MAN029 Rev Date 10/1 8 /2007 RACKMUX-T15 Rack Mount ANSI Terminal Drawer Installation and Operation Manual RACKMUX ® Series NETWORK TECHNOLOGI ES INCORPORATE D Te l:33 0-5 62 -70 70 Fax :33 0-5 6 2-1 999 1275 D an ner Dr Aurora, OH 44202 www.netwo rkt ec hinc.
i TRADEMARK RACKMUX is a registered trademark of Net work T e chn ologies Inc in the U.S. and other countries COPYRIGHT Copyright © 2004 , 2007 by Network Techno lo gies Inc.
ii TABLE OF CONTENTS Introduction ................................................................................................................... ................................................... 1 Materials .....................................
iii TABLE OF FIGURES Figure 1- Mount RA CKMUX to rack ................................................................................................ ................................................... 4 Figure 2- Position RACKMU X with clear ance to open .
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 1 INTRODUCTION The RACKMUX-T15 (formerly referred to as RACKMUX-T ERMINAL ) Ra ck Mount ANSI Terminal Drawer (RACKMUX) places a VTxx/ANSI Terminal right in the rack for space-saving, conv enient control of SUN or PC-based headless servers.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 2 Options • LCD anti-glare protective glass shiel d - add a "G" to the model when ordering (i.e. RACKMUX-T15 G ) • Telco 2-post style mounting kit- order RL-T 15-TEL • DC Power option- for use with 36-72VDC i n put- add “48V” to the part number (i.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 3 FEA TURES AND FUNCTIONS 1. Power Button- press to turn the LCD monitor ON and OFF 2. Power LED - indicates operation status Green=Power-On, Video Input Signal OK Red = Suspend / Stand-by, or no Video Input Signal 3.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 4 1. INST ALLA TION 1.1 Rack Mounting Instructions 1.1.1 Standard Rack The RACKMUX was designed to be mounte d to a rack and incl udes mounting flanges to make attachment easy. 1. Determine the mounting height in the ra ck for the drawer.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 5 1.1.2 Optional Telc o 2-Post Mounting If the Telco 2-post mounting bracket kit (RL-T15-TEL ) is to be used, sec ure the short and l ong brackets to each side of the drawer as shown in Fig. 3. Apply 2 nuts (supplied) per bracket to se cure the brackets to the drawer.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 6 SUB D 25 male con ne cto r Re ar V iew RACKMUX-T 15 Attach lo cal printe r eit h er b y par all el ca ble to Par all el or by ser ial c able t o Ser ial .
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 7 1.3 Power Up The Terminal 1. Plug in to power ON the RACKMUX. 2. Using the key, unlock the drawer and slid e the keyboard and LCD Disp lay out far enough to raise the display to a comfortable viewing angle.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 8 2.1.4 Default Configuration The terminal is delivered pr e-configured with the following setti ngs suitable for most RS232 serial consol e connections at 9600 baud using VT-100 em ulation.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 9 2.2 Changing The Operating Parameters To select one of the setup menus shown, press the indicat ed function key. - The screen for that menu appear s with the name high lighted. - The fields in the middle of the screen indic ate the parameters that can be changed in that menu.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 10 End of Line Wr ap causes the cursor to move to the start of the next lin e when additional characters are entered at the end of a line.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 11 ---------------------------------------------------------------------------------------------------- ------------------------------------------------- F.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 12 Table 2- Programmab le Keys Enhanced PC-Style Key board Enhanced PC-Style Key board F1 through F12 ENTER (Both ENTER keys are progr ammable) (UP ARROW) .
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 13 ---------------------------------------------------------------------------------------------------- ------------------------------------------------- F.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 14 Table 4- Color Palettes Palette Display Attribute Foreground Color Background Color 0 Normal Reverse (or blank) *1 Intensity *2 Intensity *2 and reverse.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 15 Table 4- Color Palettes (Cont'd) Palette Display Attribute Foreground Color Background Color 6 Normal Reverse (or blank) *1 Intensity *2 Intensity .
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 16 3. LOCAL KEYBOARD COMMANDS Table 5 lists local keyboard comman ds in th e terminal's native mode. Table 5- Local Key board Commands in Native Mode .
