Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, Controllers & Process Monitors Infrared Pyrometers
$ &&%$ ' &#$ $
Transducers & Strain Gauges Load Cells & Pressure Gauges Displacement Transducers Instrumentation & Accessories
( )( * (
✔ ✔ ✔ ✔
Rotameters, Gas Mass Flowmeters & Flow Computers Air Velocity Indicators Turbine / Paddlesheel Systems Totalizers & Batch Controllers


An OMEGA Technologies Company
pH Electrodes, Testers & Accessories Benchtop/Laboratory Meters Controllers, Calibrators, Simulators & Pumps Industrial pH & Conductivity Equipment
# .%&#
✔
Data Acquisition & Engineering Software Communications-Based Acquisition Systems Plug-in Cards for Apple, IBM & Compatibles Datalogging Systems Recorders, Printers & Plotters
, # $&
✔
Heating Cable Cartridge & Strip Heaters Immersion & Band Heaters Flexible Heaters Laboratory Heaters
*$ # ( # $ #$ (
✔
Metering & Control Instrumentation Refractometers Pumps & Tubing Air, Soil & Water Monitors Industrial Water & Wastewater Treatment pH, Conductivity & Dissolved Oxygen Instruments
TX801M SERIES
PROGRAMMABLE ISOLATING MATH FUNCTION TRANSMITTER

$$ #-)&( $
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
OMEGAnetSM On-Line Service http://www.omega.com
Internet e-mail info@omega.com
& / USA: One Omega Drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unau- thorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat, moisture or vibra- tion; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s con- trol. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs.
Canada: 976 Bergar Laval (Quebec) H7L 5A1 Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: canada@omega.com ++ / USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGASM
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESEN- TATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DIS- CLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negliegence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
& +/
Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands Tel: (31) 20 6418405 FAX: (31) 20 6434643 Toll Free in Benelux: 06 0993344 e-mail: nl@omega.com
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
Czech Republic: ul. Rude armady 1868, 733 01 Karvina-Hranice, Czech Republic Tel: 420 (69) 6311627 FAX: 420 (69) 6311114 e-mail: czech@omega.com
France: 9, rue Denis Papin, 78190 Trappes Tel: (33) 130-621-400 FAX: (33) 130-699-120 Toll Free in France: 0800-4-06342 e-mail: france@omega.com
$ #%$$ .% &).%$ & Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent break- age in transit.
Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany Tel: 49 (07056) 3017 FAX: 49 (07056) 8540 Toll Free in Germany: 0130 11 21 66 e-mail: germany@omega.com
FOR WARRANTY RETURNS, please have the following information available BEFORE contact- ing OMEGA: 1. P.O. number under which the product was PUR CHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product.
FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE con tacting OMEGA: 1. P.O. number to cover the COST of the repair, 2. Model and serial number of product, and 3. Repair instructions and/or specific problems relative to the product.
United Kingdom: 25 Swannington Road, P.O. Box 7, Omega Drive, ISO 9001 Certified Broughton Astley, Leicestershire, Irlam, Manchester, LE9 6TU, England M44 5EX, England Tel: 44 (1455) 285520 Tel: 44 (161) 777-6611 FAX: 44 (1455) 283912 FAX: 44 (161) 777-6622 Toll Free in England: 0800-488-488
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. Copyright 1996 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without prior written consent of OMEGA ENGINEERING, INC.
The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, patient connected applications.

Output Range Programming Table. Notes: 1/ Switch status 1 = ON 0 = OFF 2/ Output ranges with '*' beside them reverse the polarity of the output connections.

Programmable Isolating Maths Function Input to DC Current or
Features. Field Programmable Input and Output Ranges. 29 Predefined Math Functions. 12 Bit Resolution. (0.025%) Input to Output Isolation 1.6kV. High Accuracy 0.1%. Universal AC/DC Power Supply. Compact DIN Rail Mount Enclosure. 120 Point User Definable Curve Fitting.
TX801M Specifications. Input -Voltage Field Programmable 0~5Vdc / 0~10Vdc / 1~5Vdc / 2~10Vdc. Minimum Input Resistance = 180kΩ. Maximum Over-range = 24Vdc Continuous. -Current Field Programmable 0~20mAdc / 4~20mAdc. Input Resistance = 250Ω. Maximum Over-range = 50mAdc Continuous. -Maths Functions 29 Field Selectable, Predefined, Maths Functions. RS-232 Interface for Calibration and Testing. (Using a PI-RAC.) -User Defined Curve Up to 120 Point Look-up Table, Linear Interpolation Between Points. RS-232 Interface for Programming of User Curves. (Using a PI-RAC.) IMPORTANT: The RS-232 communications port is NOT ISOLATED from the TX801M inputs.
Dimensions and Mounting.

