Manuel d'utilisation / d'entretien du produit C168HS du fabricant Moxa Technologies
Aller à la page of 102
Sm ar ti o C168H/HS User ’s Manual Universal 8 Port Serial Board May 1999 (6th Edition) The content of this manual is also available in CD-ROM and at Moxa Web Site. Moxa Technologies Co., Ltd. Tel: +866-2-8665-6373 Fax: +886-2-8665-6372 www.moxa.com support@moxa.
Sm ar t io C168H/HS User ’s Manual The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of the agreements. Copyright Notice Copyright 1999 Moxa Technologies Co., Ltd. All rights reserved.
MOXA Internet Services Customer’s satisfaction is always our number one concern. To ensure that customers get the full benefit of our services, Moxa Internet Services have been built for technical support, product inquiry, new driver update, user’s manual update, etc.
About This Manual This manual is composed of six Chapters and one A ppendix. This manual is written for installer, system administrator and software programmer. If you are a first-time installer and system administrator, we recommend you to go through the whole manual except Chapter 4.
Table of Contents Introduction ..................................................................... 1-1 Overview ................................ ................................ ................................ ................ 1-1 Features.........
Setting MOXA Ports to Terminal ................................ ................................ .................. 3-35 Serial Programming Tools ................................................ 4-1 Windows NT and Windows 95/98 .......................
Smartio C168H/HS User ’s Manual 1-1 1 1 1 In tro duc tion Overview S ma rt i o - The Smart Multiport Async Solutions The term Smartio stands for smart multiport serial I/O solution.
1-2 Smartio C168H/HS User ’s Manual Hardware Configuration Method S m a rt io F a mil y J P 1 T r a d it io n a l M u lt i p o o r t B o a rd J u m p e r ON 1 2 3 4 S w it c h .. . .. .. . . .. . .. .. . . New : set I/O address Traditional : set switch and and IRQ via software and jumper manually for Utility.
Introduction Smartio C168H/HS User ’s Manual 1-3 Surge Protection To prevent the boards from damage caused by lighting or high potential voltage, surge protection technology is introduced in some model to protect the board.
1-4 Smartio C168H/HS User ’s Manual Features The Smartio C168 Series consist of members as follows, C168H 8 port RS-232 or RS-422, high speed 16550C or compatible UART C168HS 8 port RS-232 or RS-422.
Introduction Smartio C168H/HS User ’s Manual 1-5 Check List Upon unpacking the Smartio C168 Series package, you should find the following items in the package, v Smartio C168 Series 8-port high perf.
1-6 Smartio C168H/HS User ’s Manual Opt8C/Opt8D v RS-232 octopus cable with 8 port male connectors, DB25 for Opt8C and DB9 for Opt8D (1 meter long). P1 P2 P3 P4 P6 P5 P7 P8 Opt 8C/Opt8D Smar tio C168 Series Opt8F/Opt8Z v RS-422 connection box with 8 port female DB25 connectors (isolation protection for Opt8F).
Introduction Smartio C168H/HS User ’s Manual 1-7 Opt8J v RS-422/485 connection box with 8 port female DB25 connectors. v 1.5 meter DB62 to DB62 cable.
1-8 Smartio C168H/HS User ’s Manual RS-485 Mode The Opt8J supports only 2-wire RS-485 communication. Set the respective switch to ON position to use RS-485 interface. This means the port can transmit data only when RTS is asserted, and receive data only when RTS is not asserted (half-duplex).
Smartio C168H/HS User ’s Manual 2-1 2 2 2 Hard war e In s t allat ion The installation of the Smartio C168 Series consists of hardware and software installation. The hardware installation is detailed in this chapter. The next chapter deals with the software installation for various operating systems.
2-2 Smartio C168H/HS User ’s Manual Now you should do either the normal hardware installation (detailed in the later section, “Hardware Installation with IO-IRQ Utility”) or the quick hardware installation (detailed right in the next section, “Quick Hardware Installation”).
