USER GUIDE SCC-AO10 Isolated Analog Output Module The SCC-AO10 is an isolated voltage output module wit h an output range of ±10 V. The output voltage level is controlled by the DA C output of an E/M Series DAQ device. You can incr ease the output voltage level to ±20 V by connect ing two SCC-AO 10 modules in series.
SCC-AO10 Isolated Analog Output Module Use r Guide 2 ni.com monospace T e xt in this font denotes text or ch aracters that you should enter from the keyboard, sections of code, programming examples, and syntax examples.
© National Instruments Corpor ation 3 SCC-AO10 Isolated Analog Output Mo dule U ser Guide Note Software scaling of measurements is not supported on the Macintosh operating system. Refer to the SCC-AO10 Connector Pin Assignments section. Y ou can do wnload NI documents from ni.
SCC-AO10 Isolated Analog Output Module Use r Guide 4 ni.com Figures 1 and 2 show the SCC-A O10 c onnected to a nonreferenced load and to a load w ith a hi gh common-mode voltage.
© National Instruments Corpor ation 5 SCC-AO10 Isolated Analog Output Mo dule U ser Guide Figure 3. Connecting T wo SCC-AO10 Modules in Series The SC-2345/2350 routes the E/M Series D A Q device analog output channels A O 0 and A O 1 to the SCC-A O10 modules, and the resu lting maximum output voltage range is ±20 V .
SCC-AO10 Isolated Analog Output Module Use r Guide 6 ni.com Using the SCC-AO10 This section contains information regarding scali ng voltage measurements and isolated ground references. Scaling V oltage Measurements The SCC-AO10 is a ±10 V isolated analog output module.
© National Instruments Corpor ation 7 SCC-AO10 Isolated Analog Output Mo dule U ser Guide 5. Adjust the offset potentiometer on the top of the SCC-A O10 unt il the voltmeter reads 0 VDC ±100 μ V . The of fset is no w calibrated. 6. Using your software, hav e A O ( X ) output 9.
SCC-AO10 Isolated Analog Output Module Use r Guide 8 ni.com Power Requirement Analog power ............... ................. .........180 mW max at full load 172 mW max w ith no load + 15 V .... ................. .............. ............6 mA max at full load 5.
© National Instruments Corpor ation 9 SCC-AO10 Isolated Analog Output Mo dule U ser Guide Maximum W orking Voltage (Signal + common- mode) each input should remain within 42.4 V peak or 60 VDC of ground. Maximum working voltage refers to the signal voltage plus the CMV .
SCC-AO10 Isolated Analog Out put Module Use r Guide 10 ni.com Safety This product meets the requirements of the follow ing standards of safety for electrical equipment for measurement, contro l, and l.
© National Instruments Corpor ation 11 SCC-AO10 Isolat ed Analog Output Module User Guide Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible man ner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.
National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for mor e information a bout National Instruments trademarks. Other product and compan y names mentioned herein are trademarks or trad e names of their respective companie s.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté National Instruments Isolated Analog Output Module SCC-AO10 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du National Instruments Isolated Analog Output Module SCC-AO10 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation National Instruments Isolated Analog Output Module SCC-AO10, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le National Instruments Isolated Analog Output Module SCC-AO10 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le National Instruments Isolated Analog Output Module SCC-AO10, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du National Instruments Isolated Analog Output Module SCC-AO10.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le National Instruments Isolated Analog Output Module SCC-AO10. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei National Instruments Isolated Analog Output Module SCC-AO10 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.