

TWO HANDLE THERMOSTATIC TUB/SHOWER FAUCET T3428, T3428CP, T3428CPM, T3428STV, T3428NLBL, T3428CGPC, T3428CGSA, T3429, T3429CP, T3429CPM, T3429STV, 3429NLBL, T3429CGPC, T3429CGSA, T3431, T3431CP, T3431CPM, T3431STV, T3431NLBL, T3431CGC, T3134CGSA
TAPING THEM TO THE FLOW HANDLE OR THE ESCUTCHEON.
BY
OF
TO A MAXIMUM WATER DISCHARGE TEMPERATURE OF
ºF. ANY CHANGE TO THIS SETTING MAY RAISE THE
DISCHARGE TEMPERATURE AND COULD CAUSE SCALDING.
CAUTION: Danger of scald injury. Valve can be recalibrated to
!
provide higher temperature water. This valve has been preset at the factory to provide a range of water temperatures. Any change in settings or water inlet conditions from those used during calibration at the factory may raise the outlet temperature and may cause scalding. The responsibility for the proper installation and any recalibration of this valve lies with the installer.

FLASHLIGHT
HEX WRENCH LLAVE HEXAGONAL
LINTERNA LAMPE DE POCHE
CLÉ HEXAGONALE
PHILLIPS SCREWDRIVER DESTORNILLADOR DE ESTRELLA TOURNEVIS À POINTE CRUCIFORME
TEFLON TAPE CINTA DE TEFLON
PLUMBER'S PUTTY MASILLA DE PLOMERO
RUBAN TÉFLON
MASTIC DE PLOMBIER
For Safety and ease of faucet installation, Moen recommends the use of these helpful tools.
Para la seguridad y facilidad de instalacion de la mezcladora, Moen recomienda las siguientes herramientas.
Par mesure de sécurité et pour faciliter l’installation, Moen suggère l’utilisation des outils suivants.
¿Preguntas durante la
Des questions lors de
Installation? 1-800-BUY-MOEN (1-800-289-6636) Toronto 905-829-3400
instalación? 1-800-BUY-MOEN (1-800-289-6636) Toronto 905-829-3400
l’installation?
Toronto : (905) 829-3400 Ailleurs au Canada :
Rest of Canada
Resto del Canadá
1 800 465-6130
1-800-465-6130
1-800-465-6130

INSTALL SHOWER ARM 1/2” copper lookout (pipe protruding from wall) must be 2” (50mm) min. to 3” (76mm) max. in length and be free of deep scratches, dents, kinks or bends. The cutoff end must be free of burrs inside and out. Use of a tubing cutter is recommended.
TO INSTALL SLIP FIT SHOWER ARM: Press and twist shower arm (2) onto the lookout upside down and tightly up against the wall. Tighten set screw with a 3/32” hex wrench until it just starts to bind. Turn shower arm upright into position against the wall and finish tightening the setscrew. DO NOT OVERTIGHTEN.
IF USING SHOWER ARM ADAPTER (3) - IPS to CC: Apply Teflon tape to thread and install into IPS connection. Tighten with 9/16” socket wrench; DO NOT use an open end wrench. Cut off 2-3” from finished wall surface. Use of a tubing cutter is recommended.
TO INSTALL SHOWERHEAD Wrap shower arm thread with teflon tape. Thread shower head onto shower arm. Tighten shower head using a wrench on the flats located on the shower ball. Hold shower arm with one hand while tightening.
2 3/4 - 3 3/4"
2 3/4 - 3 3/4 " 2 3/4 - 3 3/4 "
TUB SPOUT INSTALLATION 1/2” copper lookout (pipe protruding from wall) must be 2 3/4" (70mm) min. to 3 3/4" (95mm) max. in length and be free of deep scratches, dents, kinks or bends. The cutoff end must be free of burrs inside and out. Use of a tubing cutter is recommended.
DO NOT use an open end wrench. Cut off 2 3/4- 3 3/4” from finished wall surface. Use of a tubing cutter is recommended.
TO INSTALL SLIP FIT SPOUT: Press and twist tub spout (8) onto the lookout upside down and tightly up against the wall. Tighten set screw with a 3/32" hex wrench until it just starts to bind. Turn spout upright into position against the wall and finish tightening the set screw. DO NOT OVERTIGHTEN.
IF USING ADAPTER TO INSTALL SPOUT WITH IPS CONNECTION: Apply Teflon tape to thread and install into IPS connection. Tighten with 9/16” socket wrench.
2-3" 2-3" · Lookout Pipe · Finished Wall