Hardware Installation Smartio C168H/HS User ’s Manual 2-3 software configuration program will automatically update the hardware settings. After this, users already complete the whole installation. 4. Shutdown System (Windows NT/95/98). 5. DO power OFF and then ON (or Reset) the PC.
2-4 Smartio C168H/HS User ’s Manual Because the ASIC-designed Smartio C168 Series has no switch and no jumper for configuring manually the I/O address, IRQ, INT vector, etc. of the boards, you must run the software utility, Io-irq.exe , in the driver diskette under DOS system to change the hardware configuration.
Hardware Installation Smartio C168H/HS User ’s Manual 2-5 typed correctly. With the correct CAP address, the utility can find the configuration stored in the on-board EEPROM and display it on the configuration panel. The CAP address is the only channel via which the configuration utility Io-irq.
2-6 Smartio C168H/HS User ’s Manual 3. Enter the CAP address of the Smartio C168 Series board to be configured. 4. Configure the following parameters as necessary. Port Index Indicate the port index for each port. I/O address Enter the base I/O address for each port, either sequentially or not.
Hardware Installation Smartio C168H/HS User ’s Manual 2-7 Note that, currently, port that uses MOXA Windows NT and 95/98 driver will run at the displayed speed. To be clear, when Smartio C168 Series board is configured as High Speed Spectrum , any port driven by the Moxa-provided Windows NT and 95/98 driver will display the exact working speed.
2-8 Smartio C168H/HS User ’s Manual Normal Speed Spectrum High Speed Spectrum 50 (bps) 400 (bps) 75 600 110 880 134.5 1076 150 1200 300 2400 600 4800 1200 9600 1800 14.4K 2400 19.2K 4800 38.4K 7200 57.6K 9600 76.8K 19.2K 153.6K 38.4K 307.2K 57.6K 460.
Smartio C168H/HS User ’s Manual 3-1 3 3 3 So ft wa r e I n sta lla ti on In this chapter, the software driver installation, configuration and driver update/removal procedures are described for vario.
3-2 Smartio C168H/HS User ’s Manual Installing Driver Following is the procedure for installing the Smartio C168 Series driver for the first time under Windows NT 4.0. Note ! Make sure the board(s) has(have) already been plugged in the system slot(s) if you are doing quick installation.
Software Installation Smartio C168H/HS User ’s Manual 3-3 5. Select “ MOXA Smartio/Industio Family multiport board ” in the “Select OEM Option” dialog box, and then click [ OK ] to enter the “ Moxa Smartio/Industio Configuration Panel ” dialog box to start the installation.
3-4 Smartio C168H/HS User ’s Manual Note ! You may go directly to the step 8 if you need not change any setting. 7. In the “ Property ” dialog box, select the desired port in the port list and click [ Port Setting ] to enter the individual “ Port # ” setting dialog box to change the port COM number mappings or FIFO settings.
Software Installation Smartio C168H/HS User ’s Manual 3-5 l Port Number You have to set up all the ports of the board with the desired “ COM number ”, which should not conflict with other COM number in use.
3-6 Smartio C168H/HS User ’s Manual 9. When configuration is done, click on [ OK ] button in the “Network Settings” dialog box. 10. Restart Windows NT system. The latest configuration will not take effect unless the system restarts. Note ! The latest configuration will not take effect unless the system restarts.
Software Installation Smartio C168H/HS User ’s Manual 3-7 Note ! Once the board and the driver are installed and the driver restarts successfully, you can start to develop applications with the PC o m m library (See “Serial Programming Tools” chapter) or the Microsoft Win32 API.
3-8 Smartio C168H/HS User ’s Manual 3. Click on the [ Property ] button to open the “Moxa Smartio/ Industio Configuration Panel” dialog box. Please see steps 6-10 in the previous section, “Installing Driver”, for more details.
Software Installation Smartio C168H/HS User ’s Manual 3-9 Updating Driver To update the driver for the Smartio C168 S er i e s boards, simply remove the driver, as described in the next section, and reinstall it as detailed in section, “Installing Driver” .
