Manuel d'utilisation / d'entretien du produit 5800 du fabricant NEC
Aller à la page of 58
NEC Expr ess5800 series Power Console Plus™ User ’ s Guide ONL-4140bN-COMMON-1 19-99-0508.
Preface This manual explains "Power Console Plus" that is used with NEC Express5800 series connected with the LSI Logic disk array controller . This manual is intended for pe rsons who are familiar with W i ndows functions and operation methods.
Content s 1. Overview .................................................................................................................... 1 1.1 Major Functions ..........................................................................................
– 1 – 1. Overview 1.1 MAJOR FUNCTIONS Power Console Plus is a utility to RAID system U se of Power Console Plus enables operations (e.g., monitoring and maintenance) of RAID systems that are constructed on local NEC Express servers and NEC Express servers connected through networks (TCP/IP).
– 2 – 1.2 COMPONENTS Power Console Plus consists of the following six components: SNMP Agent Install SNMP Agent in the NEC Express ser ver in which the MegaRAID controller is installed. MegaRAID Service Monitor Install MegaRAID Service Monitor in the NEC Express server in which the MegaRAID controller is installed.
– 3 – Power Console Plus components to be installed are different between the tar get servers and management PC. Server NEC Express server in which the MegaRAID controller is installed Install the.
– 4 – 2. Server Setup This section explains how to setup the Power Console Plus in the NEC Express server configuring RAID system 2.1 OPERA TING ENVIRONMENT This section explains the operating environmen t required for Power Console Plus to operate.
– 5 – 2.2 PREP ARA TIONS This section explains prerequisites for setup. The driver for the RAID system must be installed. The SNMP service of W indows must be installed. TCP/IP setting for W indows must be completed. Updating of the system must be completed.
– 6 – 2.3 INST ALLA TION T ake the following steps to install Power Console Plus: 1. Power on the server to start W indows 2000 / W indows 2003 Server . 2. Set the provided CD-ROM labeled as "EXP RESSBUILDER" in the CD-ROM drive. 3. Run "SETUP .
– 7 – 6. Enter the password to permit full access to Power Console Plus, and click [Next]. Installation starts. When automatic setup comp letes, [Finish to Setup] screen appears. 7. Select "Y es, I want to restart my computer now" and click [Finish].
– 8 – 2.4 ENVIRONMENT SETUP Set up the environment as explained below . Setting HOSTS File Setting of HOSTS file is needed when control is performed via the network.
– 9 – Modifying REGSER V .DA T File Modification of the management server informati on is necessary when control is performed via the network. Modify management server information registered in the REGSER V .DA T file that is provided/browsed by Power Console Plus.
– 10 – Change of the p assword permitting the full access T o change the password s pecified at installati on that permits the full access, use the password change tool SETP ASS.EXE provided by Power Console Plus. Execute the password change tool SETP ASS.
– 11 – 2.5 UNINST ALLING POWER CONSOLE PLUS T ake the following steps to uninstall Power Console Plus: 1. Power on the server and start W indows. 2. Set the provided CD-ROM "EXPRESSBUILDER" in the drive. 3. Execute "SETUP .EXE" which is in the "ESMPROenPCON" in CD-ROM from Explorer , and so on.
– 12 – 3. Management PC Setup This section explains Power Console Plus setup in a computer that manages servers via the network (TCP/IP). 3.1 OPERA TING ENVIRONMENT This section explains the operating environment re quired for Power Console Plus to operate on a management PC.
– 13 – 3.2 PREP ARA TIONS This section explains prerequisites for setup. TCP/IP setting for W indows must be completed. Updating of the system must be completed (when NEC Express server is used) The machine must be logged on by an Administrator group.
– 14 – 3.3 INST ALLA TION T ake the following steps to install Power Console Plus: 1. Power on the server to start W indows. 2. Set the provided CD-ROM labeled as "EXP RESSBUILDER" in the CD-ROM drive. 3. Run "SETUP .EXE" which is in the "ESMPROenPCON" in CD-ROM using Explorer , and so on.
– 15 – 5. Specify the directory to install the Power Console Plus, and click [Next]. Installation starts. When automatic setup comp letes, [Finish to Setup] screen appears. NOTE: T o change the installation directory , click on [Browse...] and specify the desired directory .
– 16 – 3.4 ENVIRONMENT SETUP Set up the environment as explained below . Setting HOSTS File Set the server information, management server in formation, and managem ent PC information of Power Console Plus into the HOSTS file that is provided/browsed by the TCP/IP of W indows.
– 17 – Modifying REGSERV.DAT File Modify management server inform ation regist ered in the REGSER V .DA T file that is provided/browsed by Power Console Plus. (The default host name registered is localhost.) Host name of the management server Use a text editor (e.
