashing: Failed to learn IR signal

3. Press and release the IR button. The code for IR will be transmitted on both IR1 and IR2 outputs.
4. If you are testing a 2-step macro, be sure to press the second IR button to transmit that code.

To program IR output: 1. Press and hold the IR1 button for approximately 2 seconds.

5. If the learning process was successful, the controlled equipment should accept the IR command and turn off or go into standby mode .
2. When the IR1 LED turns solid GREEN, release the button (after approx. 2 seconds).
6. Reprogram the IR command if the controlled equipment does not respond.

a. Be sure that the batteries in the “teaching remote” are fresh and do not need to be replaced.

b. If “press & release” (Step 3 in Programming) doesn’t work, try “press & hold” on the remote control button being taught to the UPS.

Page 8 of the Panamax MX5102 user manual — INS00850-EN REV. D 4/09
Page 8 · cliquer pour agrandir
Page 8

Warranty Information

Panamax Power Conditioner Limited Product Warranty Panamax warrants to the purchaser of this Panamax audio/video component style power conditioner, for a period of three (3) years from the date of purchase, that the unit shall be free of defects in design, material or workmanship, and Panamax will repair or replace any defective unit.

5. REQUEST PAYMENTS: Once Panamax has determined that you are entitled to compensation, Panamax will, at its election, either pay you the present fair market value of the damaged equipment, or pay for the cost of the repair, or send you replacement equipment, or pay the equivalence of replacement equipment.

Upgrade Policy Valid only in the United states and Canada If your Panamax UPS sacrifices itself while protecting your connected equipment, you have an option to upgrade to the latest technology. Please go to our web sites www.panamax.com or contact Customer Relations at 800-472-5555 for details.

6. OTHER INSURANCE/WARRANTIES: This coverage is secondary to any existing manufacturer’s warranty, implied or expressed, or any insurance and/or service contract that may cover the loss.
7. EXCLUSIONS: THE PANAMAX CONNECTED EQUIPMENT PROTECTION POLICY DOES NOT APPLY TO: Service charges, installation costs, reinstallation costs; setup cost; diagnostic charges; periodic checkups; routine maintenance; loss of use of the product; costs or expenses arising out of reprogramming or loss of programming and/or data; shipping charges or fees; service calls; loss or damage occasioned by fire, theft, flood, wind, accident, abuse or misuse, and products subject to manufacturer’s recall or similar event.

2 Year Battery Warranty Please contact Panamax Customer Service for information regarding battery replacement and 2-year Battery Warranty.

Panamax Power Conditioner Limited Connected Equipment Protection Policy

8. DISPUTE RESOLUTION: Any controversy or claim arising out of or relating to Panamax’s Connected Equipment Protection Policy, or the alleged breach thereof, shall be settled by arbitration administered by the American Arbitration Association under its Commercial Arbitration Rules. You may file for arbitra- tion at any AAA location in the United States upon the payment of the applicable filing fee. The arbitra- tion will be conducted before a single arbitrator, and will be limited solely to the dispute or controversy between you and Panamax. The arbitration shall be held in any mutually agreed upon location in person, by telephone, or online. Any decision rendered in such arbitration proceedings will be final and binding on each of the parties, and judgment may be entered thereon in a court of competent jurisdic- tion. The arbitrator shall not award either party special, exemplary, consequential, punitive, incidental or indirect damages, or attorney’s fees. The parties will share the costs of arbitration (including the arbitrator’s fees, if any) in the proportion that the final award bears to the amount of the initial claim.

It is the policy of Panamax that it will, at its election, either replace, pay to replace at fair market value, or pay to repair, up to the dollar amount specified below, equipment that is damaged by an AC power, cable, telephone, or lightning surge while connected to a properly installed Panamax power condi- tioner. To be eligible for compensation, repair and or replacement, the power conditioner must shows signs of surge damage or that it is operating outside of design specifications, relative to its surge protection capability, and under all of the circumstances failed to protect your connected equipment.

THE CONNECTED EQUIPMENT POLICY IS SUBJECT TO THE FOLLOWING CONDITIONS AND LIMITATIONS

9. GENERAL: If you have any questions regarding the product warranty or the connected equipment protection policy, please contact the Panamax Customer Relations Department at www.panamax.com The Limited Product Warranty and Connected Equipment Policy herein supersede all previous warranties and/or Connected Equipment repair/replacement policies.
1. ORIGINAL OWNERSHIP REQUIREMENT: Panamax’s connected equipment policy extends to the original purchaser of the Panamax product only and is non-transferable. Original purchase receipts must accompany any product return or claim for connected equipment damage.

THE LIMITED PRODUCT WARRANTY IS THE ONLY WARRANTY PROVIDED WITH THIS PANAMAX PROD- UCT AND ANY OTHER IMPLIED OR EXPRESSED WARRANTIES ARE NON-EXISTENT.