3-10 Smartio C168H/HS User ’s Manual Installing Driver Up to four Smartio C168 Series boards can be installed together as long as the I/O addresses and IRQ number resources are sufficient and available in a system. The following is the procedure for installing Smartio C168 Series for the first time under Windows 95/98: 1.
Software Installation Smartio C168H/HS User ’s Manual 3-11 Note ! Go directly to the step 7 if you need not change any setting. 6. In the “ Property ” dialog box, select the desired port in the .
3-12 Smartio C168H/HS User ’s Manual l Port Number You have to set up all the ports of the board with the desired “ COM number ”, which should not conflict with other COM number in use.
Software Installation Smartio C168H/HS User ’s Manual 3-13 8. Restart Windows 95/98 system . Note ! The latest configuration will not take effect unless the system restarts. 9. When system restarts, all the error conditions of the board will be popped up onto the screen if any.
3-14 Smartio C168H/HS User ’s Manual Configuring Board and Port If you already have installed the driver and want to re-configure the Smartio C168 Series board and ports, add more boards or delete boards under Windows 95/98, the following is the procedure for you.
Software Installation Smartio C168H/HS User ’s Manual 3-15 Updating Driver Open [ Control Panel ] icon, and then [ System ] icon, and then select [ Device Manager ] tab. Then select and open the “MOXA Smartio/ Industio Multiport Board” option and then select the “ C168 Series ”.
3-16 Smartio C168H/HS User ’s Manual Removing Driver Open [ Control Panel ] icon, and then [ Add/Remove Programs ] icon, and then select [ Install/Uninstall ] tab. Then select and open the “MOXA Smartio/Industio Driver” option and then enter [ OK ] to remove the driver.
Software Installation Smartio C168H/HS User ’s Manual 3-17 DOS MOXA DOS API-232 is a software package that assists users to develop and/or debug programs for serial communications. This section will show you how to install the package, how to setup up the driver, and how to load or unload driver.
3-18 Smartio C168H/HS User ’s Manual After installation is complete, you will be prompted to proceed running setup program. It is strongly recommended to do so.
Software Installation Smartio C168H/HS User ’s Manual 3-19 2. Press Enter to pop up the SETUP dialog box. In the SETUP dialog box, Press F8 to specify the CAP Address and press ENTER and then type Y ( YES ) to load the configuration of the board to be setup.
3-20 Smartio C168H/HS User ’s Manual 3. Now the configuration of the desired Smartio C168 Series board will be shown along with other default settings, such as port number, buffer size, etc. Note ! Up to now you have completed the setup for Smartio C168 Series board.
Software Installation Smartio C168H/HS User ’s Manual 3-21 You may now enter/modify each port’s configuration. These displayed values are the port initial values as driver is loaded. Legend : Some noticeable fields and functions are explained below.
3-22 Smartio C168H/HS User ’s Manual F6: INT vector: This is to set interrupt vector for each port. You can set this feature to “ Yes ” (default) and gain best performance for the board. 4. Press F10 to save the latest configuration and exit the SETUP program.
Software Installation Smartio C168H/HS User ’s Manual 3-23 If something went wrong, for instance, the board does not match the configuration or the board is missing, the screen will show a message like: API-232 Version 3.
3-24 Smartio C168H/HS User ’s Manual Installing Driver Th e fo ll ow in g de sc rip ti on i s fo r S ma rti o C1 68 S er ie s u nd er S CO U NI X/ Op enS er ve r and UNIX SVR4.2. Step 1. Login the UNIX system as a super user (root). Step 2. Change to root directory.
Software Installation Smartio C168H/HS User ’s Manual 3-25 Please select one of the following OSs: 1. SCO UNIX 2. UNIX SVR4.2 Select : Please select one of the devices where the driver diskette/files put: 1. /dev/fd0135ds18 (A: 1.44MB ) 2. /dev/fd096ds15 (A: 1.
