INSTALLATION GUIDE NI TB-2709 PXI T erminal Block for S Seri es Devices This installation guide des cribes how to install and connect sig nals to the NI TB-2 709 terminal block for use wi th PXI-6123 /6133 S S eries devi ces. The TB-2709 can also be used with the PXI-6 122/6132 devices to acces s the first four AI channels.
NI TB-2709 I nstallation Guide 2 ni.com The nine SMB con nectors on the TB-2709 allow yo u to easily conn ect analog in put signals to your National I nstruments de vice. The 14 -pin I/O connector located on the bottom of the TB-2709 allo ws access to digital signals .
© Natio nal Instrum ent s Corpora tion 3 NI TB-2709 Inst alla tion Guide Do not substitute parts or modify equipment. Because of the danger of introducing additional hazards, d o not install unauthor ized parts or modify the device.
NI TB-2709 I nstallation Guide 4 ni.com T o conn ect the terminal block to the PXI module I/O connector , refer to Figure 2 as you complete the following steps: 1. Install the PXI module into the chass is and tighten the two module scre ws. Y ou must ins tall the PXI de vice before co nnecting the TB-2709.
© Natio nal Instrum ent s Corpora tion 5 NI TB-2709 Inst alla tion Guide Figu re 4. NI TB -2709 B lock Dia gram For more detailed descriptions of these signals, refer to the S Series User Manual . Addit ion al s ign al co nfigur ati on in for m ation is av ailable in Measurement & Automation Explor er (MAX).
NI TB-2709 I nstallation Guide 6 ni.com Measuring Gro und-R eferenced Signa ls It is possible to set the switch on th e TB-2709 to either the floating or ground-referenced source position to measu re ground-referenced signals. However, for b est re sults, use th e OFF (grou nd-referenced source) switch posi tion t o avo id gr ound loop s.
© Natio nal Instrum ent s Corpora tion 7 NI TB-2709 Inst alla tion Guide conductors on the other end. The pigtail conductor s on the cable assembly can be us ed to terminate dig ital signal s to the connector(s) your application requires.
NI TB-2709 I nstallation Guide 8 ni.com T able 4 lists the National Instrum ents cables av ai lable for connecting the TB-2709 to both analog and dig ital user signals. Specificatio ns This section lists the specificati ons of the TB -2709. Thes e specifications are typical at 25 °C unless otherwise specified.
© Natio nal Instrum ent s Corpora tion 9 NI TB-2709 Inst alla tion Guide Physical Dimensions Height............... ................. ........... ... 10.7 × 8. 6 × 2.0 cm (4.2 × 3.4 × 0.8 in.) Weight .............. ................. ........... ..
NI TB-2709 I nstallation Guide 10 ni.com Safe ty This product is designed to meet the req uirements of the following standards of safety for electrical equ ipment for measurement, contr ol, and labora.
© Natio nal Instrum ent s Corporati on 11 NI TB-2709 In stalla tion Gui de Finland 385 (0) 9 725 72511, Fr ance 33 (0) 1 48 14 24 24, German y 49 89 7 413130, I ndia 91 8 0 4119000 0, Israel 9 72 3 6.
National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments C orporation. Refer to the Terms of Use section on ni.com/legal for more informa tion about N ational Instruments trademarks. Other product and company names ment ioned herein are trademarks or tr ade names of their respect ive companies.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté National Instruments NI TB-2709 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du National Instruments NI TB-2709 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation National Instruments NI TB-2709, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le National Instruments NI TB-2709 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le National Instruments NI TB-2709, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du National Instruments NI TB-2709.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le National Instruments NI TB-2709. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei National Instruments NI TB-2709 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.