USER GUIDE AND SPECIFICATIONS NI USB-6008/6009 This user guide describes how to use the National Instruments USB-6008/6009 data acquisi tion (D A Q) de vices and lists specif ications.
NI USB-6008/6 009 User Gu id e and Specifications 2 ni.com Figure 1. NI USB-6008/6009 T op View Figure 2. NI USB-6008/6009 Back View Table 2. Differences Between the NI USB-6008 and NI USB-6009 Featur.
© National Instruments Corporation 3 NI US B-6008/600 9 User Gu ide and Specifications Dimensions Figure 3 illustrates the dimen sions of the NI USB-6008/6009 device. Figure 3. NI USB-6008/6009 in Mi llimeters (Inches) Safety Guidelines Caution Operate the NI USB-6008/600 9 only as describ ed in these oper ating instruct ions.
NI USB-6008/6 009 User Gu id e and Specifications 4 ni.com Do not operate the device in an e xpl osi ve atmosphere or where there may be flammable gases or fumes. If you must operate the device in such an en vir onment, it must be in a suitably rated enclosure.
© National Instruments Corporation 5 NI US B-6008/600 9 User Gu ide and Specifications • Measurement Category II is for m easurements performed on circuits directly connected to the electrical dist ribution system.
NI USB-6008/6 009 User Gu id e and Specifications 6 ni.com LabVIEW If you are a ne w user , use the Getting Started wit h LabVIEW manual to familiarize yourself with the LabVIEW graphical program ming en vironm ent and the basic LabVIEW features you use to build data acquisition and instrum ent control applications.
© National Instruments Corporation 7 NI US B-6008/600 9 User Gu ide and Specifications based on your task or channel in Measurement Studio. Refer to the DAQ Assistant Help for additional info rmation about ge nerating code. Y ou also can create channels and tasks, and write your own applications in your ADE using the NI-D A Qmx API.
NI USB-6008/6 009 User Gu id e and Specifications 8 ni.com Library»Reference to vie w th e function reference. Expand NI Measureme nt Studio Help»NI Measuremen t Studio .NET Class Library»Using the Measurement Studio .NET Class Libraries to view conceptual topics for using NI-D AQmx with V isual C# and Vi s u a l B a s i c .
© National Instruments Corporation 9 NI US B-6008/600 9 User Gu ide and Specifications Note All NI-D A Qmx Base documentation for Linux is install ed at /usr/local/natinst/nidaqmxbase/docum entation . Note All NI-D A Qmx Base documentat ion for Mac OS X is installed at /Applications/National Instruments/N I-DAQmx Base/documentation .
NI USB-6008/6 009 User Gu id e and Specifications 10 ni.com Note For information about non-Wi ndows operating system support, refer to ni.com/ info and enter BaseGSGML . Installing the NI USB-6008/6009 Device Before installing the device, you must install the software you plan to use with the device.
© National Instruments Corporation 11 NI US B-6008/6 009 User Gu ide and Specifications Setting Up the NI USB-6008/6009 Device Complete the following steps to set up the NI USB-6008/ 6009: 1. Install combicon scr ew terminal blocks by inserting them into the combicon jacks.
NI USB-6008/6 009 User Gu id e and Specifications 12 ni.com Figure 6. Signal Label Application Diagram Note Once you label the screw terminal blocks, you must only insert them into the matching combicon jack , as indicated by the ov erlay label on the NI USB-6008/6009 device.
© National Instruments Corporation 13 NI US B-6008/6 009 User Gu ide and Specifications Connecting the NI USB- 6008/6009 to a Computer Plug one end of the USB cable into the NI USB-6008/6009 and the other end into an available USB port on the computer.
NI USB-6008/6 009 User Gu id e and Specifications 14 ni.com I/O Connector The NI USB-6008/6009 ship s with one detachable screw terminal block for analog signals and one detachable scre w terminal block for digital signals. These terminal blocks provide 16 connect ions that use 16 A WG to 28 AWG wire.
© National Instruments Corporation 15 NI US B-6008/6 009 User Gu ide and Specifications Table 5. Digital T erminal Assignments Module T erminal Signal 17 P0.0 18 P0.1 19 P0.2 20 P0.3 21 P0.4 22 P0.5 23 P0 6 24 P0.7 25 P1.0 26 P1 .1 27 P1.2 28 P1.3 29 PFI 0 30 +2.