3-26 Smartio C168H/HS User ’s Manual Step 7. Now you may shutdown the system and reboot. If you have trouble in booting the new UNIX kernel, use the backup kernel ( /unix.moxa or /stand/unix.moxa ) to boot your system and the system will work as before.
Software Installation Smartio C168H/HS User ’s Manual 3-27 MOXA TTY Device Naming Convention If the Smartio C168 Series is successfully configured, there will be two tty devices created for each port at /dev directory: one is non-MODEM tty (e.g. ttye11), and the other is MODEM tty (e.
3-28 Smartio C168H/HS User ’s Manual Baud Rate Settings For Smartio C168 Series set to High Speed Spectrum , the real working speed, is exactly eight times of the speed displayed by “ stty” command. A port, if set to Normal Speed Spectrum with 38.
Software Installation Smartio C168H/HS User ’s Manual 3-29 Basic Configuration In the [Basic configuration] dialog, users can set base I/O address and interrupt, which should be the same as the hardware configuration of the boards. Kernel rebuilding is required if any setting is changed.
3-30 Smartio C168H/HS User ’s Manual others it may stand for 7-data-bit, even-parity. So, please examine the “getty default” file carefully, and make sure the terminal settings is the same.
Software Installation Smartio C168H/HS User ’s Manual 3-31 Label High/Normal Speed Normal Speed High Speed Low Band High Band High Band B50 50 57600 57600 B75 75 115200 115200 B110 110 110 230400 B1.
3-32 Smartio C168H/HS User ’s Manual Tx FIFO Trigger Tx FIFO sizes from 1 to 16 bytes are available, and the default value is 16 bytes. RTS/CTS Hardware Flow Control This feature is for more flexible driver behavior.
Software Installation Smartio C168H/HS User ’s Manual 3-33 Terminal Emulation Th is ut il it y pr ov id es da ta se nd in g an d re ce iv ing ab il it y of a ll tt y po rt s, es pe ci al ly fo r MO XA po rt s.
3-34 Smartio C168H/HS User ’s Manual 2 Select and enter “Dumb Terminal” to enter terminal emulation. Or select and enter “Advance Transfer Modes” to perform pattern or file transfer with protocols such as ZModem.
Software Installation Smartio C168H/HS User ’s Manual 3-35 Setting MOXA Ports to Terminal Following procedure is how to set the MOXA port to the “Terminal” for login purpose, taking ttya11 as an example, SCO UNIX/OpenServer # enable /dev/ttye11 UNIX SVR4.
3-36 Smartio C168H/HS User ’s Manual.
Smartio C168H/HS User ’s Manual 4-1 4 4 4 Se ria l P r og ra mm ing To o ls Moxa supports easy but powerful serial programming library and communication troubleshooting utilities under Windows NT, Windows 95/98, UNIX and DOS. You will save greatly the developing time, using MOXA Serial Programming Tools.
4-2 Smartio C168H/HS User ’s Manual PCom m Programming Library The serial communication library is to assist users to develop programs for serial communications for any COM port complying with Microsoft Win32 API.
Serial Programming Tools Smartio C168H/HS User ’s Manual 4-3 Diagnostic (for MOXA boards only) A convenient diagnostic program provides internal and external testing, such as IRQ, TxD/RxD, UART, CTS/RTS, DTR/DSR, DTR/DCD testing, etc., for the MOXA boards and ports to verify correct operation of both the software and hardware.
4-4 Smartio C168H/HS User ’s Manual Monitor (for MOXA boards under Windows NT Only) A useful port status monitoring program allows you to watch the selected MOXA COM ports' data transmitting/receiving throughput and communication line status which are updated and displayed on the screen at every time interval.
Serial Programming Tools Smartio C168H/HS User ’s Manual 4-5 Terminal Emulator The Terminal Emulator features multi-windows and supports terminal types of VT100 and ANSI. You can transfer data interactively, send pattern periodically or transfer file using ASCII, XMODEM, YMODEM, ZMODEM and KERMIT protocols.