ATTACH BASE ESCUTCHEON: 1. Turn off main hot and cold water supply to valve. 2. Turn temperature extension near top of valve body counter-clockwise until it stops (it may already be in the full counter-clockwise position). 3. Turn white flow extension near bottom of valve body clockwise until it stops (it may already be in the full clockwise position). 4. Place the base escutcheon (4) over the hole in shower wall with larger hole in
the base escutcheon surrounding the top threaded extension from the valve. The base escutcheon will be correctly oriented when the word “MOEN” is right side up. 5. Place the flat side of the two ring escutcheons (5) against the base escutcheon (4): one ring escutcheon over the temperature extension and one ring escutcheon over the white flow extension. At this point, the ring escutcheons and base escutcheon will be hanging from the threaded extensions on the valve body.

4. After splines start to engage, turn the lower shell of the temperature knob clockwise several turns while holding the rubber grip to prevent it from turning. This turning will thread the internal threads in the temperature knob onto the threads on the valve body. Continue turning the lower shell (you may release the rubber grip) until the lower shell compresses the ring escutcheon (5) against the base escutcheon (4). It is helpful to pull the lower shell towards you away from the shower wall as you turn it to keep the knob from disassembling. Note that as the temperature knob nears the base escutcheon, the base escutcheon and ring escutcheon will have to be shifted upwards so that the ring escutcheon is centered on the lower shell and the black plastic part extending from the bottom of the temperature knob fits within the hole in the base escutcheon. Tighten the lower shell hand-tight only. Verify that the “9” is still at the 12 o’clock position. This completes the attachment of the temperature knob.
Use your hand to center the ring escutcheon as the temperature knob is threaded onto valve stem.
ATTACH TEMPERATURE KNOB: 1. Confirm that the temperature extension near top of valve body is rotated fully counter- clockwise. 2. Align the temperature knob to the temperature extension with the number “9” on the grip ring turned upward to the 12 o’clock position. 3. Move the temperature knob (6) towards the temperature extension until the internal splines (projections on the inner diameter) in the temperature knob start to engage the external splines on the temperature extension.


Flow extension turned fully clockwise Use your hand to center the ring escutcheon as the handle is threaded onto valve stem.
ATTACH FLOW HANDLE: 1. Confirm that the white flow extension is turned fully clockwise. Align the flow handle (7) to the flow extension with the handle pointing downwards (6 o’clock position). 2. Move the flow handle towards the flow extension until the internal splines in the flow handle start to engage the external splines on the flow extension. 3. After the splines start to engage, turn the shell of the flow handle (7) clockwise several turns while holding the handle to prevent it from rotating. This turning will thread the internal threads in the flow handle onto the threads on the valve body. Continue turning the shell (you may release the handle) until it compresses the ring escutcheon (5) against the base escutcheon (4). It is helpful to pull the shell towards you (away from the shower wall) as you turn it to keep the knob from disassembling. Again, as the flow handle nears the base escutcheon, the ring escutcheon will have to be shifted upwards so that the ring escutcheon is centered on the lower shell. Tighten the shell hand-tight only. This completes the attachment of the flow handle. The valve trim is now completely assembled and is ready for operation.
TESTING FOR PROPER OPERATION: 1. Make sure the flow handle (7) is still in the full down 6 o’clock position. 2. Turn on the hot and cold water supplies. 3. Turn the temperature knob fully counterclockwise so the number “9” is in the vertical 12 o’clock position. The numbers represent increasing temperature. “9” is the hottest and “1” is the coldest. 4. Turn the flow handle counter-clockwise to start flow from the shower head or tub spout. 5. The thermostatic valve has a temperature range from 85°F (29°C) corresponding to the number “1” on the temperature knob to 115°F (46°C) corresponding to the number “9” on the temperature knob. If the temperature when the knob is set at “9” is not approximately 115°F (46°C), or if a hotter maximum temperature is desired, the temperature range can be recalibrated by following the instructions in the section “Recalibration Procedure.”
CAUTION: RISK OF SCALDING HAZARD The valve has been calibrated at the factory to provide a maximum water temperature of 115°F (46°C). Any significant variation in the calibration or any variation in the water supply temperatures (greater than 5°F or 3°C) from those used at the factory during the calibration procedure can result in water temperatures that present scalding dangers. Therefore, it is important to check the water temperature with the temperature knob set at “9” to determine the maximum temperature of the water. The responsibility for the proper installation and any recalibration of this valve lies with the installer. 6. Turn the water off by turning the flow handle fully clockwise.