– 18 – 3.5 UNINST ALLING POWER CONSOLE PLUS T ake the following steps to uninstall Power Console Plus: 1. Power on the server and start W indows. 2. Set the provided CD-ROM "EXPRESSBUILDER" in the drive. 3. Execute "SETUP .EXE" which is in the "ESMPROenPCON" in CD-ROM from Explorer , and so on.
– 19 – 4. Features of Power Console Plus This section explains the features of Power Console Plus. The screen as shown below appears when Power Console Plus is started. Power Console Plus Screen Layout Element Description Menu Bar Select options from Configuration, Adapter , Physical Drv , Logical Drv , Progress, or Help m enus.
– 20 – 4.1 T OOLBAR ICONS Power Console Plus includes several toolbar icons at the top of the screen. These icons provide easy access to Power Console Plus feat ures. Display Configuration Icon Click on this icon to display the cu rrent RAID system configuration.
– 21 – Adapter Properties Icon Click on this icon to display the properties of the selected controller . Physical Drive Icon Click on this icon to display the properties of the selected physical drive.
– 22 – Logical Drive Icon Click on this icon to display the properties of the selected logical drive. Rebuild Rate Icon Click on this icon to change I/O ra te for rebuild or reconstruction.
– 23 – Display Log Icon Click on this icon to display the log as shown below . NOTE: Power Console Plus logs all events to Raid.log. Raid.log is created in the same directory where Power Console Plus runs.
– 24 – Help Icon Click on this icon to display info rm ation about Power Console Plus..
– 25 – 4.2 MENUBAR OPTIONS The Power Console Plus menus are: Option Description Configuration Choose this option to sta rt the Power Console Plus Wizard to co nfigure the RAID system. Adapter Choose this option to select controller-rel ated functions.
– 26 – Automatic Configuration : The W izard examines the system (e.g., connected physical drives and check mark on Redundancy checkbox) and automatically configures an optim al RAID system. Select [Automatic] and click on [Next]. The screen as shown below appears.
– 27 – Custom Configuration : Y ou can determine the configuration by specifying in detail the physical drives to be used and the logical drive to be created. Select [Custom], and click on [Next] . A screen as shown below appears. Select the drive to configure the array and clic k on [Add to Array].
– 28 – Display Choose this option to display the current RAID system configuration. Print Choose this option to print the current RAID system configuration. SA VE Choose this option to save the current RAID configuration to a hard disk or flopp y disk.
– 29 – Adapter Menu The options on the Adapter menu are described below . Option Description Remarks Update Firmware – This option is not available. Flush Cache Choose this option to force the controller to write the content s of cache memory to the logical drives.
– 30 – Option Description Remarks Alarm Control Choose this option to enable or disabl e the system alarm when the phy sical drive fails. Fast Initialization Choose this option to enable or disabl e Fast Initialization. Battery Status The battery information on a controller is displayed.
– 31 – Properties Choose this option to display the controller properties. Rebuild Rate Choose Rebuild Rate to select the amount of system resources to be devoted to rebuilding failed disk drives. Click on the slider to sel ect the percentage of system resources to devote to the disk rebuild and click [OK].
– 32 – V iew Log Select this option to display the MegaRAID event log. View NVRAM Event Log The log of NVRAM is displayed. View Bad Block Log The Bad Bloc k information o n a drive is dis played. Enclosure Management Displays the status of the RAID drive enclosures.
– 33 – Alarm Control The alarm generates a beeping sound when one or m ore physical disks fail. The sound continues until Silence Alarm is selected . After a rebuild finishes, a beep signals that the rebuild is done. Choose Silence Alarm at this time to silence the ala rm.
– 34 – Disable(Enable) Check Consistency Restoration It is set up whether the mismatching detected with the adjustment check is restored. Please do not change. Disable(Enable) Temp Offline RAID A T emp Offline function is set up.Please do not change.
– 35 – Physical Drive Menu Rebuild Choose the Rebuild option to rebuild one or m ore failed disk drives. Select [Abort Rebuild] to stop the rebuild process at any time. The drive will revert to its original status before the rebuild began. A RAID 1 or 5 configuration has redundancy .
– 36 – Property Choose this option to display the properties of the selected physical drive. If you select [Processor] to display properti es, the [Insertion] may be incorrectly displayed.
– 37 – Logical Drv Menu Initialize Choose this option to initialize the selected logical drive or drives. Y ou can view the progress of initialization. The time required fo r initialization depends on type and capacity of physical drive. IMPORT ANT : Power Console Plus allows y ou to initialize a drive at any time.