4-6 Smartio C168H/HS User ’s Manual UNIX Programming the MOXA Ports The system calls that apply to standard tty port can also be applied to MOXA port since MOXA port conforms to UNIX tty standard. System calls are like open(), ioctl(), read(), write(), close(), etc.
Serial Programming Tools Smartio C168H/HS User ’s Manual 4-7 Syntax for SCO UNIX/ OpenServer #define MIBUFED 0x401 int count; /* number of bytes queued in the buffer */ ioctl(moxa_fd, MIBUFED, &count); Syntax for UNIX SVR4.2 #include <sys/stropts.
4-8 Smartio C168H/HS User ’s Manual Syntax for UNIX SVR4.2 #include <sys/stropts.h> #include <sys/sysmacros.h> #define MOBUFED 0x402 struct strioctl ioc; int count; /* number of bytes queued in the output buffer */ ioc.ic_cmd = MOBUFED; ioc.
Serial Programming Tools Smartio C168H/HS User ’s Manual 4-9 setting = TurnON /* or TurnOFF */; ioc.ic_cmd = MTCRTS; ioc.ic_timout = 0; ioc.ic_len = sizeof(int); ioc.
4-10 Smartio C168H/HS User ’s Manual until the output buffer has 'enough space' again. The criteria to tell if the output buffer has 'enough space' is whether the output buffer reached its 'low water' level. That is the output buffer will accept further data only when the 'low water' level is reached.
Serial Programming Tools Smartio C168H/HS User ’s Manual 4-11 Syntax for SCO UNIX/ OpenServer #define MSTATUS 0x407 int status; /* status = RS-232 line status */ /* bit0 ¡Ð CTS (1:on, 0:off) */ /* bit1 ¡Ð DSR (1:on, 0:off) */ /* bit2 ¡Ð DCD (1:on, 0:off) */ ioctl(moxa_fd, MSTATUS, &status); Syntax for UNIX SVR4.
4-12 Smartio C168H/HS User ’s Manual Syntax for SCO UNIX/ OpenServer #define MHWFLOW 0x40e #define HWFlowControlOff 0x00 #define CTSFlowControlBitOn 0x01 #define RTSFlowControlBitOn 0x02 #define HWF.
Serial Programming Tools Smartio C168H/HS User ’s Manual 4-13 Utilities You can use the administration utility, moxaadm , to monitor port activity and to do terminal emulation , which are details as follows. Port Monitoring This utility gives you a quick view about all the MOXA ports' activities.
4-14 Smartio C168H/HS User ’s Manual Terminal Emulator Th is ut il it y pr ov id es da ta se nd in g an d re ce iv ing ab il it y of a ll tt y po rt s, es pe ci al ly fo r MO XA po rt s.
Serial Programming Tools Smartio C168H/HS User ’s Manual 4-15 2. Select and enter “Dumb Terminal” to enter terminal emulation. Or select and enter “Advance Transfer Modes” to perform pattern or file transfer with protocols such as ZModem. DOS Installation API-232 Library is the professional serial programming tool for DOS.
4-16 Smartio C168H/HS User ’s Manual Utilities There are two utilities available for DOS: Data Scope and Diagnose, which are detailed below. Data Scope The Data Scope, BINSCOPE.EXE , is a suite of utility programs that can help users with system troubleshooting and serial communication debugging.
Serial Programming Tools Smartio C168H/HS User ’s Manual 4-17 Pl ea se se e on -li ne he lp a s run ni ng BI N SC OPE .E XE f o r m or e us age a n d c ap ab il ity in fo rm at io n. Diagnose The Diagnose, BINDIAGNOSE.EXE , is a utility that can help users to diagnose the hardware condition of each port of the selected board.