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 17 4. CONNECTOR PIN ASSIGNMENT Table 6- Serial Port (Serial 1) Connector Pin Assignments (RS232C 9-pin connecto r) Pin Signal Mnemonic Direction 1 Data car.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 18 5. COMMAND GUIDE 5.1 Commands Supported in ASCII Personalities Table 5-1 lists all the ASCII commands recogniz ed by the t erminal. The native mode code for the command is given in the second column. (The native mode includes WY-32 5,W Y-120 an d WY-60.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 19 Table 10- Commands Supporte d in ASCII Personalities (Cont'd) Command FUNCTION Native Mode Wyse WY-50+ ADDS VP A2 TVI 910+/925 PC Term ACK mode off.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 20 Table 10- Commands Supporte d in ASCII Personalities (Cont'd) FUNCTION Native Mode Wyse WY-50+ ADDS VP A2 TVI 910+/925 PC Term -Program function ke.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 21 Table 10- Commands Supporte d in ASCII Personalities (Cont'd) FUNCTION Native Mode Wyse WY-50+ ADDS VP A2 TVI 910+/925 PC Term Display Memory/Split.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 22 Table 10- Commands Supporte d in ASCII Personalities (Cont'd) FUNCTION Native Mode Wyse WY-50+ ADDS VP A2 TVI 910+/925 PC Term Graphics Charact ers.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 23 Table 10- Commands Supporte d in ASCII Personalities (Cont'd) FUNCTION Native Mode Wyse WY-50+ ADDS VP A2 TVI 910+/925 PC Term Editing (Cont'd.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 24 Table 10- Commands Supporte d in ASCII Personalities (Cont'd) FUNCTION Native Mode Wyse WY-50+ ADDS VP A2 TVI 910+/925 PC Term Print Functions Prin.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 25 5.2 Variable Values for Table 10 Commands answer Up to 20 characters to defin e ans werback message attr Display Attributes attr Display Attributes SPAC.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 26 Variable Values for Table 10 Commands (Cont'd) fcolor Foreground Color fcolor Foreground Color 1 Black 5 Red 2 Bue 6 Magenta 3 Green 7 Yellow 4 Cya.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 27 Variable Values for Table 10 Commands (Cont'd) length Multiple Length of Page G 1xlines Equa l to the nu mber of data lines H 2xlines Dou ble the number of data lines I *b 4xlines Four times the number of data lines *b Available only in WY-50+ p ersonality.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 28 Variable Values for Table 10 Commands (Cont'd) p1 Function Key p1 Function Key 1 F1 6 F 6 2 F2 7 F 7 3 F3 8 F 8 4 F4 9 F 8 5 F5 0 F 10 P2 Function Key 1 Remote 2 Local 3 Normal Page Page 0 page 0 In the 80 columns mode: There hav e 4 pa ges of display memory.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 29 Variable Values for Table 10 Commands (Cont'd) wnd/page Windo w or Page 0 Page 0 or upper window 1 Page 1 or lower window Word Data Word 0 7 bits 1.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 30 Supported VT100, VT220 and Console ANSI Commands, Con t'd Command FUNCTION VT100, VT220 Console AN SI 132-column display CSI ?3 h Same 80-column di.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 31 Supported VT100, VT220 and Console ANSI Commands (Con t'd) final Final characte r final Final character A Designating UK ANSI character set < De.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 32 Supported VT100, VT220 and Console ANSI Commands (Con t'd) Values for “ Psn ” in table on page 56 Psn Color Psn Color Psn Color Psn Color 0 Black 4 Red 8 Gray 12 Lt. Red 1 Blue 5 Magenta 9 Lt.Blue 13 Lt.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 33 Supported VT100, VT220 and Console ANSI Commands (Con t'd) Command FUNCTION VT100, VT220 Console AN SI Editing Functions (Cont 'd) Erase erasa.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 34 Supported VT100, VT220 and Console ANSI Commands, Con t'd kc Unshifted function key kc Unshifted function key 6 F1 38 F7 7 F2 39 F8 8 F3 40 F9 9 F4 41 F10 10 F5 43 F11 37 F6 44 F12 hc Hexadecimal representation of charact er string assigned to the function key.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 35 Supported VT100, VT220 and Console ANSI Commands (Con t'd) Command FUNCTION VT100, VT220 Console AN SI Auxiliary Keypad Modes Auxiliary keypad nume.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 36 Supported VT100, VT220 and Console ANSI Commands, Con t'd Command FUNCTION VT100, VT220 Console AN SI Request keyboard status report CSI ? 26 n Sam.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 37 7. USING PRINTER SER VER IN ETHERNET TERMINAL Introduction There are two ways to send the print jobs to Ethernet Terminal for printing: 1) through LPD protocol, and 2) through TFTP protocol.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 38 Step 4. Make the dir ectory availabl e to LPD main process Basically, the method has the following three proce dures: 1) Assign the spooling daemo n as the ow ner of this directory. 2) Allow the spooling daem on to be able to read from or write to the directory.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 39 7.4 Setup for TFTP When working on the BSD UNIX system, run the setup procedur e under Setup for LPD on pa ge 34. Otherwise run the Setup for LPD omitting step 6. 7.5 TFTP Printing Before using TFTP p rinting, the Ethernet Termin al needs to be in stalle d completely by Setu p for TFTP on page 34 .