Loosen and remove screw
RE-CALIBRATION PROCEDURE 1. To re-calibrate the valve, it is necessary to gain access to the spindle (located behind the temperature extension near the top of the valve). 2. Turn the temperature extension counter- clockwise until it stops. 3. Loosen and remove the screw in the center of the temperature extension by turning it counterclockwise. 4. Carefully remove the temperature extension without turning it or the spindle behind it. You have now accessed the spindle. 5. To increase the temperature, rotate the spindle counter-clockwise one or two spline(s) past the mark on the retaining nut. To decrease the temperature, rotate the spindle clockwise one or two spline(s) past the mark on the retaining nut. 6. Replace the temperature extension, positioned fully counter-clockwise with the tab as close as possible to the clockwise side of the pin in the retaining nut. This should be done without rotating the spindle. Do not install the screw at this time. 7. Turn the flow handle counter-clockwise to start the flow of water.
Increase temperature Decrease temperature
temperature extension in place
Spindle w/ temperature extension removed
![Page 8 of the Moen Faucet (INS235A) user manual — HELPLINE: 1 (800) BUY-MOEN [289-6636]](/cdn/reader/b1/b16f1a33c067df7ef16995e06679602fe8cb3b57fe4c09c93d0b1c22602e580b/images/page-8.webp?w=400)
Moen products have been manufactured under the highest standards of quality and workmanship. Moen warrants to the original consumer purchaser for as long as the original consumer purchaser owns their home (the “Warranty Period” for homeowners), that this faucet will be leak and drip-free during normal use and all parts and finishes of this faucet will be free from defects in material and manufacturing workmanship. All other purchasers (including purchasers for industrial, commercial and business use) are warranted for a period of 5 years from the original date of purchase (the “Warranty Period” for non-homeowners).
If this faucet should ever develop a leak or drip during the Warranty Period, Moen will FREE OF CHARGE provide the parts necessary to put the faucet back in good working condition and will replace FREE OF CHARGE, any part or finish that proves defective in material and manufacturing workmanship, under normal installation, use and service. Replacement parts may be obtained by calling 1-800-289-6636 (Canada 1-800-465-6130), or by writing to the address shown. Proof of purchase (original sales receipt) from the original consumer purchaser must accompany all warranty claims. Defects or damage caused by the use of other than genuine Moen parts are not covered by this warranty. This warranty is applicable only to faucets purchased after December 1995 and shall be effective from the date of purchase as shown on purchaser’s receipt.
This warranty is extensive in that it covers replacement of all defective parts and finishes. However, damage due to installation error, product abuse, product misuse, or use of cleaners containing abrasives, alcohol or other organic solvents, whether performed by a contractor, service company, or yourself, are excluded from this warranty. Moen will not be responsible for labor charges and/or damage incurred in installation, repair or replacement, nor for any indirect, incidental or consequential damages, losses, injury or costs of any nature relating to this faucet. Except as provided by law, this warranty is in lieu of and excludes all other warranties, conditions and guarantees, whether expressed or implied, statutory or otherwise, including without restriction those of merchantability or of fitness for use.
Some states, provinces and nations do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state, province to province, nation to nation. Moen will advise you of the procedure to follow in making warranty claims. Simply write to Moen Incorporated using the address below. Explain the defect and include proof of purchase and your name, address, area code and telephone number.
Faucets made of leaded brass alloys may contribute small amounts of lead to water that is allowed to stand in contact with the brass. The amount of lead contributed by any faucet is highest when the faucet is new. The following steps may reduce potential exposure to lead from faucets and other parts of the plumbing system:
In the U.S. call our toll free Helpline number for answers to any product, installation, or warranty questions.
o 91-800-84-345
Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.
Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.