4-18 Smartio C168H/HS User ’s Manual There are 2 solutions to control RS-485 2-wire transmission. Solution 1 The following model is common in RS-485 2-wire transmission. sio_SetWriteTimeouts(port, 0); /* Set sio_write() into block mode if for Windows NT and Windows 95/98 */ sio_RTS(port, 1); /* Turn on RTS signal.
Smartio C168H/HS User ’s Manual 5-1 5 5 5 Connection Option (Opt8x) and Cable Wiring In serial data communications, the term DTE is for Data Terminal Equipment like PC COM1/2, serial printer and terminal. The term DCE is for Data Communication Equipment like modem.
5-2 Smartio C168H/HS User ’s Manual The followings are pin assignments for various connection options: Opt8A/S (DCE, DB25 Female) 2 RxD 3 TxD 4 CTS 5 RTS 6 DTR 7 GND 8 DCD 20 DSR Opt8B/C (DTE, DB25 .
Connection Option (Opt8x) and Cable Wiring Smartio C168H/HS User ’s Manual 5-3 Type 1: To connect S m a r t i o C168 Series to a DTE device. PC COM2 port, Se rial Printe r, Term inal, or any DTE Dev.
5-4 Smartio C168H/HS User ’s Manual PC COM2 p ort, Se rial Printe r, Term inal, or any DTE Dev ice Opt8D Opt8D DTE Device DB9 Male DB25 Male RxD 2 2 TxD TxD 3 3 RxD CTS 8 4 RTS RTS 7 5 CTS DTR 4 6 DSR DSR 6 20 DTR GND 5 7 GND DCD 1 8 DCD Type 2: To connect S m a r t i o C168 Series to a DCE device.
Connection Option (Opt8x) and Cable Wiring Smartio C168H/HS User ’s Manual 5-5 Modem , or any DCE D evice Opt8B/C Straight-through Cable Opt8B/C DCE Device DB25 Male DB25 Female TxD 2 2 RxD RxD 3 3 .
5-6 Smartio C168H/HS User ’s Manual Type 3: To connect S m a r t i o C168 Series to a DTE with 3-pin wiring. If the “ Hardware flow control ” feature is set to “ ON ”, you must loop back (or short) the RTS with CTS and DSR with DTR, DCD on MOXA site, indicated in dash-lines of the following diagrams.
Connection Option (Opt8x) and Cable Wiring Smartio C168H/HS User ’s Manual 5-7 PC COM2 p ort, Se rial Printe r, Term inal, or any DTE Dev ice Opt8D Opt8D DTE Device DB9 Male DB25 Male RxD 2 2 TxD Tx.
5-8 Smartio C168H/HS User ’s Manual RS-422 Pinouts for Opt8J/F/Z: Opt8J/F/Z 2 RxD+(B) 3 TxD+(B) 14 RxD-(A) 16 TxD-(A) 7 GND 4 CTS+(B) 5 RTS+(B) 13 RTS-(A) Opt8J only 19 CTS-(A) The RS-422 transmission distance can reach as long as 4000ft. The connection box needs an external power adapter to supply 5V DC power.
Connection Option (Opt8x) and Cable Wiring Smartio C168H/HS User ’s Manual 5-9 The followings are operation modes for RS-422: RS-422 Point-to-point RS-422 Broadcasting Opt8J/F/Z RS-422 Device Opt8J/.
5-10 Smartio C168H/HS User ’s Manual RS-485 Cable Wiring for Opt8J One RS-485 connection box designed for Smartio C16 8 Series is: Opt8J: Connection box with 8 female RS-422/485 DB25 ports. Set the port switch to ON position (RS-485) for the desired port(s).
Connection Option (Opt8x) and Cable Wiring Smartio C168H/HS User ’s Manual 5-11 RS-422/485 Impedance Matching For RS-422/485 serial communications, when an electrical signal travels through two different resistance junctions in a transmission line, the impedance mismatch will sometimes cause signal reflection.
5-12 Smartio C168H/HS User ’s Manual.