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 40 8. ON-SCREEN DISPLA Y (OSD) 8.1 Standard Controls The RACKMUX LCD has 5 standard co ntrol buttons and a power LED. The 5 stand ard c ontrol buttons operate as follows: • The Power button turns the RACKMUX LCD and back light ON and OFF as desired.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 41 8.2.2 Brightness/Contrast Menu Selecting the Brightness/Contrast menu wi ll b ring up a screen in which the user c an a djust the brightness and contrast levels o f the LCD display.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 42 8.2.5 Setup Menu Selecting the Setup menu will brin g up a screen in which the user can adjus t OSD POSITION-the position of t he OSD menus on the L.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 43 9. KEYBOARD FUNCTIONS The keyboard on the RACKMUX has a stan dard co ndensed Windo ws format. To reduce the keyboard size, some ke ys have been assigned multiple functions, accessible via the "Fn" key.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 44 9.2 Number Pad The functionality of a Number Pad on a st andard Windo ws keyboard has been incorporat ed into this keyboard. To substitute the keys of the Number Pad To substitute the keys of the Number Pad: 1.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 45 9.3 Other Uses of the Function Key The Function (" Fn ") key (page 43) will enable other standard keyboar d feat ures in addition to the Number Pad keys (pa ge 44) .
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 46 Figure 13- U.K. (Englis h) keyboard with numeric key pad Figure 14- German keyboard with numeric ke ypad 10. CPU-TO-RACKMUX ETHERNET CROSSOVER CABLE In order to make a direct connection between a CPU and th e ETHERNET conn ector of the RACKMUX, a crossover cable must be used.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 47 1 1. DC POWER OPTION If the RACKMUX has been ordered with the DC Power opti on (“48V” at th e end of the m odel number), a 3-terminal block has been provided for connection to a 36-72 VDC 2A power source.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 48 DIMENSIONAL DRA WINGS 1. 75 I N . 19 . 0 0 I N . Front View of RACK M U X-T15 Slott ed holes f or se curin g termi nal dr awer to r ack 15" L CD Display 2 1 .
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 49 FREQUENTL Y ASKED QUESTIONS Questions and Answers Q. What servers can the monitor be used with? A. All Sun and headless servers to date i nclude at least one serial RS232 port that is used as a console port when no directly connected keyboard is prese nt.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 50 TECHNICAL SPECIFICA TIONS Physical Size (In.) WxDxH 19x21.9x1.725 Weight 23.3 lbs. Temperature 0°~40°C oper ating, -20°~60° C storage Humidity 20% t.
NTI RACKMU X RACKMOUNT ANSI TERM INAL DRAWER 51 TROUBLESHOOTING Each and every piece of every product prod uced by Network Tec hnologies Inc is 100% tested to exacting spec ifications. We make every effort to insure trouble-free installation a nd oper ation of our products.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Network Technologies RACKMUX Series c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Network Technologies RACKMUX Series - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Network Technologies RACKMUX Series, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Network Technologies RACKMUX Series va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Network Technologies RACKMUX Series, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Network Technologies RACKMUX Series.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Network Technologies RACKMUX Series. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Network Technologies RACKMUX Series ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.