2. PROPER INSTALLATION: Panamax AC protectors must be directly plugged into a properly ground- ed 3-wire AC outlet. Extension cords*, non-grounded two prong adapters, or other non-Panamax surge products must not be used. Building wiring and other connections to protected equipment must conform to applicable codes (NEC or CEC). No other ground wires or ground connections may be used. All wires (including, e.g., AC power lines, telephone lines, signal/data lines, coaxial cable, antenna lead-ins) leading into the protected equipment must first pass through a single Panamax protector designed for the particular application. The protector and the equipment to be protected must be indoors in a dry location, and in the same building. Panamax installation instructions and diagrams must be followed

This warranty may not be modified except in writing, signed by an officer of the Panamax Corpora- tion.

* The use of a Panamax extension cord or equivalent (UL or CSA listed, minimum 14AWG, 3-wire grounded) will not invalidate the warranty.

** Forms are available on the Panamax web site for requesting RAs and opening a claim for connected equipment damage.

3. NOTIFICATION: You must notify Panamax within ten days of any event precipitating request for product replacement or payment for connected equipment damage. A return authorization (RA) num- ber must first be obtained from the Panamax Customer Relations Department at www.panamax.com** before returning the protector Panamax. At this time, you must notify Panamax if you believe you have a claim for damaged connected equipment. Once you obtain an RA number, please mark the number on the bottom of the unit and pack it in a shipping carton/box with enough packing material to protect it during transit. The RA number must also be clearly marked on the outside of the carton. Ship the unit Panamax. Please note that you are responsible for any and all charges related to shipping the unit to Panamax. If connected equipment damage was indicated on your RA request, Panamax will mail you claim kit to be completed and returned within 30 days. A connection diagram of your system will be re- quired as part of the claim kit. Be sure to note its configuration before disconnecting your equipment.

CAUTION: Audio/Video, computer and/or telephone system installations can be very complex systems, which consist of many interconnected components. Due to the nature of electricity and surges, a single protector may not be able to completely protect complex installations. In those cases, a systematic approach using multiple protectors must be employed. Systematic protection requires professional de- sign. AC power, satellite cables, CATV cables, A/V signal line cables or telephone/network lines entering the system that do not pass through a Panamax surge protector will render the Panamax connected equipment protection policy null and void. For additional information on how to protect your system, please contact Panamax before connecting your equipment to the surge protector.

4. DETERMINATION OF FAILURE: Panamax will evaluate the protector for surge damage. The Pana- max protector must show signs of surge damage or must be performing outside (>10%) of design specifications relative to its surge protection capability. Opening the enclosure, tampering with, or modifying the unit in any way shall be grounds for an automatic denial your request for payment. Panamax, after evaluating all information provided, will determine whether or not your request is eligible for payment. If the surge protector shows no signs of AC power or signal line surge damage and is working within design specifications, Panamax will return the unit to you with a letter explaining the test results Exceptions: If a dealer or installer replaces the protector for the customer, replacement will be returned to the dealer installer; or if the protector is a pre-1996 model, it will be replaced; or, for a Canadian customer, the protector will be replaced. Panamax reserves the right to inspect the damaged connected equipment, parts, or circuit boards. Please note that you are responsible for any and all charges related to shipping the damaged equipment to Panamax. Panamax also reserves the right to inspect the customer’s facility. Damaged equipment deemed uneconomical to repair must remain available for inspection by Panamax until the claim is finalized.

More detailed information is available at www.panamax.com

If you have any questions regarding these requirements, please contact Customer Relations.

MODEL - MX5102

DOC. NO. IWS00850_EN REV. A Effective Date 1/8/09

INS00850-EN REV. D 4/09

  • ® 2009 Panamax, Inc., 1690 Corporate Circle, Petaluma, CA 94954
  • <a href="http://www.panamax.com" rel="nofollow noopener" target="_blank">www.panamax.com</a>
  • 707-283-5900
  • Fax 707-283-5901
Page 9 of the Panamax MX5102 user manual — INS00850 REV. D - FR 4/09
Page 9 · cliquer pour agrandir
Page 9

MX5102 Instructions Un completo de administración de energía, protección, y la batería de soluciones de copia de seguridad

WIRING FAULT

BANKS

UNSAFE VOLTAGE

O VOLTS IN EST’D BATTERY: 60 MIN

1 2 3 4

POWER DISPLAY/ UPS TEST

Caractéristiques:

  • Protection contre les surtensions et AVM
  • LiFT Noise Filtration
  • Double Filtration bruit apprentissage IR de sortie
  • Inclus Rack Ears

INS00850 REV. D - FR 4/09

  • ® 2009 Panamax, Inc., 1690 Corporate Circle, Petaluma, CA 94954
  • <a href="http://www.panamax.com" rel="nofollow noopener" target="_blank">www.panamax.com</a>
  • 707-283-5900
  • Fax 707-283-5901
Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Codes d'affichage

Codes d'erreur

La signification des codes d'erreur affichés à l'écran et la façon de les effacer.

CodeSignificationSolution
MX5102$5,000,000 p.8

Poser une question sur : Panamax MX5102

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Panamax MX5102

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Panamax MX5102 manuel PDF

24 pages·1.6 MB·Parasurtenseur·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%