Smartio C168H/HS User ’s Manual 6-1 6 6 6 Tr ou bl esh oo tin g Common Smartio C168 Series problems and possible solutions are listed below. If you still have problems, contact your dealer or Moxa for help. Or use the “ Problem Report Form ” at the end of this manual to report problems to your dealer at once for faster technical support.
6-2 Smartio C168H/HS User ’s Manual Software Causes and Solutions: a. Smartio C168 Series checks the line status (CTS) before it sends data out if the RTS/CTS flow control feature is set to “Enable ” in the configuration or application program. Please refer to the “Connection Cable and Cable Wiring” chapter for proper wiring.
Troubleshooting Smartio C168H/HS User ’s Manual 6-3 To configure the board, you need to know the board’s Configuration Access Port (CAP) address. Because the CAP address is the only channel, via which the Io- irq.exe can access to the board. The following procedure instructs user to recover once the CAP is unknown.
6-4 Smartio C168H/HS User ’s Manual Step 8. Power off the PC. OFF Step 9. Remove the jumper on position JP1. jumper JP1 Remove Step 10. Power on the PC. ON Windows NT This section is specific for troubleshooting under Windows NT. For general problems and solutions, please see the previous section, “General Troubleshooting”.
Troubleshooting Smartio C168H/HS User ’s Manual 6-5 a. Some partial decoded network board may interfere with our board. Please avoid from using 0x300 as I/O address for those network boards. b. Check hardware configuration of Smartio C168 Series board by IO- IRQ.
6-6 Smartio C168H/HS User ’s Manual addresses for each port, Interrupt Vector, IRQ, is identical to that of the driver. c. The I/O addresses may conflict with other devices, please change another set of I/O address such as I/O:0x280, Interrupt Vector:0x2C0.
Troubleshooting Smartio C168H/HS User ’s Manual 6-7 “Time out table overflow”: NCALL parameter too small. “File table overflow”: NFILE or NINODE parameter too small. “Region table overflow” : NREGION or NPROC parameter too small. 2. Under UNIXs, the newly rebuilt kernel could not boot.
6-8 Smartio C168H/HS User ’s Manual.
Smartio C168H/HS User ’s Manual A-1 A A p p p p e e n n d d i i x x A Tech nic al Re f er en ce Specifications v Bus interface: ISA (EISA compatible) v Number of ports: 8 v I/O address: 0x0000 ~ 0xFFFF v IRQ: 2, 3, 4, 5, 7, 10, 11, 12, 15 v Data bits: 5, 6, 7, 8 v Stop bits: 1, 1.
A-2 Smartio C168H/HS User ’s Manual Smartio C168 Series Windows NT 3 Windows 95/98 3 DOS 3 SCO UNIX/OpenServer 3 UNIX SVR4.2 3 Linux R SCO XENIX C QNX C FreeBSD C 3 : Driver supported by Moxa and sh.
Troubleshooting Smartio C168H/HS User ’s Manual A-3 PC I/O Port Address Map The following is the list of the I/O port addresses commonly used, which is good for preventing I/O address conflict when configuring Smartio C168 Series.
A-4 Smartio C168H/HS User ’s Manual DB62 Connector Pinouts The following lists the pin assignments of the DB62 connector on the bracket. Pin no. Signal Pin no.
Problem Report Form Sm ar t i o C168 Series Customer name: Company: Tel: Fax: Email: Date: 1. Moxa Product : Smartio C168 Series Model : o C168H o C168HS Serial Number : ___________ 2. Moxa Driver Version : ________________ 3. Moxa hardware settings : 3.
Return Procedure For product repair, exchange or refund, you must: v Provide evidence of original purchase v Fill out the Problem Report Form (PRF) as detailed as possible for shorter product repair time.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Moxa Technologies C168HS c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Moxa Technologies C168HS - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Moxa Technologies C168HS, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Moxa Technologies C168HS va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Moxa Technologies C168HS, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Moxa Technologies C168HS.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Moxa Technologies C168HS. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Moxa Technologies C168HS ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.