NI USB-6008/6 009 User Gu id e and Specifications 16 ni.com Signal Descriptions Table 6 describes the signals available on the I/O connectors. Table 6.
© National Instruments Corporation 17 NI US B-6008/6 009 User Gu ide and Specifications Analog Input You can connect analog input signals to the NI USB-6008 /6009 through the I/O connector. Refer to Table 6 for more informat ion about connecting analog input signals.
NI USB-6008/6 009 User Gu id e and Specifications 18 ni.com AI FIFO The NI USB-6008/6009 can perform both si ngle and multiple A/D conversions of a fixed o r infinite num ber of samples. A fir st-in-first-ou t (FIFO) buffer holds data during AI acquisitions to ensure that no data is lost.
© National Instruments Corporation 19 NI US B-6008/6 009 User Gu ide and Specifications Figure 9. Example of a Differential 20 V Measurement Connecting a signal greater than ±10 V on either pin results in a clipped output.
NI USB-6008/6 009 User Gu id e and Specifications 20 ni.com Figure 11. Co nnecting a Reference Si ngle-Ended V oltage Signal Digital T rigger When an AI task is defi n ed, you can configure PFI 0 as a digital trigger input.
© National Instruments Corporation 21 NI US B-6008/6 009 User Gu ide and Specifications DACs Digital-to-analog convert s (DACs) convert digital codes to analog voltages.
NI USB-6008/6 009 User Gu id e and Specifications 22 ni.com Digital I/O Circuitry Figure 14 shows P0.<0..7> conn ected to example signals configured as digital inputs and digital outputs.
© National Instruments Corporation 23 NI US B-6008/6 009 User Gu ide and Specifications Figure 15. Example of Connecting an Exte rnal User -Provided Resistor Complete the following steps to determine the v alue of the user-provided pull-up resistor: 1.
NI USB-6008/6 009 User Gu id e and Specifications 24 ni.com I/O Protection To protect the NI USB-6008/6009 ag ainst overvol tage, undervoltage, and overcurrent conditions, as well as ESD events, you s.
© National Instruments Corporation 25 NI US B-6008/6 009 User Gu ide and Specifications Reference and Power Sources The NI USB-6008/6009 creates an external reference and suppl ies a power source. All voltages are relative to COM unless otherw ise noted.
NI USB-6008/6 009 User Gu id e and Specifications 26 ni.com Timing accuracy ........ .............. ............... 1 00 ppm of actual sample rate Input range Single-ended . ............... ................ ....±10 V Differential ............ .......
© National Instruments Corporation 27 NI US B-6008/6 009 User Gu ide and Specifications Analog Output Analog outputs ..................... .............. .... 2 Output resolution..................... .............. . 12 bits Maximum update rate .....
NI USB-6008/6 009 User Gu id e and Specifications 28 ni.com Compatibility ............. .............. .............. .TTL, LVTTL, CMOS Absolute maximum voltage range ..........– 0.5 to 5.8 V with respect to GND Pull-up resistor ....................
© National Instruments Corporation 29 NI US B-6008/6 009 User Gu ide and Specifications Minimum low pulse width ..................... 100 ns Input high voltage ................... .............. . 2.0 V Input low voltage ...... .............. .......
NI USB-6008/6 009 User Gu id e and Specifications 30 ni.com Safety If you need to clean the module, wipe it with a dry towel. Safety Vo ltages Connect only voltages that are within these limits.
© National Instruments Corporation 31 NI US B-6008/6 009 User Gu ide and Specifications Maximum altitude ........... .............. ......... 2,000 m (at 25 °C ambient temperature) Storage temperature (IEC 60068-2-1 and IEC 60068-2-2) ..... – 40 to 85 °C Storage humidity (IEC 60068-2-56) .
National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for mor e informat ion about Nationa l Instruments trademarks. Other product and compan y names mentioned herein are trademarks or trade names of their respective companie s.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté National Instruments NI USB-6009 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du National Instruments NI USB-6009 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation National Instruments NI USB-6009, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le National Instruments NI USB-6009 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le National Instruments NI USB-6009, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du National Instruments NI USB-6009.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le National Instruments NI USB-6009. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei National Instruments NI USB-6009 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.