– 38 – Properties Choose [Properties] to display the properties of the selected logical drive. Each logical drive can be displayed by selecting the [Pre vious] or [Next] buttons. Indications on the screen may not be aligned, however , it will not af fect on other operation.
– 39 – Y ou can choose W rite Back or W rite Th ru. Write Policy Description Write Back The controller sends a dat a transfer completion si gnal to the host when the controller cach e has received all the data in a transaction.
– 40 – Progress Menu The features on this menu are available only when a rebuild, initialization, check consistency , or drive reconstruction are in progress. Option Description Rebuild Prog ress Displays th e progress of rebu ild process. Diagnostics Progress Displays t he progress of diagno stics test.
– 41 – 5. Running Power Console Plus This section describes how to run Power Console Plus. Described below is simple te rminology and basic operations. Drive Status The statuses of each physical drive shown to the right of the SCSI ID or array are as follows: Drive St atus Code Description Online Onln The physical drive works normally .
– 42 – Displaying Physical Drive Properties Double-click on the icon that represents the physical drive to display the properties of the selected physical drive as shown in the figure. Y ou can view the vendor and size of physical drive. Y ou can view the properties of each physical drive by clicking [Previous Drive] or [Next Drive] .
– 43 – 5.1 CONFIGURING ARRA YS AND LOGICAL DRIVES This section describes how to confi gure arrays and logical drives. Step 1 Choose W izard from the Configuration menu. The W izard screen appears. Choose [Custom] or [Automatic] mode and click on [Next] .
– 44 – Step 2 Select a physical drive in the Ready status. Click on [Add to Array] button to assign physical drives to the new array . Click on [Accept Array] button, and then click on [Next] button. NOTE: : Assign all phy sical disks used to configure a logical disk to [New Array ].
– 45 – Setting Advanced Parameter Set each parameter on the screen. NOTE: Some parameter values may be restricted to ensure the system performance and stable operation. Refer to the manual that comes with your controller . Step 4 V erify the array configuration on the screen.
– 46 – Step 5 Click on [OK] in the confirmation screen. The new configuration is saved in the controller . Step 6 Click on [OK] in the confirmation screen. Initializes the logical drive. NOTE: If you canceled, select the logical drive on [Logical Devices V iew] in main menu, sel ect [Initialize] in [Logical Drv] menu to initialize the drive.
– 47 – 5.2 REBUILDING PHYSICAL DRIVE This section describes how to rebuild the physical drive. Step 1 On [Physical Devices V i ew] in the main menu, select a physical drive you want to rebuild (icon representing physical drive being failed). Select [Rebuild] in Physical Drv menu.
– 48 – 5.3 CHECK CONSISTENCY ON LOGICAL DRIVE This section describes how to perform consistency check on logical drive. Step 1 Select an icon of logical drive to be checked in [Logical Devices V iew ] on main menu. Select [Check Consistency] in [Logical Drv] menu.
– 49 – 5.4 ONLINE CAP ACITY EXP ANSION This section describes the procedur es for online capacity expansion. Add Cap acity Y ou can add a physical drive to an existing array to expand capacity only under the following conditions: Only one logical drive is configured per array .
– 50 – Adding Cap acity using Power Console Plus On the main Power Console Plus screen, verify th at the drive(s) that are added displa y on the appropriate channel.
– 51 – The second method is: Ste p 1 On [Physical Devices V i ew] of the main menu, select the physical drive(s) you want to add, and on [Logical Devices V iew], select the logical drive to add them to. Right-click on the logical drive, and select [Add Drive] in Advanced menu.
– 52 – The third method is: Ste p 1 On [Physical Devices V i ew] of the main menu, select the physical drive(s) icon you want to add, and drag it to the logical drive icon you want to add them to. Ste p 2 A menu to select the RAID level is displayed.
– 53 – 6. Periodic Consistency Check Make a periodic consistency check on array disks and correct inconsistency detected. Doing so prevents a failure in rebuilding a failing physical drive. A consistency check must be made on the whole Read section of the logical drive.
– 54 – Argument Description arg1 -cons Sets a consistency check sche dule. Other arg parameters are us ed to set time. If no other arg parameters a re specified, relevant default is used. -h Sets the st art time of the consistency check. The time can be set in the range from 0 to 23.
– 55 – 7. Notes 1. The following event log is sometimes registered w hen uninst alling Pow er Console Plus. But there is no problem. Source: Service Control Manager Event ID: 7031 Description: The SNMP Service service terminat ed unexpectedly . It has done this 1 time(s).
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté NEC 5800 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du NEC 5800 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation NEC 5800, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le NEC 5800 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le NEC 5800, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du NEC 5800.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le NEC 5800. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei NEC 5800 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.