Manuel d'utilisation / d'entretien du produit GDIZC-N du fabricant Napoleon Fireplaces
Aller à la page of 16
1 W415-0223 / E / 03.05.09 W olf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada t (705)721-1212 t fax (705) 722-6031 www .napoleonreplaces.com t ask@napoleon.on.ca INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
2 W415-0223 / E / 03.05.09 Pg 2-4 INTRODUCTION W arranty General Instructions General Information Care of Glass & Plated Parts 5-7 INST ALLA TION Insert V ent Connection Chimney Connection W all S.
3 W415-0223 / E / 03.05.09 NAPOLEON gas fi replaces are manufactured under the strict Standard of the world recognized ISO 9001:2000 Quality Assurance Certi fi cate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0223 / E / 03.05.09 FOR YOUR SA TISF ACTION, THIS FIREPLACE INSERT HAS BEEN TEST -FIRED TO ASSURE ITS OPERA TION AND QUALITY! Minimum inlet gas supply pressure is 4.5 inches water col- umn for natural gas and 1 1 inches water column for propane.
5 W415-0223 / E / 03.05.09 36" 15 1 / 2 " 25" 10 9 / 16 " 5 ½" AIR INLET EXHAUST 4 15 / 16 " 15 1 / 2 " 11 5 / 8 " 7 3 / 8 " 3"Ø 44 7 / 8 " 3 SIDED BACKER PLATE ALUMINUM TRIM 44 7 / 8 " 36 1 / 2 " 4 SIDED BACKER PLATE ALUMINUM TRIM Provide adequate ventilation air .
6 W415-0223 / E / 03.05.09 2" OVERLAP EXHAUST SEALANT HI-TEMP INTAKE VENT CONNECTION ASSEMBLY Move the insert close to its fi nal position inside the wood- burning fi replace.
7 W415-0223 / E / 03.05.09 For ease of accessibility , an optional remote wall switch or millivolt thermostat may be installed in a convenient location. Route 2-strand solid core millivolt wire from the gas fi replace insert to the wall switch / millivolt thermostat.
8 W415-0223 / E / 03.05.09 Positioning the logs improperly will cause fl ame impingement and carboning. PHAZER TM logs and glowing embers, exclusive to Napoleon Fireplaces, glow when exposed to direct fl ame and provide a unique and realistic glowing effect that is dif ferent in every installation.
9 W415-0223 / E / 03.05.09 The on-off switch is located behind the left side control door . Purge all gas lines with the glass door open. Assure that a continuous gas fl ow is at the burner before closing the door . Allow several minutes (5-15) for the fl ame to stabilize after ignition.
10 W415-0223 / E / 03.05.09 1. Turn of f the electrical power and the gas supply to the fi replace insert. 2. Remove the fi re viewing door . Remove the logs. 3. Detach the two screws from the back of the fi rebox and remove the panel, as illustrated.
11 W415-0223 / E / 03.05.09 A mirror will let you see the opening of the air shutter without removing the burner . Scribe a line along the venturi tube and air shutter cap. Open or close according to the original opening by us- ing the scribed line as your datum.
12 W415-0223 / E / 03.05.09 31* W690-0001 MILLIVOL T THERMOST A T 32* W660-0010 REMOTE CONTROL - ADV ANT AGE 32* W660-001 1 REMOTE CONTROL - ADV ANTAGE PLUS 33* GD660 REMOTE W ALL SWITCH C / W 20FT WI.
13 W415-0223 / E / 03.05.09 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.
14 W415-0223 / E / 03.05.09 PILOT BURNER THERMOCOUPLE THERMOPILE Main burner goes out; pilot stays on. Pilot fl ame is not large enough or not engul fi ng the thermopile. Thermopile shorting Remote wall switch wire is too long, too much resistance in the system Faulty thermostat or switch - turn up pilot fl ame.
15 W415-0223 / E / 03.05.09 Exhaust fumes smelled in room, headaches. - check all seals. Fireplace is spilling. Carbon is being de- posited on glass, logs or combustion cham- ber surfaces. Flame is impinging on the logs or combustion chamber . - check that the logs are correctly positioned.
16 W415-0223 / E / 03.05.09 Appliance Ser vice Histor y This heater must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Dealer Name 43.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Napoleon Fireplaces GDIZC-N c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Napoleon Fireplaces GDIZC-N - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Napoleon Fireplaces GDIZC-N, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Napoleon Fireplaces GDIZC-N va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Napoleon Fireplaces GDIZC-N, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Napoleon Fireplaces GDIZC-N.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Napoleon Fireplaces GDIZC-N. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Napoleon Fireplaces GDIZC-N ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.