Manuel d'utilisation / d'entretien du produit EDS-828 du fabricant Moxa Technologies
Aller à la page of 16
Moxa EtherDevice Switch EDS-728/828 Hardware Installation Guide First Edition, January 2008 Moxa Inc. Tel: +886-2- 8919-1230 Fax: +886-2-89 19-1231 www.
1 Panel Layout of EDS-728/828 Series COUPLER MODE RING PORT COUPLER PORT FDX/HDX STAT PWR1 FAULT MASTER PWR2 LNK/ACT SPEED IM-4MSC TX RX 3 4 TX RX 1 2 PWR P3 P1 P4 P2 IM-4MST TX RX 3 4 TX RX 1 2 PWR P3 P1 P4 P2 34 IM-4TX 12 PWR P3 P1 P4 P2 RS-232 Console T .
2 13 13 14 15 15 13 16 1. System status LEDs 2. Push-button switch to select mode for Interface Module 3. Interface Module mode LEDs 4. Fast Ethernet Interface Module port LEDs 5. Terminal block for 2 power inputs, 2 DIs, and 2 DOs 6. Sticker showing pin contacts 7.
3 Mounting Dimensions (unit = mm) 381.70 30 85.00 142.47 Front View EtherDevice Switch 80.6 201.2 362.40 401.00 Rear View 128.00 142.47 140.00 Side View Gigabit Ethernet Interface Modules Front View Side View 101.1 65.9 24 Fast Ethernet Interface Modules 40 127.
4 DIN-Rail Mounting The DIN-Rail attachment plates are per m anently fixed to the back panel of the EDS-728/828. Do not attempt to rem ove the attachment plates, since doing so could damage the product .
5 STEP 2 : Mounting the EDS-728/828 on the wall requir es 4 screws to ensure that the switch does not come loose from the wall. Use the switch, with wall mounting plates attached, as a guide to mark the correct locations of the 4 screws. The heads of the screws should be less than 6.
6 Wiring Requirements WARNING Saf ety Fi rst! Be sure to disconnect the power cord before installing and/or wiring your M oxa EDS-728/828. Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes dictating the maximum current allowable for each wire size.
7 RELA Y1 RELA Y2 PWR1 PWR2 V2+ V2- V1+ V1- D I 1 I 1 I 2 D I 2 T op View Front View FA ULT : The two sets of relay contacts of the 6-pin terminal block connector are used to detect user-configured events. The two wires attached to the Fault contacts form an open circuit when a user-configured event is triggered.
8 Communication Connections The pinout and cable wiring diagrams in this section show how the ports on the EDS-728/828 connect to other devices: Pinouts are diagrams that indicate the ty pe of signal passing through each of the port’s pins.
9 MDI/MDI-X Port Pinouts Pin Signal 1 TRD(0)+ 2 TRD(0)- 3 TRD(1)+ 4 TRD(2)+ 5 TRD(2)- 6 TRD(1)- 7 TRD(3)+ 8 TRD(3)- 1 8 100/1000Base Fiber Port Connection The concept behind the duplex port and cable is quite straightforward. Suppose you are connecting devices I and II.
10 On This EDS-728/828 is the Master of this Turbo Ring. Blinking This EDS-728/828 has become Ring Master of this Turbo Ring after the Turbo Ring was broken. MASTER GREEN Off This EDS-728/828 is not the M aster of this Turbo Ring. On When this EDS-728/828 enables the coupling function to form a back- up path.
11 Fast Ethernet Module LEDs On Power is being supplied to the interface module. PWR GREEN Off Power is not being supplied to the interface module. P1/P2/ P3/P4 GREEN On/ Off/ Blinking Displays the module port’s status by mode. Gigabit Ethernet Module LED P1/P2 GREEN On/ Off/ Blinking Displays the module port’s status by mode.
12 Digital Inputs Two inputs with the same ground, but electrically isolated from the electronics. x For state “1”: +13 to +30V x For state “0”: -30 to +3V x Max. input current: 8 m A Power Input Voltage 24 VDC (12 to 45 VDC), redundant dual inputs Connection Two removable 6-pin terminal blocks Power Consumption EDS-72810G/82810G 22.
13 Optical Fiber/SFP-1GxxxLC Series SX LX LHX ZX Wavelength 850 nm 1310 nm 1310 nm 1310 nm Max. Tx -4 dBm -3 dB m 1 dBm +5 dBm Min. Tx -9.5 dBm -9.5 dBm -4 dBm 0 dBm Rx Sensitivity -18 dBm -20 dBm -24 dBm -24 dBm Link Budget 8.
14 IM-2MSC/2TX: Interface Module with 2 multi mode 100BaseFX ports, SC connectors, and 2 10/100BaseT(X) ports, RJ45 connector s. IM-2MST/2TX: Interface Module with 2 multi mode 100BaseFX ports, ST connectors, and 2 10/100BaseT(X) ports, RJ45 connector s.
15 IM-2MST /2TX 250 g IM-2SSC/2TX 245 g IM-1LSC/3TX 235 g IM-4MSC 250 g IM-4MST 270 g IM-4SSC 270 g Environmental Operating Temperature 0 to 60°C (32 to 140°F) Storage Temperature -40 to 85°C (-40 to 185°F) Ambient Relative Humidity 5 to 95% (non-condensing) Regulatory Approvals Safety UL60950-1, CSA C22.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Moxa Technologies EDS-828 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Moxa Technologies EDS-828 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Moxa Technologies EDS-828, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Moxa Technologies EDS-828 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Moxa Technologies EDS-828, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Moxa Technologies EDS-828.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Moxa Technologies EDS-828. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Moxa Technologies EDS-828 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.