omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info L V800 SERIES Capacitance Point Level Sensors Shop online at U ser ’ s Guide.
Servicing Nor th America: U.S.A.: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.
This manual contains the information necessary to ensure a safe and successful installation. Please read and comply with the section on page 9 of this manual pertaining to SAFETY . Doing so will ensure proper oper- ation of the equipment and the safety of all personnel.
PRE-INST ALLA TION CONSIDERA TIONS 3 Choosing a Location: (See Figure 2) 1) Material Flow - When selecting a location for the LV800, choose a point in the vessel where the probe will be out of the direct flow of incoming and outgoing material to prevent any mechanical damage that may be caused by the pres- sure of the flow.
4 MECHANICAL INST ALLA TION Standard, Food Grade and Stub Probe Mounting: (See Figures 3 & 4) 1) Select a mounting location in accordance with the Pre- Installation Recommendations. 2) If using a welded fitting, cut a hole into the side/top of the vessel corresponding to the mounting connection (1-1/4” NPT or 3/4” NPT).
5 Figure 5 Power Input: (See Figure5) The LV800 is designed to accept either 115VAC or 230VAC (factory set). Verify the intended voltage supply is compatible with the voltage configuration indicated on the electronics and the external nameplate. Connect power as shown in Figure 5.
6 Delay: A potentiometer is provided for setting the time delay between the time material is "sensed" (Yellow LED on) and the time the relay contact output changes (Red LED on). Units have a 1- turn potentiometer. A clockwise rotation will increase the delay from .
TROUBLESHOOTING MAINTENANCE PROBLEM: Sensor will not sense material CAUSE/SOLUTION: 1) Verify power is applied to the sensor. 2) Verify "Sense Adjust." Reposition adjustment clockwise therefore making the probe more sensitive to "difficult to sense" materials.
8 MECHANICALS Standard Probe Stub Probe DIMENSIONS ARE SHOWN IN INCHES WITH MILLIMETER EQUIVALENT IN BRACKETS.
SPECIFICA TIONS SAFETY Power: 115VAC ( ± 15%); 2.5VA; 50/60Hz / 230VAC ( ± 15%); 2.5VA; 50/60Hz Altitude: 6562 ft (2000 m) max Installation Category: II Pollution Degree: 4 (Reduced to 2 by enclosure) Suitable for indoor/outdoor use Ambient Op Temp: -40˚ F (-40˚ C) to +150˚ F (+65˚ C) * Internal Bin Temp: To +176˚ F (+80˚ C) w/alum.
W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months fro m da te o f pur chas e. OMEGA ’ s W ARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time.
M-4168/0405 Where Do I Find Ever ything I Need for Pr ocess Measurement and Contr ol? OM EGA…Of Course! Shop online at omega.com TEMPERA TURE M U Thermocouple, RTD & Thermistor Probes, Connector.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Omega LV800 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Omega LV800 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Omega LV800, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Omega LV800 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Omega LV800, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Omega LV800.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Omega LV800. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Omega LV800 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.