2 1 8 7
between units.
8.4mm
Universal P/S -Standard High (H) 70~270Vac and 80~380Vdc; 50/60Hz; 4VA. -Standard Mid (M) 24~80Vac and 20~90Vdc; 50/60Hz; 4VA. -Low Voltage (L) 8~30Vac and 8~30Vdc; 50/60Hz; 4VA. -Circuit Sensitivity
3 4 5 6
2 x 4.5mm
Accurate to
8PFA Octal Termination Base
The Proper Installation & Maintenance of TX801M.
MOUNTING. (1) Mount in a clean environment in an electrical cabinet on 35mm, symetrical, mouning rail. (2) Do not subject to vibration or excess temperature or humidity variations. (3) Avoid mounting in cabinets with power control equipment. (4) To maintain compliance with the EMC Directives the TX801M is to be mounted in a fully enclosed steel cabinet. The cabinet must be properly earthed, with appropriate input / output entry points and cabling.
WIRING. (1) A readily accessible disconnect device and overcurrent device must be incorporated in the the power supply wiring. (2) All cables should be good quality overall screened INSTRUMENTATION CABLE with the screen earthed at one end only. (3) Signal Cables should be laid a minimum distance of 300mm from any power cables. (4) For 2 wire current loops and 2 wire voltage signals or 2 wire current signals, Austral Standard Cables B5102ES is recommended. For 3 wire transmitters Austral Standard Cables B5103ES is recommended. (5) It is recommended that you do not ground current loops and use power supplies with ungrounded outputs. (6) Lightning arrestors should be used when there is a danger from this source. (7) Refer to diagrams for connection information.
No liability will be accepted for errors, omissions or amendments to this specification.
COMMISSIONING. (1) Once all the above conditions have been carried out and the wiring checked apply power to the PI-M and allow five minutes for it to stabilize. (2) Take a low (approx 10%) and high (approx 90%) reading of the variable being measured by the transducer supplying the signal to the PI-M, and ensure that this agrees with the level being indicated by the PLC or indicator, etc, that the TX801M is connected into. Adjust for any difference using the Zero and Span trimpots in the top of the PI-M enclosure with a small screwdriver until the two levels agree. (Clockwise to increase the output reading and anti-clockwise to decrease the output reading.)
Quality Assurance Programme. The modern technology and strict procedures of the ISO9001 Quality Assurance Programme applied during design, development, production and final inspection grant long term reliability of the instrument.
MAINTENANCE. (1) Repeat (2) of Commissioning. (2) Do it regularly - at least once every 12 months.
80mm · 40mm 50mm

TX801MInput Range Programming Table. Always set OUTPUT range first, then INPUT range. DIP switches and trimpots are accessed by removing the small rectangular lid on the top of the TX801M enclosure.
2/ All inputs must be of the same signal type. 3/ If using voltage inputs, short unused inputs to 'COM' (terminal 6).

How to Use the Maths Function Formulae. X, Y, and Z are taken as 0 to 1.0000, representing the full input range.
eg. 4.000mA = 0.0000 8.000mA = 0.2500 12.000mA = 0.5000 16.000mA = 0.7500 20.000mA = 1.0000
The selected calculation is then performed on the inputs. The output is then SCALED so the resultant range is between 0 and 1.000. (The scaling factor is the factor the largest output must be scaled by to get the result = 1.) This 0 to 1.000 range represents the full output range, as set by the output DIP switches.
Examples of Input Connection.
Terminations. Output 1 +Ve 2 -Ve
Examples of Using the Maths Function Formulae. NOTE: For these examples inputs and outputs are configured as 4~20mA.

Transducer With Current − or Voltage Output. + 2
Transducer With Current − or Voltage Output. +
Input 3 Xin 4 Yin 5 Zin 6 COM

OFF ON Gain = 1 Gain = 0 Gain = 2 Gain = 0 Gain = 4 Gain = 0 Gain = 8 Gain = 0 Gain =16 Gain = 0 Gain =32 Gain = 0
1/2 Scale in Full Scale in Zin=Voltage Zin=Current Yin=VoltageYin=Current Xin=VoltageXin=Current
M ID H IG H
OFF ON 0% Offset +20% Offset 0% Offset -50% Offset Current O/P Voltage O/P Current O/P Voltage O/P
M
H
S2-FUN C T S1-SP A N S Z